ABAP Select data from SAP table OBJNRCOM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OBJNRCOM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OBJNRCOM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OBJNRCOM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OBJNRCOM TYPE STANDARD TABLE OF OBJNRCOM,
      WA_OBJNRCOM TYPE OBJNRCOM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OBJNRCOM> TYPE OBJNRCOM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OBJNRCOM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OBJNRCOM
  INTO TABLE IT_OBJNRCOM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OBJNRCOM
*  INTO TABLE @DATA(IT_OBJNRCOM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OBJNRCOM INDEX 1 INTO DATA(WA_OBJNRCOM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OBJNRCOM ASSIGNING <OBJNRCOM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OBJNRCOM>-FISCVAR = 1.
<OBJNRCOM>-FISCPER = 1.
<OBJNRCOM>-KOKRS = 1.
<OBJNRCOM>-OBJNR = 1.
<OBJNRCOM>-KOSTL = 1.
ENDLOOP.

LOOP AT IT_OBJNRCOM INTO WA_OBJNRCOM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OBJNRCOM-LSTAR, sy-vline,
WA_OBJNRCOM-AUFNR, sy-vline,
WA_OBJNRCOM-PRZNR, sy-vline,
WA_OBJNRCOM-KSTRG, sy-vline,
WA_OBJNRCOM-POSID, sy-vline,
WA_OBJNRCOM-PKSTL_BUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OBJNRCOM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OBJNRCOM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OBJNRCOM INTO WA_OBJNRCOM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI7, internal->external for field FISCPER CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_OBJNRCOM-FISCPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-FISCPER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit OBJEX, internal->external for field OBJNR CALL FUNCTION 'CONVERSION_EXIT_OBJEX_OUTPUT' EXPORTING input = WA_OBJNRCOM-OBJNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-OBJNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBJNRCOM-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBJNRCOM-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBJNRCOM-PRZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-PRZNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_OBJNRCOM-POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-POSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PKSTL_BUE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBJNRCOM-PKSTL_BUE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-PKSTL_BUE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DRVTP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBJNRCOM-DRVTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-DRVTP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBJNRCOM-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SKSTG CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_OBJNRCOM-SKSTG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-SKSTG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SKSTF CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_OBJNRCOM-SKSTF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-SKSTF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SKSTV CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_OBJNRCOM-SKSTV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBJNRCOM-SKSTV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OBJNRCOM_STR,
FISCVAR TYPE STRING,
FISCPER TYPE STRING,
KOKRS TYPE STRING,
OBJNR TYPE STRING,
KOSTL TYPE STRING,
LSTAR TYPE STRING,
AUFNR TYPE STRING,
PRZNR TYPE STRING,
KSTRG TYPE STRING,
POSID TYPE STRING,
PKSTL_BUE TYPE STRING,
CBRKE TYPE STRING,
CBRKI TYPE STRING,
CBART TYPE STRING,
DRVTP TYPE STRING,
WRTTP TYPE STRING,
VERSN TYPE STRING,
ELEMT TYPE STRING,
SKSTG TYPE STRING,
SKSTF TYPE STRING,
SKSTV TYPE STRING,
WAERS TYPE STRING,
CURTYPE TYPE STRING,
VALUTYP TYPE STRING,END OF T_EKKO_STR. DATA: WA_OBJNRCOM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OBJNRCOM_STR-FISCVAR sy-vline
WA_OBJNRCOM_STR-FISCPER sy-vline
WA_OBJNRCOM_STR-KOKRS sy-vline
WA_OBJNRCOM_STR-OBJNR sy-vline
WA_OBJNRCOM_STR-KOSTL sy-vline
WA_OBJNRCOM_STR-LSTAR sy-vline
WA_OBJNRCOM_STR-AUFNR sy-vline
WA_OBJNRCOM_STR-PRZNR sy-vline
WA_OBJNRCOM_STR-KSTRG sy-vline
WA_OBJNRCOM_STR-POSID sy-vline
WA_OBJNRCOM_STR-PKSTL_BUE sy-vline
WA_OBJNRCOM_STR-CBRKE sy-vline
WA_OBJNRCOM_STR-CBRKI sy-vline
WA_OBJNRCOM_STR-CBART sy-vline
WA_OBJNRCOM_STR-DRVTP sy-vline
WA_OBJNRCOM_STR-WRTTP sy-vline
WA_OBJNRCOM_STR-VERSN sy-vline
WA_OBJNRCOM_STR-ELEMT sy-vline
WA_OBJNRCOM_STR-SKSTG sy-vline
WA_OBJNRCOM_STR-SKSTF sy-vline
WA_OBJNRCOM_STR-SKSTV sy-vline
WA_OBJNRCOM_STR-WAERS sy-vline
WA_OBJNRCOM_STR-CURTYPE sy-vline
WA_OBJNRCOM_STR-VALUTYP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.