ABAP Select data from SAP table MYML1V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MYML1V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MYML1V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MYML1V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MYML1V TYPE STANDARD TABLE OF MYML1V,
      WA_MYML1V TYPE MYML1V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MYML1V> TYPE MYML1V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MYML1V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MYML1V
  INTO TABLE IT_MYML1V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MYML1V
*  INTO TABLE @DATA(IT_MYML1V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MYML1V INDEX 1 INTO DATA(WA_MYML1V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MYML1V ASSIGNING <MYML1V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MYML1V>-MANDT = 1.
<MYML1V>-MYVER = 1.
<MYML1V>-MYKEY = 1.
<MYML1V>-MATNR = 1.
<MYML1V>-MBLNR = 1.
ENDLOOP.

LOOP AT IT_MYML1V INTO WA_MYML1V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MYML1V-MJAHR, sy-vline,
WA_MYML1V-MBLPO, sy-vline,
WA_MYML1V-CURTP, sy-vline,
WA_MYML1V-MYWRT, sy-vline,
WA_MYML1V-MYWRN, sy-vline,
WA_MYML1V-WAERS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MYML1V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MYML1V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MYML1V INTO WA_MYML1V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MYML1V-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MYML1V-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MYML1V-MBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MYML1V-MBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field MJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_MYML1V-MJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MYML1V-MJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MYML1V_STR,
MANDT TYPE STRING,
MYVER TYPE STRING,
MYKEY TYPE STRING,
MATNR TYPE STRING,
MBLNR TYPE STRING,
MJAHR TYPE STRING,
MBLPO TYPE STRING,
CURTP TYPE STRING,
MYWRT TYPE STRING,
MYWRN TYPE STRING,
WAERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_MYML1V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MYML1V_STR-MANDT sy-vline
WA_MYML1V_STR-MYVER sy-vline
WA_MYML1V_STR-MYKEY sy-vline
WA_MYML1V_STR-MATNR sy-vline
WA_MYML1V_STR-MBLNR sy-vline
WA_MYML1V_STR-MJAHR sy-vline
WA_MYML1V_STR-MBLPO sy-vline
WA_MYML1V_STR-CURTP sy-vline
WA_MYML1V_STR-MYWRT sy-vline
WA_MYML1V_STR-MYWRN sy-vline
WA_MYML1V_STR-WAERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.