ABAP Select data from SAP table MV08A_SKVB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MV08A_SKVB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MV08A_SKVB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MV08A_SKVB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MV08A_SKVB TYPE STANDARD TABLE OF MV08A_SKVB,
      WA_MV08A_SKVB TYPE MV08A_SKVB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MV08A_SKVB> TYPE MV08A_SKVB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MV08A_SKVB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MV08A_SKVB
  INTO TABLE IT_MV08A_SKVB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MV08A_SKVB
*  INTO TABLE @DATA(IT_MV08A_SKVB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MV08A_SKVB INDEX 1 INTO DATA(WA_MV08A_SKVB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MV08A_SKVB ASSIGNING <MV08A_SKVB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MV08A_SKVB>-MANDT = 1.
<MV08A_SKVB>-SAMMG = 1.
<MV08A_SKVB>-SMART = 1.
<MV08A_SKVB>-ERNAM = 1.
<MV08A_SKVB>-ERDAT = 1.
ENDLOOP.

LOOP AT IT_MV08A_SKVB INTO WA_MV08A_SKVB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MV08A_SKVB-UZEIT, sy-vline,
WA_MV08A_SKVB-VBNUM, sy-vline,
WA_MV08A_SKVB-ERNUM, sy-vline,
WA_MV08A_SKVB-BRGEW, sy-vline,
WA_MV08A_SKVB-GEWEI, sy-vline,
WA_MV08A_SKVB-VOLUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MV08A_SKVB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MV08A_SKVB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MV08A_SKVB INTO WA_MV08A_SKVB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAMMG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MV08A_SKVB-SAMMG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MV08A_SKVB-SAMMG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MV08A_SKVB-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MV08A_SKVB-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MV08A_SKVB-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MV08A_SKVB-VOLEH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MV08A_SKVB_STR,
MANDT TYPE STRING,
SAMMG TYPE STRING,
SMART TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
UZEIT TYPE STRING,
VBNUM TYPE STRING,
ERNUM TYPE STRING,
BRGEW TYPE STRING,
GEWEI TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
VSTEL TYPE STRING,
VTEXT TYPE STRING,
MAXZT TYPE STRING,
PROGRAMM TYPE STRING,
SELSET TYPE STRING,
BATCH TYPE STRING,
ANZLP TYPE STRING,
ANZGP TYPE STRING,
ANZGI TYPE STRING,
KWPRO TYPE STRING,
KAPTP TYPE STRING,
LGNUM TYPE STRING,
BEDAT TYPE STRING,
WRAST TYPE STRING,
COLLECTIVERUN_UUID TYPE STRING,
INDICATOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_MV08A_SKVB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MV08A_SKVB_STR-MANDT sy-vline
WA_MV08A_SKVB_STR-SAMMG sy-vline
WA_MV08A_SKVB_STR-SMART sy-vline
WA_MV08A_SKVB_STR-ERNAM sy-vline
WA_MV08A_SKVB_STR-ERDAT sy-vline
WA_MV08A_SKVB_STR-UZEIT sy-vline
WA_MV08A_SKVB_STR-VBNUM sy-vline
WA_MV08A_SKVB_STR-ERNUM sy-vline
WA_MV08A_SKVB_STR-BRGEW sy-vline
WA_MV08A_SKVB_STR-GEWEI sy-vline
WA_MV08A_SKVB_STR-VOLUM sy-vline
WA_MV08A_SKVB_STR-VOLEH sy-vline
WA_MV08A_SKVB_STR-VSTEL sy-vline
WA_MV08A_SKVB_STR-VTEXT sy-vline
WA_MV08A_SKVB_STR-MAXZT sy-vline
WA_MV08A_SKVB_STR-PROGRAMM sy-vline
WA_MV08A_SKVB_STR-SELSET sy-vline
WA_MV08A_SKVB_STR-BATCH sy-vline
WA_MV08A_SKVB_STR-ANZLP sy-vline
WA_MV08A_SKVB_STR-ANZGP sy-vline
WA_MV08A_SKVB_STR-ANZGI sy-vline
WA_MV08A_SKVB_STR-KWPRO sy-vline
WA_MV08A_SKVB_STR-KAPTP sy-vline
WA_MV08A_SKVB_STR-LGNUM sy-vline
WA_MV08A_SKVB_STR-BEDAT sy-vline
WA_MV08A_SKVB_STR-WRAST sy-vline
WA_MV08A_SKVB_STR-COLLECTIVERUN_UUID sy-vline
WA_MV08A_SKVB_STR-INDICATOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.