ABAP Select data from SAP table NSDM_AGING_CHECK into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP NSDM_AGING_CHECK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to NSDM_AGING_CHECK. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the NSDM_AGING_CHECK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_NSDM_AGING_CHECK TYPE STANDARD TABLE OF NSDM_AGING_CHECK,
WA_NSDM_AGING_CHECK TYPE NSDM_AGING_CHECK,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <NSDM_AGING_CHECK> TYPE NSDM_AGING_CHECK.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_NSDM_AGING_CHECK.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM NSDM_AGING_CHECK
INTO TABLE IT_NSDM_AGING_CHECK.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM NSDM_AGING_CHECK
* INTO TABLE @DATA(IT_NSDM_AGING_CHECK2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_NSDM_AGING_CHECK INDEX 1 INTO DATA(WA_NSDM_AGING_CHECK2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_NSDM_AGING_CHECK ASSIGNING <NSDM_AGING_CHECK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<NSDM_AGING_CHECK>-MANDT = 1.
<NSDM_AGING_CHECK>-RUN_ID = 1.
<NSDM_AGING_CHECK>-ERROR_ID = 1.
<NSDM_AGING_CHECK>-USER_NAME = 1.
<NSDM_AGING_CHECK>-CHECK_DATE_TIME = 1.
ENDLOOP. LOOP AT IT_NSDM_AGING_CHECK INTO WA_NSDM_AGING_CHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_NSDM_AGING_CHECK-CHECKED_PLANT, sy-vline,
WA_NSDM_AGING_CHECK-CHECKED_MAT, sy-vline,
WA_NSDM_AGING_CHECK-ERROR_STATUS, sy-vline,
WA_NSDM_AGING_CHECK-ERROR_TYPE, sy-vline,
WA_NSDM_AGING_CHECK-MATBF, sy-vline,
WA_NSDM_AGING_CHECK-WERKS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_NSDM_AGING_CHECK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_NSDM_AGING_CHECK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_NSDM_AGING_CHECK INTO WA_NSDM_AGING_CHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field CHECKED_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-CHECKED_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-CHECKED_MAT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATBF CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-MATBF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-MATBF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIFNR_SID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-LIFNR_SID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-LIFNR_SID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MAT_KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-MAT_KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-MAT_KDAUF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSP, internal->external for field MAT_PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-MAT_PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-MAT_PSPNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KUNNR_SID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-KUNNR_SID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-KUNNR_SID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DISUB_OWNER_SID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-DISUB_OWNER_SID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-DISUB_OWNER_SID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ERFME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-ERFME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-ERFME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BPRME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-BPRME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-BPRME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BSTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-BSTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-BSTME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field LSMEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-LSMEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-LSMEH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field /CWM/MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-/CWM/MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-/CWM/MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field /CWM/ERFME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-/CWM/ERFME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-/CWM/ERFME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field /CWM/MEINS_SID CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_NSDM_AGING_CHECK-/CWM/MEINS_SID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_NSDM_AGING_CHECK-/CWM/MEINS_SID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_NSDM_AGING_CHECK_STR,
MANDT TYPE STRING,
RUN_ID TYPE STRING,
ERROR_ID TYPE STRING,
USER_NAME TYPE STRING,
CHECK_DATE_TIME TYPE STRING,
CHECKED_PLANT TYPE STRING,
CHECKED_MAT TYPE STRING,
ERROR_STATUS TYPE STRING,
ERROR_TYPE TYPE STRING,
MATBF TYPE STRING,
WERKS TYPE STRING,
LGORT_SID TYPE STRING,
CHARG_SID TYPE STRING,
LIFNR_SID TYPE STRING,
MAT_KDAUF TYPE STRING,
MAT_KDPOS TYPE STRING,
MAT_PSPNR TYPE STRING,
KUNNR_SID TYPE STRING,
SOBKZ TYPE STRING,
LBBSA_SID TYPE STRING,
DISUB_OWNER_SID TYPE STRING,
RESOURCENAME_SID TYPE STRING,
KZBWS TYPE STRING,
XOBEW TYPE STRING,
KALNR TYPE STRING,
WAERS TYPE STRING,
DMBTR TYPE STRING,
BNBTR TYPE STRING,
BUALT TYPE STRING,
DMBUM TYPE STRING,
EXBWR TYPE STRING,
VKWRT TYPE STRING,
EXVKW TYPE STRING,
SALK3 TYPE STRING,
VKWRA TYPE STRING,
J_1BEXBASE TYPE STRING,
STOCK_VKWRT TYPE STRING,
DMBTR_STOCK TYPE STRING,
DMBTR_CONS TYPE STRING,
MEINS TYPE STRING,
MENGE TYPE STRING,
LBKUM TYPE STRING,
STOCK_QTY TYPE STRING,
CONSUMPTION_QTY TYPE STRING,
ERFME TYPE STRING,
ERFMG TYPE STRING,
BPRME TYPE STRING,
BPMNG TYPE STRING,
BSTME TYPE STRING,
BSTMG TYPE STRING,
LSMEH TYPE STRING,
LSMNG TYPE STRING,
PBAMG TYPE STRING,
CURRENCY_A1 TYPE STRING,
PRICE_A1 TYPE STRING,
PRICE_SOURCE_A1 TYPE STRING,
STOCK_VALUE_A1 TYPE STRING,
CONS_VALUE_A1 TYPE STRING,
/CWM/MENGE TYPE STRING,
/CWM/MEINS TYPE STRING,
/CWM/ERFMG TYPE STRING,
/CWM/ERFME TYPE STRING,
/CWM/STOCK_QTY TYPE STRING,
/CWM/CONSUMPTION_QTY TYPE STRING,
/CWM/MEINS_SID TYPE STRING,
BUDAT TYPE STRING,
MATDOC_MAX_DATA_TEMPERATURE TYPE STRING,
STATS_MAX_DATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_NSDM_AGING_CHECK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_NSDM_AGING_CHECK_STR-MANDT sy-vline
WA_NSDM_AGING_CHECK_STR-RUN_ID sy-vline
WA_NSDM_AGING_CHECK_STR-ERROR_ID sy-vline
WA_NSDM_AGING_CHECK_STR-USER_NAME sy-vline
WA_NSDM_AGING_CHECK_STR-CHECK_DATE_TIME sy-vline
WA_NSDM_AGING_CHECK_STR-CHECKED_PLANT sy-vline
WA_NSDM_AGING_CHECK_STR-CHECKED_MAT sy-vline
WA_NSDM_AGING_CHECK_STR-ERROR_STATUS sy-vline
WA_NSDM_AGING_CHECK_STR-ERROR_TYPE sy-vline
WA_NSDM_AGING_CHECK_STR-MATBF sy-vline
WA_NSDM_AGING_CHECK_STR-WERKS sy-vline
WA_NSDM_AGING_CHECK_STR-LGORT_SID sy-vline
WA_NSDM_AGING_CHECK_STR-CHARG_SID sy-vline
WA_NSDM_AGING_CHECK_STR-LIFNR_SID sy-vline
WA_NSDM_AGING_CHECK_STR-MAT_KDAUF sy-vline
WA_NSDM_AGING_CHECK_STR-MAT_KDPOS sy-vline
WA_NSDM_AGING_CHECK_STR-MAT_PSPNR sy-vline
WA_NSDM_AGING_CHECK_STR-KUNNR_SID sy-vline
WA_NSDM_AGING_CHECK_STR-SOBKZ sy-vline
WA_NSDM_AGING_CHECK_STR-LBBSA_SID sy-vline
WA_NSDM_AGING_CHECK_STR-DISUB_OWNER_SID sy-vline
WA_NSDM_AGING_CHECK_STR-RESOURCENAME_SID sy-vline
WA_NSDM_AGING_CHECK_STR-KZBWS sy-vline
WA_NSDM_AGING_CHECK_STR-XOBEW sy-vline
WA_NSDM_AGING_CHECK_STR-KALNR sy-vline
WA_NSDM_AGING_CHECK_STR-WAERS sy-vline
WA_NSDM_AGING_CHECK_STR-DMBTR sy-vline
WA_NSDM_AGING_CHECK_STR-BNBTR sy-vline
WA_NSDM_AGING_CHECK_STR-BUALT sy-vline
WA_NSDM_AGING_CHECK_STR-DMBUM sy-vline
WA_NSDM_AGING_CHECK_STR-EXBWR sy-vline
WA_NSDM_AGING_CHECK_STR-VKWRT sy-vline
WA_NSDM_AGING_CHECK_STR-EXVKW sy-vline
WA_NSDM_AGING_CHECK_STR-SALK3 sy-vline
WA_NSDM_AGING_CHECK_STR-VKWRA sy-vline
WA_NSDM_AGING_CHECK_STR-J_1BEXBASE sy-vline
WA_NSDM_AGING_CHECK_STR-STOCK_VKWRT sy-vline
WA_NSDM_AGING_CHECK_STR-DMBTR_STOCK sy-vline
WA_NSDM_AGING_CHECK_STR-DMBTR_CONS sy-vline
WA_NSDM_AGING_CHECK_STR-MEINS sy-vline
WA_NSDM_AGING_CHECK_STR-MENGE sy-vline
WA_NSDM_AGING_CHECK_STR-LBKUM sy-vline
WA_NSDM_AGING_CHECK_STR-STOCK_QTY sy-vline
WA_NSDM_AGING_CHECK_STR-CONSUMPTION_QTY sy-vline
WA_NSDM_AGING_CHECK_STR-ERFME sy-vline
WA_NSDM_AGING_CHECK_STR-ERFMG sy-vline
WA_NSDM_AGING_CHECK_STR-BPRME sy-vline
WA_NSDM_AGING_CHECK_STR-BPMNG sy-vline
WA_NSDM_AGING_CHECK_STR-BSTME sy-vline
WA_NSDM_AGING_CHECK_STR-BSTMG sy-vline
WA_NSDM_AGING_CHECK_STR-LSMEH sy-vline
WA_NSDM_AGING_CHECK_STR-LSMNG sy-vline
WA_NSDM_AGING_CHECK_STR-PBAMG sy-vline
WA_NSDM_AGING_CHECK_STR-CURRENCY_A1 sy-vline
WA_NSDM_AGING_CHECK_STR-PRICE_A1 sy-vline
WA_NSDM_AGING_CHECK_STR-PRICE_SOURCE_A1 sy-vline
WA_NSDM_AGING_CHECK_STR-STOCK_VALUE_A1 sy-vline
WA_NSDM_AGING_CHECK_STR-CONS_VALUE_A1 sy-vline
WA_NSDM_AGING_CHECK_STR-/CWM/MENGE sy-vline
WA_NSDM_AGING_CHECK_STR-/CWM/MEINS sy-vline
WA_NSDM_AGING_CHECK_STR-/CWM/ERFMG sy-vline
WA_NSDM_AGING_CHECK_STR-/CWM/ERFME sy-vline
WA_NSDM_AGING_CHECK_STR-/CWM/STOCK_QTY sy-vline
WA_NSDM_AGING_CHECK_STR-/CWM/CONSUMPTION_QTY sy-vline
WA_NSDM_AGING_CHECK_STR-/CWM/MEINS_SID sy-vline
WA_NSDM_AGING_CHECK_STR-BUDAT sy-vline
WA_NSDM_AGING_CHECK_STR-MATDOC_MAX_DATA_TEMPERATURE sy-vline
WA_NSDM_AGING_CHECK_STR-STATS_MAX_DATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
