ABAP Select data from SAP table MPES_RTGV_OPR_BO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_RTGV_OPR_BO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_RTGV_OPR_BO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_RTGV_OPR_BO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_RTGV_OPR_BO TYPE STANDARD TABLE OF MPES_RTGV_OPR_BO,
      WA_MPES_RTGV_OPR_BO TYPE MPES_RTGV_OPR_BO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_RTGV_OPR_BO> TYPE MPES_RTGV_OPR_BO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_RTGV_OPR_BO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_RTGV_OPR_BO
  INTO TABLE IT_MPES_RTGV_OPR_BO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_RTGV_OPR_BO
*  INTO TABLE @DATA(IT_MPES_RTGV_OPR_BO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_RTGV_OPR_BO INDEX 1 INTO DATA(WA_MPES_RTGV_OPR_BO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_RTGV_OPR_BO ASSIGNING <MPES_RTGV_OPR_BO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_RTGV_OPR_BO>-PLNTY = 1.
<MPES_RTGV_OPR_BO>-PLNNR = 1.
<MPES_RTGV_OPR_BO>-PLNAL = 1.
<MPES_RTGV_OPR_BO>-VERSN = 1.
<MPES_RTGV_OPR_BO>-PLNFL = 1.
ENDLOOP.

LOOP AT IT_MPES_RTGV_OPR_BO INTO WA_MPES_RTGV_OPR_BO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_RTGV_OPR_BO-PLNKN, sy-vline,
WA_MPES_RTGV_OPR_BO-DATUV, sy-vline,
WA_MPES_RTGV_OPR_BO-DATUB, sy-vline,
WA_MPES_RTGV_OPR_BO-VERSN_SOURCE, sy-vline,
WA_MPES_RTGV_OPR_BO-VERSN_SOURCE_PLNKN, sy-vline,
WA_MPES_RTGV_OPR_BO-VERSN_TRACK_GUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_RTGV_OPR_BO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_RTGV_OPR_BO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_RTGV_OPR_BO INTO WA_MPES_RTGV_OPR_BO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN_SOURCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VERSN_SOURCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VERSN_SOURCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR_REFT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNNR_REFT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNNR_REFT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL_REFT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNAL_REFT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNAL_REFT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN_REFT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VERSN_REFT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VERSN_REFT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL_REFT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNFL_REFT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNFL_REFT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR_REFT_OLD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNNR_REFT_OLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNNR_REFT_OLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL_REFT_OLD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNAL_REFT_OLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNAL_REFT_OLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN_REFT_OLD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VERSN_REFT_OLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VERSN_REFT_OLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL_REFT_OLD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNFL_REFT_OLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNFL_REFT_OLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIER CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE01 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VGE01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VGE01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE02 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VGE02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VGE02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE03 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VGE03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VGE03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VGE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VGE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VGE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VGE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE06 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-VGE06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-VGE06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field ZGDAT CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZGDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZGDAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPDEV, internal->external for field PDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PDEST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-SAKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-SAKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUNE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-DAUNE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-DAUNE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-DAUME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-DAUME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ARBEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ARBEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ARBEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-USE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-USE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANFKO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ANFKO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ANFKO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QRASTEREH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-QRASTEREH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-QRASTEREH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ISTRU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ISTRU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ISTRU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field ISTNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ISTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ISTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field IUPOZ CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-IUPOZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-IUPOZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BMEIH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-BMEIH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-BMEIH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QRASTZEHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-QRASTZEHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-QRASTZEHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZ01 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PRZ01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PRZ01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PLNME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-PLNME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-PLNME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WC_ZEIWN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-WC_ZEIWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-WC_ZEIWN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WC_ZEIWM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-WC_ZEIWM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-WC_ZEIWM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIMU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEIMU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEIMU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIMB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEIMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEIMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEILM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEILM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEILM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEILP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEILP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEILP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEIWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEIWN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEIWM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEIWM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEITN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEITN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEITN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEITM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OPR_BO-ZEITM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OPR_BO-ZEITM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_RTGV_OPR_BO_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
VERSN TYPE STRING,
PLNFL TYPE STRING,
PLNKN TYPE STRING,
DATUV TYPE STRING,
DATUB TYPE STRING,
VERSN_SOURCE TYPE STRING,
VERSN_SOURCE_PLNKN TYPE STRING,
VERSN_TRACK_GUID TYPE STRING,
SET_VERSN_TRACK_GUID TYPE STRING,
FAV_GUID TYPE STRING,
FAV_VERSN TYPE STRING,
FAV_GUID_OLD TYPE STRING,
FAV_VERSN_OLD TYPE STRING,
PLNTY_REFT TYPE STRING,
PLNNR_REFT TYPE STRING,
PLNAL_REFT TYPE STRING,
VERSN_REFT TYPE STRING,
PLNFL_REFT TYPE STRING,
PLNKN_REFT TYPE STRING,
PLNTY_REFT_OLD TYPE STRING,
PLNNR_REFT_OLD TYPE STRING,
PLNAL_REFT_OLD TYPE STRING,
VERSN_REFT_OLD TYPE STRING,
PLNFL_REFT_OLD TYPE STRING,
PLNKN_REFT_OLD TYPE STRING,
AENNR TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
VORNR TYPE STRING,
STEUS TYPE STRING,
ARBID TYPE STRING,
OBJTY TYPE STRING,
WERKS TYPE STRING,
KTSCH TYPE STRING,
LTXA1 TYPE STRING,
MEINH TYPE STRING,
UMREN TYPE STRING,
UMREZ TYPE STRING,
BMSCH TYPE STRING,
ZMERH TYPE STRING,
ZEIER TYPE STRING,
LAR01 TYPE STRING,
VGE01 TYPE STRING,
VGW01 TYPE STRING,
LAR02 TYPE STRING,
VGE02 TYPE STRING,
VGW02 TYPE STRING,
LAR03 TYPE STRING,
VGE03 TYPE STRING,
VGW03 TYPE STRING,
LAR04 TYPE STRING,
VGE04 TYPE STRING,
VGW04 TYPE STRING,
LAR05 TYPE STRING,
VGE05 TYPE STRING,
VGW05 TYPE STRING,
LAR06 TYPE STRING,
VGE06 TYPE STRING,
VGW06 TYPE STRING,
ZERMA TYPE STRING,
ZGDAT TYPE STRING,
ZCODE TYPE STRING,
ZULNR TYPE STRING,
RSANZ TYPE STRING,
PDEST TYPE STRING,
LOANZ TYPE STRING,
LOART TYPE STRING,
ANZMA TYPE STRING,
RFGRP TYPE STRING,
RFSCH TYPE STRING,
RASCH TYPE STRING,
AUFAK TYPE STRING,
LOGRP TYPE STRING,
SORTL TYPE STRING,
LIFNR TYPE STRING,
PLIFZ TYPE STRING,
PREIS TYPE STRING,
PEINH TYPE STRING,
SAKTO TYPE STRING,
WAERS TYPE STRING,
INFNR TYPE STRING,
ESOKZ TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
KZLGF TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
MATKL TYPE STRING,
DAUNO TYPE STRING,
DAUNE TYPE STRING,
DAUMI TYPE STRING,
DAUME TYPE STRING,
DDEHN TYPE STRING,
EINSA TYPE STRING,
EINSE TYPE STRING,
ARBEI TYPE STRING,
ARBEH TYPE STRING,
ANZZL TYPE STRING,
PRZNT TYPE STRING,
VERTL TYPE STRING,
MLSTN TYPE STRING,
PPRIO TYPE STRING,
BUKRS TYPE STRING,
SLWID TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USE04 TYPE STRING,
USR05 TYPE STRING,
USE05 TYPE STRING,
USR06 TYPE STRING,
USE06 TYPE STRING,
USR07 TYPE STRING,
USE07 TYPE STRING,
USR08 TYPE STRING,
USR09 TYPE STRING,
USR10 TYPE STRING,
USR11 TYPE STRING,
ANFKO TYPE STRING,
ANFKOKRS TYPE STRING,
KAPAR TYPE STRING,
INDET TYPE STRING,
LARNT TYPE STRING,
QRASTERMNG TYPE STRING,
QRASTEREH TYPE STRING,
ANLZU TYPE STRING,
ISTRU TYPE STRING,
ISTTY TYPE STRING,
ISTNR TYPE STRING,
ISTKN TYPE STRING,
ISTPO TYPE STRING,
IUPOZ TYPE STRING,
EBORT TYPE STRING,
KALID TYPE STRING,
FRSP TYPE STRING,
VERTN TYPE STRING,
ZGR01 TYPE STRING,
ZGR02 TYPE STRING,
ZGR03 TYPE STRING,
ZGR04 TYPE STRING,
ZGR05 TYPE STRING,
ZGR06 TYPE STRING,
RUZUS TYPE STRING,
BMEIH TYPE STRING,
CKSELKZ TYPE STRING,
KALKZ TYPE STRING,
NPRIO TYPE STRING,
PVZKN TYPE STRING,
KNOBJ TYPE STRING,
ERFSICHT TYPE STRING,
QLOTYPE TYPE STRING,
QLOBJEKTID TYPE STRING,
QLKAPAR TYPE STRING,
QKZPRZEIT TYPE STRING,
QKZZTMG1 TYPE STRING,
QKZPRMENG TYPE STRING,
QKZPRFREI TYPE STRING,
QRASTZEHT TYPE STRING,
QRASTZFAK TYPE STRING,
QRASTMENG TYPE STRING,
QPPKTABS TYPE STRING,
KRIT1 TYPE STRING,
CLASSID TYPE STRING,
CAPOC TYPE STRING,
FLG_CAPTXT TYPE STRING,
QKZTLSBEST TYPE STRING,
AUFKT TYPE STRING,
DAFKT TYPE STRING,
AAUFG TYPE STRING,
FRDLB TYPE STRING,
QPART TYPE STRING,
PRZ01 TYPE STRING,
TAKT TYPE STRING,
ARBPL TYPE STRING,
CLASSNAME TYPE STRING,
CLASS_DES TYPE STRING,
CLASSCAT TYPE STRING,
KOSTL TYPE STRING,
KOKRS TYPE STRING,
INDTX TYPE STRING,
KALTX TYPE STRING,
HERKUNFT TYPE STRING,
QKZPRINI TYPE STRING,
IDENT TYPE STRING,
PLNME TYPE STRING,
WC_ZWNOR TYPE STRING,
WC_ZEIWN TYPE STRING,
WC_ZWMIN TYPE STRING,
WC_ZEIWM TYPE STRING,
LONG_TEXT_EXIST TYPE STRING,
DUMMY_PLPO_INCL_EEW_PS TYPE STRING,
UEMUS TYPE STRING,
UEKAN TYPE STRING,
FLIES TYPE STRING,
ZEIMU TYPE STRING,
ZMINU TYPE STRING,
MINWE TYPE STRING,
SPMUS TYPE STRING,
SPLIM TYPE STRING,
ZEIMB TYPE STRING,
ZMINB TYPE STRING,
ZEILM TYPE STRING,
ZLMAX TYPE STRING,
ZEILP TYPE STRING,
ZLPRO TYPE STRING,
ZEIWN TYPE STRING,
ZWNOR TYPE STRING,
ZEIWM TYPE STRING,
ZWMIN TYPE STRING,
ZEITN TYPE STRING,
ZTNOR TYPE STRING,
ZEITM TYPE STRING,
ZTMIN TYPE STRING,
ABLIPKZ TYPE STRING,
RSTRA TYPE STRING,
OAN_ID_SETUP TYPE STRING,
OAN_VERSION_SETUP TYPE STRING,
OAN_ID_PRODUCE TYPE STRING,
OAN_VERSION_PRODUCE TYPE STRING,
OAN_ID_TEARDOWN TYPE STRING,
OAN_VERSION_TEARDOWN TYPE STRING,
HAS_BUYOFF TYPE STRING,
HAS_LCOMP TYPE STRING,
HAS_QUALIF TYPE STRING,
HAS_WORKINSTR TYPE STRING,
HAS_PREDECESSORS TYPE STRING,
HAS_SUCCESSORS TYPE STRING,
NOT_CHANGEABLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_RTGV_OPR_BO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNTY sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNNR sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNAL sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERSN sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNFL sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNKN sy-vline
WA_MPES_RTGV_OPR_BO_STR-DATUV sy-vline
WA_MPES_RTGV_OPR_BO_STR-DATUB sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERSN_SOURCE sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERSN_SOURCE_PLNKN sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERSN_TRACK_GUID sy-vline
WA_MPES_RTGV_OPR_BO_STR-SET_VERSN_TRACK_GUID sy-vline
WA_MPES_RTGV_OPR_BO_STR-FAV_GUID sy-vline
WA_MPES_RTGV_OPR_BO_STR-FAV_VERSN sy-vline
WA_MPES_RTGV_OPR_BO_STR-FAV_GUID_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-FAV_VERSN_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNTY_REFT sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNNR_REFT sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNAL_REFT sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERSN_REFT sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNFL_REFT sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNKN_REFT sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNTY_REFT_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNNR_REFT_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNAL_REFT_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERSN_REFT_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNFL_REFT_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNKN_REFT_OLD sy-vline
WA_MPES_RTGV_OPR_BO_STR-AENNR sy-vline
WA_MPES_RTGV_OPR_BO_STR-ANDAT sy-vline
WA_MPES_RTGV_OPR_BO_STR-ANNAM sy-vline
WA_MPES_RTGV_OPR_BO_STR-AEDAT sy-vline
WA_MPES_RTGV_OPR_BO_STR-AENAM sy-vline
WA_MPES_RTGV_OPR_BO_STR-VORNR sy-vline
WA_MPES_RTGV_OPR_BO_STR-STEUS sy-vline
WA_MPES_RTGV_OPR_BO_STR-ARBID sy-vline
WA_MPES_RTGV_OPR_BO_STR-OBJTY sy-vline
WA_MPES_RTGV_OPR_BO_STR-WERKS sy-vline
WA_MPES_RTGV_OPR_BO_STR-KTSCH sy-vline
WA_MPES_RTGV_OPR_BO_STR-LTXA1 sy-vline
WA_MPES_RTGV_OPR_BO_STR-MEINH sy-vline
WA_MPES_RTGV_OPR_BO_STR-UMREN sy-vline
WA_MPES_RTGV_OPR_BO_STR-UMREZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-BMSCH sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZMERH sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEIER sy-vline
WA_MPES_RTGV_OPR_BO_STR-LAR01 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGE01 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGW01 sy-vline
WA_MPES_RTGV_OPR_BO_STR-LAR02 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGE02 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGW02 sy-vline
WA_MPES_RTGV_OPR_BO_STR-LAR03 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGE03 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGW03 sy-vline
WA_MPES_RTGV_OPR_BO_STR-LAR04 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGE04 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGW04 sy-vline
WA_MPES_RTGV_OPR_BO_STR-LAR05 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGE05 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGW05 sy-vline
WA_MPES_RTGV_OPR_BO_STR-LAR06 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGE06 sy-vline
WA_MPES_RTGV_OPR_BO_STR-VGW06 sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZERMA sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZGDAT sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZCODE sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZULNR sy-vline
WA_MPES_RTGV_OPR_BO_STR-RSANZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-PDEST sy-vline
WA_MPES_RTGV_OPR_BO_STR-LOANZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-LOART sy-vline
WA_MPES_RTGV_OPR_BO_STR-ANZMA sy-vline
WA_MPES_RTGV_OPR_BO_STR-RFGRP sy-vline
WA_MPES_RTGV_OPR_BO_STR-RFSCH sy-vline
WA_MPES_RTGV_OPR_BO_STR-RASCH sy-vline
WA_MPES_RTGV_OPR_BO_STR-AUFAK sy-vline
WA_MPES_RTGV_OPR_BO_STR-LOGRP sy-vline
WA_MPES_RTGV_OPR_BO_STR-SORTL sy-vline
WA_MPES_RTGV_OPR_BO_STR-LIFNR sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLIFZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-PREIS sy-vline
WA_MPES_RTGV_OPR_BO_STR-PEINH sy-vline
WA_MPES_RTGV_OPR_BO_STR-SAKTO sy-vline
WA_MPES_RTGV_OPR_BO_STR-WAERS sy-vline
WA_MPES_RTGV_OPR_BO_STR-INFNR sy-vline
WA_MPES_RTGV_OPR_BO_STR-ESOKZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-EKORG sy-vline
WA_MPES_RTGV_OPR_BO_STR-EKGRP sy-vline
WA_MPES_RTGV_OPR_BO_STR-KZLGF sy-vline
WA_MPES_RTGV_OPR_BO_STR-EBELN sy-vline
WA_MPES_RTGV_OPR_BO_STR-EBELP sy-vline
WA_MPES_RTGV_OPR_BO_STR-MATKL sy-vline
WA_MPES_RTGV_OPR_BO_STR-DAUNO sy-vline
WA_MPES_RTGV_OPR_BO_STR-DAUNE sy-vline
WA_MPES_RTGV_OPR_BO_STR-DAUMI sy-vline
WA_MPES_RTGV_OPR_BO_STR-DAUME sy-vline
WA_MPES_RTGV_OPR_BO_STR-DDEHN sy-vline
WA_MPES_RTGV_OPR_BO_STR-EINSA sy-vline
WA_MPES_RTGV_OPR_BO_STR-EINSE sy-vline
WA_MPES_RTGV_OPR_BO_STR-ARBEI sy-vline
WA_MPES_RTGV_OPR_BO_STR-ARBEH sy-vline
WA_MPES_RTGV_OPR_BO_STR-ANZZL sy-vline
WA_MPES_RTGV_OPR_BO_STR-PRZNT sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERTL sy-vline
WA_MPES_RTGV_OPR_BO_STR-MLSTN sy-vline
WA_MPES_RTGV_OPR_BO_STR-PPRIO sy-vline
WA_MPES_RTGV_OPR_BO_STR-BUKRS sy-vline
WA_MPES_RTGV_OPR_BO_STR-SLWID sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR00 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR01 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR02 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR03 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR04 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USE04 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR05 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USE05 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR06 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USE06 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR07 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USE07 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR08 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR09 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR10 sy-vline
WA_MPES_RTGV_OPR_BO_STR-USR11 sy-vline
WA_MPES_RTGV_OPR_BO_STR-ANFKO sy-vline
WA_MPES_RTGV_OPR_BO_STR-ANFKOKRS sy-vline
WA_MPES_RTGV_OPR_BO_STR-KAPAR sy-vline
WA_MPES_RTGV_OPR_BO_STR-INDET sy-vline
WA_MPES_RTGV_OPR_BO_STR-LARNT sy-vline
WA_MPES_RTGV_OPR_BO_STR-QRASTERMNG sy-vline
WA_MPES_RTGV_OPR_BO_STR-QRASTEREH sy-vline
WA_MPES_RTGV_OPR_BO_STR-ANLZU sy-vline
WA_MPES_RTGV_OPR_BO_STR-ISTRU sy-vline
WA_MPES_RTGV_OPR_BO_STR-ISTTY sy-vline
WA_MPES_RTGV_OPR_BO_STR-ISTNR sy-vline
WA_MPES_RTGV_OPR_BO_STR-ISTKN sy-vline
WA_MPES_RTGV_OPR_BO_STR-ISTPO sy-vline
WA_MPES_RTGV_OPR_BO_STR-IUPOZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-EBORT sy-vline
WA_MPES_RTGV_OPR_BO_STR-KALID sy-vline
WA_MPES_RTGV_OPR_BO_STR-FRSP sy-vline
WA_MPES_RTGV_OPR_BO_STR-VERTN sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZGR01 sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZGR02 sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZGR03 sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZGR04 sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZGR05 sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZGR06 sy-vline
WA_MPES_RTGV_OPR_BO_STR-RUZUS sy-vline
WA_MPES_RTGV_OPR_BO_STR-BMEIH sy-vline
WA_MPES_RTGV_OPR_BO_STR-CKSELKZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-KALKZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-NPRIO sy-vline
WA_MPES_RTGV_OPR_BO_STR-PVZKN sy-vline
WA_MPES_RTGV_OPR_BO_STR-KNOBJ sy-vline
WA_MPES_RTGV_OPR_BO_STR-ERFSICHT sy-vline
WA_MPES_RTGV_OPR_BO_STR-QLOTYPE sy-vline
WA_MPES_RTGV_OPR_BO_STR-QLOBJEKTID sy-vline
WA_MPES_RTGV_OPR_BO_STR-QLKAPAR sy-vline
WA_MPES_RTGV_OPR_BO_STR-QKZPRZEIT sy-vline
WA_MPES_RTGV_OPR_BO_STR-QKZZTMG1 sy-vline
WA_MPES_RTGV_OPR_BO_STR-QKZPRMENG sy-vline
WA_MPES_RTGV_OPR_BO_STR-QKZPRFREI sy-vline
WA_MPES_RTGV_OPR_BO_STR-QRASTZEHT sy-vline
WA_MPES_RTGV_OPR_BO_STR-QRASTZFAK sy-vline
WA_MPES_RTGV_OPR_BO_STR-QRASTMENG sy-vline
WA_MPES_RTGV_OPR_BO_STR-QPPKTABS sy-vline
WA_MPES_RTGV_OPR_BO_STR-KRIT1 sy-vline
WA_MPES_RTGV_OPR_BO_STR-CLASSID sy-vline
WA_MPES_RTGV_OPR_BO_STR-CAPOC sy-vline
WA_MPES_RTGV_OPR_BO_STR-FLG_CAPTXT sy-vline
WA_MPES_RTGV_OPR_BO_STR-QKZTLSBEST sy-vline
WA_MPES_RTGV_OPR_BO_STR-AUFKT sy-vline
WA_MPES_RTGV_OPR_BO_STR-DAFKT sy-vline
WA_MPES_RTGV_OPR_BO_STR-AAUFG sy-vline
WA_MPES_RTGV_OPR_BO_STR-FRDLB sy-vline
WA_MPES_RTGV_OPR_BO_STR-QPART sy-vline
WA_MPES_RTGV_OPR_BO_STR-PRZ01 sy-vline
WA_MPES_RTGV_OPR_BO_STR-TAKT sy-vline
WA_MPES_RTGV_OPR_BO_STR-ARBPL sy-vline
WA_MPES_RTGV_OPR_BO_STR-CLASSNAME sy-vline
WA_MPES_RTGV_OPR_BO_STR-CLASS_DES sy-vline
WA_MPES_RTGV_OPR_BO_STR-CLASSCAT sy-vline
WA_MPES_RTGV_OPR_BO_STR-KOSTL sy-vline
WA_MPES_RTGV_OPR_BO_STR-KOKRS sy-vline
WA_MPES_RTGV_OPR_BO_STR-INDTX sy-vline
WA_MPES_RTGV_OPR_BO_STR-KALTX sy-vline
WA_MPES_RTGV_OPR_BO_STR-HERKUNFT sy-vline
WA_MPES_RTGV_OPR_BO_STR-QKZPRINI sy-vline
WA_MPES_RTGV_OPR_BO_STR-IDENT sy-vline
WA_MPES_RTGV_OPR_BO_STR-PLNME sy-vline
WA_MPES_RTGV_OPR_BO_STR-WC_ZWNOR sy-vline
WA_MPES_RTGV_OPR_BO_STR-WC_ZEIWN sy-vline
WA_MPES_RTGV_OPR_BO_STR-WC_ZWMIN sy-vline
WA_MPES_RTGV_OPR_BO_STR-WC_ZEIWM sy-vline
WA_MPES_RTGV_OPR_BO_STR-LONG_TEXT_EXIST sy-vline
WA_MPES_RTGV_OPR_BO_STR-DUMMY_PLPO_INCL_EEW_PS sy-vline
WA_MPES_RTGV_OPR_BO_STR-UEMUS sy-vline
WA_MPES_RTGV_OPR_BO_STR-UEKAN sy-vline
WA_MPES_RTGV_OPR_BO_STR-FLIES sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEIMU sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZMINU sy-vline
WA_MPES_RTGV_OPR_BO_STR-MINWE sy-vline
WA_MPES_RTGV_OPR_BO_STR-SPMUS sy-vline
WA_MPES_RTGV_OPR_BO_STR-SPLIM sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEIMB sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZMINB sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEILM sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZLMAX sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEILP sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZLPRO sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEIWN sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZWNOR sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEIWM sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZWMIN sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEITN sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZTNOR sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZEITM sy-vline
WA_MPES_RTGV_OPR_BO_STR-ZTMIN sy-vline
WA_MPES_RTGV_OPR_BO_STR-ABLIPKZ sy-vline
WA_MPES_RTGV_OPR_BO_STR-RSTRA sy-vline
WA_MPES_RTGV_OPR_BO_STR-OAN_ID_SETUP sy-vline
WA_MPES_RTGV_OPR_BO_STR-OAN_VERSION_SETUP sy-vline
WA_MPES_RTGV_OPR_BO_STR-OAN_ID_PRODUCE sy-vline
WA_MPES_RTGV_OPR_BO_STR-OAN_VERSION_PRODUCE sy-vline
WA_MPES_RTGV_OPR_BO_STR-OAN_ID_TEARDOWN sy-vline
WA_MPES_RTGV_OPR_BO_STR-OAN_VERSION_TEARDOWN sy-vline
WA_MPES_RTGV_OPR_BO_STR-HAS_BUYOFF sy-vline
WA_MPES_RTGV_OPR_BO_STR-HAS_LCOMP sy-vline
WA_MPES_RTGV_OPR_BO_STR-HAS_QUALIF sy-vline
WA_MPES_RTGV_OPR_BO_STR-HAS_WORKINSTR sy-vline
WA_MPES_RTGV_OPR_BO_STR-HAS_PREDECESSORS sy-vline
WA_MPES_RTGV_OPR_BO_STR-HAS_SUCCESSORS sy-vline
WA_MPES_RTGV_OPR_BO_STR-NOT_CHANGEABLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.