ABAP Select data from SAP table NSDM_V_MMIM_QN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP NSDM_V_MMIM_QN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to NSDM_V_MMIM_QN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the NSDM_V_MMIM_QN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_NSDM_V_MMIM_QN TYPE STANDARD TABLE OF NSDM_V_MMIM_QN,
      WA_NSDM_V_MMIM_QN TYPE NSDM_V_MMIM_QN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <NSDM_V_MMIM_QN> TYPE NSDM_V_MMIM_QN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_NSDM_V_MMIM_QN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM NSDM_V_MMIM_QN
  INTO TABLE IT_NSDM_V_MMIM_QN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM NSDM_V_MMIM_QN
*  INTO TABLE @DATA(IT_NSDM_V_MMIM_QN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_NSDM_V_MMIM_QN INDEX 1 INTO DATA(WA_NSDM_V_MMIM_QN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_NSDM_V_MMIM_QN ASSIGNING <NSDM_V_MMIM_QN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<NSDM_V_MMIM_QN>-MANDT = 1.
<NSDM_V_MMIM_QN>-MATNR = 1.
<NSDM_V_MMIM_QN>-WERKS = 1.
<NSDM_V_MMIM_QN>-LGORT = 1.
<NSDM_V_MMIM_QN>-CHARG = 1.
ENDLOOP.

LOOP AT IT_NSDM_V_MMIM_QN INTO WA_NSDM_V_MMIM_QN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_NSDM_V_MMIM_QN-SOBKZ, sy-vline,
WA_NSDM_V_MMIM_QN-PSPNR, sy-vline,
WA_NSDM_V_MMIM_QN-LFGJA, sy-vline,
WA_NSDM_V_MMIM_QN-LFMON, sy-vline,
WA_NSDM_V_MMIM_QN-KZILL, sy-vline,
WA_NSDM_V_MMIM_QN-KZILQ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_NSDM_V_MMIM_QN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_NSDM_V_MMIM_QN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_NSDM_V_MMIM_QN INTO WA_NSDM_V_MMIM_QN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_NSDM_V_MMIM_QN-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_V_MMIM_QN-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_NSDM_V_MMIM_QN-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_V_MMIM_QN-PSPNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_NSDM_V_MMIM_QN_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
SOBKZ TYPE STRING,
PSPNR TYPE STRING,
LFGJA TYPE STRING,
LFMON TYPE STRING,
KZILL TYPE STRING,
KZILQ TYPE STRING,
KZILS TYPE STRING,
KZVLL TYPE STRING,
KZVLQ TYPE STRING,
KZVLS TYPE STRING,
MTART TYPE STRING,
MATKL TYPE STRING,
ABCIN TYPE STRING,
LGPBE TYPE STRING,
LVORM TYPE STRING,
LABST TYPE STRING,
INSME TYPE STRING,
SPEME TYPE STRING,
EINME TYPE STRING,END OF T_EKKO_STR. DATA: WA_NSDM_V_MMIM_QN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_NSDM_V_MMIM_QN_STR-MANDT sy-vline
WA_NSDM_V_MMIM_QN_STR-MATNR sy-vline
WA_NSDM_V_MMIM_QN_STR-WERKS sy-vline
WA_NSDM_V_MMIM_QN_STR-LGORT sy-vline
WA_NSDM_V_MMIM_QN_STR-CHARG sy-vline
WA_NSDM_V_MMIM_QN_STR-SOBKZ sy-vline
WA_NSDM_V_MMIM_QN_STR-PSPNR sy-vline
WA_NSDM_V_MMIM_QN_STR-LFGJA sy-vline
WA_NSDM_V_MMIM_QN_STR-LFMON sy-vline
WA_NSDM_V_MMIM_QN_STR-KZILL sy-vline
WA_NSDM_V_MMIM_QN_STR-KZILQ sy-vline
WA_NSDM_V_MMIM_QN_STR-KZILS sy-vline
WA_NSDM_V_MMIM_QN_STR-KZVLL sy-vline
WA_NSDM_V_MMIM_QN_STR-KZVLQ sy-vline
WA_NSDM_V_MMIM_QN_STR-KZVLS sy-vline
WA_NSDM_V_MMIM_QN_STR-MTART sy-vline
WA_NSDM_V_MMIM_QN_STR-MATKL sy-vline
WA_NSDM_V_MMIM_QN_STR-ABCIN sy-vline
WA_NSDM_V_MMIM_QN_STR-LGPBE sy-vline
WA_NSDM_V_MMIM_QN_STR-LVORM sy-vline
WA_NSDM_V_MMIM_QN_STR-LABST sy-vline
WA_NSDM_V_MMIM_QN_STR-INSME sy-vline
WA_NSDM_V_MMIM_QN_STR-SPEME sy-vline
WA_NSDM_V_MMIM_QN_STR-EINME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.