ABAP Select data from SAP table MPES_RTGV_WORK_INSTRUCTION_BO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_RTGV_WORK_INSTRUCTION_BO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_RTGV_WORK_INSTRUCTION_BO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_RTGV_WORK_INSTRUCTION_BO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_RTGV_WORK_INSTRUCTION_BO TYPE STANDARD TABLE OF MPES_RTGV_WORK_INSTRUCTION_BO,
      WA_MPES_RTGV_WORK_INSTRUCTION_BO TYPE MPES_RTGV_WORK_INSTRUCTION_BO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_RTGV_WORK_INSTRUCTION_BO> TYPE MPES_RTGV_WORK_INSTRUCTION_BO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_RTGV_WORK_INSTRUCTION_BO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_RTGV_WORK_INSTRUCTION_BO
  INTO TABLE IT_MPES_RTGV_WORK_INSTRUCTION_BO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_RTGV_WORK_INSTRUCTION_BO
*  INTO TABLE @DATA(IT_MPES_RTGV_WORK_INSTRUCTION_BO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_RTGV_WORK_INSTRUCTION_BO INDEX 1 INTO DATA(WA_MPES_RTGV_WORK_INSTRUCTION_BO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_RTGV_WORK_INSTRUCTION_BO ASSIGNING <MPES_RTGV_WORK_INSTRUCTION_BO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_RTGV_WORK_INSTRUCTION_BO>-PLNTY = 1.
<MPES_RTGV_WORK_INSTRUCTION_BO>-PLNNR = 1.
<MPES_RTGV_WORK_INSTRUCTION_BO>-PLNAL = 1.
<MPES_RTGV_WORK_INSTRUCTION_BO>-VERSN = 1.
<MPES_RTGV_WORK_INSTRUCTION_BO>-PLNFL = 1.
ENDLOOP.

LOOP AT IT_MPES_RTGV_WORK_INSTRUCTION_BO INTO WA_MPES_RTGV_WORK_INSTRUCTION_BO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_RTGV_WORK_INSTRUCTION_BO-PLNKN, sy-vline,
WA_MPES_RTGV_WORK_INSTRUCTION_BO-SEGMENT_TYPE, sy-vline,
WA_MPES_RTGV_WORK_INSTRUCTION_BO-OA_ID, sy-vline,
WA_MPES_RTGV_WORK_INSTRUCTION_BO-OA_VERSION_NO, sy-vline,
WA_MPES_RTGV_WORK_INSTRUCTION_BO-SPRAS, sy-vline,
WA_MPES_RTGV_WORK_INSTRUCTION_BO-WI_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_RTGV_WORK_INSTRUCTION_BO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_RTGV_WORK_INSTRUCTION_BO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_RTGV_WORK_INSTRUCTION_BO INTO WA_MPES_RTGV_WORK_INSTRUCTION_BO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_WORK_INSTRUCTION_BO-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_WORK_INSTRUCTION_BO-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_WORK_INSTRUCTION_BO-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_WORK_INSTRUCTION_BO-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_WORK_INSTRUCTION_BO-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_WORK_INSTRUCTION_BO-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_WORK_INSTRUCTION_BO-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_WORK_INSTRUCTION_BO-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_MPES_RTGV_WORK_INSTRUCTION_BO-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_WORK_INSTRUCTION_BO-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_RTGV_WORK_INSTRUCTION_BO_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
VERSN TYPE STRING,
PLNFL TYPE STRING,
PLNKN TYPE STRING,
SEGMENT_TYPE TYPE STRING,
OA_ID TYPE STRING,
OA_VERSION_NO TYPE STRING,
SPRAS TYPE STRING,
WI_ID TYPE STRING,
WI_VERSION_NO TYPE STRING,
WI_RELEASE TYPE STRING,
WI_MODE TYPE STRING,
WI_CONTENT_UUID TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
CREA_DATE_TIME TYPE STRING,
CREA_UNAME TYPE STRING,
LCHG_DATE_TIME TYPE STRING,
LCHG_UNAME TYPE STRING,
WI_CONTENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-PLNTY sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-PLNNR sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-PLNAL sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-VERSN sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-PLNFL sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-PLNKN sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-SEGMENT_TYPE sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-OA_ID sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-OA_VERSION_NO sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-SPRAS sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-WI_ID sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-WI_VERSION_NO sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-WI_RELEASE sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-WI_MODE sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-WI_CONTENT_UUID sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-CREATED_BY sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-CREATED_AT sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-CHANGED_BY sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-CHANGED_AT sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-CREA_DATE_TIME sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-CREA_UNAME sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-LCHG_DATE_TIME sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-LCHG_UNAME sy-vline
WA_MPES_RTGV_WORK_INSTRUCTION_BO_STR-WI_CONTENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.