ABAP Select data from SAP table MPES_STPO_LINKS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_STPO_LINKS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_STPO_LINKS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_STPO_LINKS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_STPO_LINKS TYPE STANDARD TABLE OF MPES_STPO_LINKS,
      WA_MPES_STPO_LINKS TYPE MPES_STPO_LINKS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_STPO_LINKS> TYPE MPES_STPO_LINKS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_STPO_LINKS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_STPO_LINKS
  INTO TABLE IT_MPES_STPO_LINKS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_STPO_LINKS
*  INTO TABLE @DATA(IT_MPES_STPO_LINKS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_STPO_LINKS INDEX 1 INTO DATA(WA_MPES_STPO_LINKS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_STPO_LINKS ASSIGNING <MPES_STPO_LINKS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_STPO_LINKS>-MANDT = 1.
<MPES_STPO_LINKS>-LINK = 1.
<MPES_STPO_LINKS>-EBOM_STLTY = 1.
<MPES_STPO_LINKS>-EBOM_STLNR = 1.
<MPES_STPO_LINKS>-EBOM_STLAL = 1.
ENDLOOP.

LOOP AT IT_MPES_STPO_LINKS INTO WA_MPES_STPO_LINKS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_STPO_LINKS-EBOM_STVKN, sy-vline,
WA_MPES_STPO_LINKS-EBOM_VERSN, sy-vline,
WA_MPES_STPO_LINKS-MBOM_STLTY, sy-vline,
WA_MPES_STPO_LINKS-MBOM_STLNR, sy-vline,
WA_MPES_STPO_LINKS-MBOM_STLAL, sy-vline,
WA_MPES_STPO_LINKS-MBOM_STVKN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_STPO_LINKS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_STPO_LINKS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_STPO_LINKS INTO WA_MPES_STPO_LINKS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field EBOM_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_STPO_LINKS-EBOM_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_STPO_LINKS-EBOM_STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBOM_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_STPO_LINKS-EBOM_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_STPO_LINKS-EBOM_STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field MBOM_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_STPO_LINKS-MBOM_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_STPO_LINKS-MBOM_STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MBOM_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_STPO_LINKS-MBOM_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_STPO_LINKS-MBOM_STLAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_STPO_LINKS_STR,
MANDT TYPE STRING,
LINK TYPE STRING,
EBOM_STLTY TYPE STRING,
EBOM_STLNR TYPE STRING,
EBOM_STLAL TYPE STRING,
EBOM_STVKN TYPE STRING,
EBOM_VERSN TYPE STRING,
MBOM_STLTY TYPE STRING,
MBOM_STLNR TYPE STRING,
MBOM_STLAL TYPE STRING,
MBOM_STVKN TYPE STRING,
MBOM_VERSN TYPE STRING,
VARIANT_GUID TYPE STRING,
ENG_SOURCE TYPE STRING,
ENGINEERING_ONLY TYPE STRING,
NODE TYPE STRING,
INT_NODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_STPO_LINKS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_STPO_LINKS_STR-MANDT sy-vline
WA_MPES_STPO_LINKS_STR-LINK sy-vline
WA_MPES_STPO_LINKS_STR-EBOM_STLTY sy-vline
WA_MPES_STPO_LINKS_STR-EBOM_STLNR sy-vline
WA_MPES_STPO_LINKS_STR-EBOM_STLAL sy-vline
WA_MPES_STPO_LINKS_STR-EBOM_STVKN sy-vline
WA_MPES_STPO_LINKS_STR-EBOM_VERSN sy-vline
WA_MPES_STPO_LINKS_STR-MBOM_STLTY sy-vline
WA_MPES_STPO_LINKS_STR-MBOM_STLNR sy-vline
WA_MPES_STPO_LINKS_STR-MBOM_STLAL sy-vline
WA_MPES_STPO_LINKS_STR-MBOM_STVKN sy-vline
WA_MPES_STPO_LINKS_STR-MBOM_VERSN sy-vline
WA_MPES_STPO_LINKS_STR-VARIANT_GUID sy-vline
WA_MPES_STPO_LINKS_STR-ENG_SOURCE sy-vline
WA_MPES_STPO_LINKS_STR-ENGINEERING_ONLY sy-vline
WA_MPES_STPO_LINKS_STR-NODE sy-vline
WA_MPES_STPO_LINKS_STR-INT_NODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.