ABAP Select data from SAP table MPES_RTGV_PROD_VERS_DETAIL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_RTGV_PROD_VERS_DETAIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_RTGV_PROD_VERS_DETAIL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_RTGV_PROD_VERS_DETAIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_RTGV_PROD_VERS_DETAIL TYPE STANDARD TABLE OF MPES_RTGV_PROD_VERS_DETAIL,
      WA_MPES_RTGV_PROD_VERS_DETAIL TYPE MPES_RTGV_PROD_VERS_DETAIL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_RTGV_PROD_VERS_DETAIL> TYPE MPES_RTGV_PROD_VERS_DETAIL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_RTGV_PROD_VERS_DETAIL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_RTGV_PROD_VERS_DETAIL
  INTO TABLE IT_MPES_RTGV_PROD_VERS_DETAIL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_RTGV_PROD_VERS_DETAIL
*  INTO TABLE @DATA(IT_MPES_RTGV_PROD_VERS_DETAIL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_RTGV_PROD_VERS_DETAIL INDEX 1 INTO DATA(WA_MPES_RTGV_PROD_VERS_DETAIL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_RTGV_PROD_VERS_DETAIL ASSIGNING <MPES_RTGV_PROD_VERS_DETAIL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_RTGV_PROD_VERS_DETAIL>-GUID = 1.
<MPES_RTGV_PROD_VERS_DETAIL>-MATNR = 1.
<MPES_RTGV_PROD_VERS_DETAIL>-WERKS = 1.
<MPES_RTGV_PROD_VERS_DETAIL>-VERID = 1.
<MPES_RTGV_PROD_VERS_DETAIL>-TEXT1 = 1.
ENDLOOP.

LOOP AT IT_MPES_RTGV_PROD_VERS_DETAIL INTO WA_MPES_RTGV_PROD_VERS_DETAIL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_RTGV_PROD_VERS_DETAIL-PLNTY, sy-vline,
WA_MPES_RTGV_PROD_VERS_DETAIL-PLNNR, sy-vline,
WA_MPES_RTGV_PROD_VERS_DETAIL-ALNAL, sy-vline,
WA_MPES_RTGV_PROD_VERS_DETAIL-STLTY, sy-vline,
WA_MPES_RTGV_PROD_VERS_DETAIL-STLAN, sy-vline,
WA_MPES_RTGV_PROD_VERS_DETAIL-STLNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_RTGV_PROD_VERS_DETAIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_RTGV_PROD_VERS_DETAIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_RTGV_PROD_VERS_DETAIL INTO WA_MPES_RTGV_PROD_VERS_DETAIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-ALNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-ALNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field EXE_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXE_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXE_PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXE_ALNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_ALNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-EXE_ALNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PLNME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_PROD_VERS_DETAIL-PLNME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_PROD_VERS_DETAIL-PLNME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_RTGV_PROD_VERS_DETAIL_STR,
GUID TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
VERID TYPE STRING,
TEXT1 TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
ALNAL TYPE STRING,
STLTY TYPE STRING,
STLAN TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
BSTMI TYPE STRING,
BSTMA TYPE STRING,
ADATU TYPE STRING,
BDATU TYPE STRING,
MKSP TYPE STRING,
ASSIGNED TYPE STRING,
EXE_STLTY TYPE STRING,
EXE_STLAN TYPE STRING,
EXE_STLNR TYPE STRING,
EXE_STLAL TYPE STRING,
EXE_PLNTY TYPE STRING,
EXE_PLNNR TYPE STRING,
EXE_ALNAL TYPE STRING,
DRAFT_GUID TYPE STRING,
DIFFPLANEXEMSTR TYPE STRING,
STLAN_TEXT TYPE STRING,
EXE_STLAN_TEXT TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,
BOM_VERSN TYPE STRING,
VERSN TYPE STRING,
ZUONR TYPE STRING,
PLNAL TYPE STRING,
PLNME TYPE STRING,
KTEXT TYPE STRING,
MATNR_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_RTGV_PROD_VERS_DETAIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-GUID sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-MATNR sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-WERKS sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-VERID sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-TEXT1 sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-PLNTY sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-PLNNR sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-ALNAL sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-STLTY sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-STLAN sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-STLNR sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-STLAL sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-BSTMI sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-BSTMA sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-ADATU sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-BDATU sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-MKSP sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-ASSIGNED sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_STLTY sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_STLAN sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_STLNR sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_STLAL sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_PLNTY sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_PLNNR sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_ALNAL sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-DRAFT_GUID sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-DIFFPLANEXEMSTR sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-STLAN_TEXT sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-EXE_STLAN_TEXT sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-VALIDITYSTARTDATE sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-VALIDITYENDDATE sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-BOM_VERSN sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-VERSN sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-ZUONR sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-PLNAL sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-PLNME sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-KTEXT sy-vline
WA_MPES_RTGV_PROD_VERS_DETAIL_STR-MATNR_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.