ABAP Select data from SAP table MPES_RTGV_OP_GEN_COMP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_RTGV_OP_GEN_COMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_RTGV_OP_GEN_COMP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_RTGV_OP_GEN_COMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_RTGV_OP_GEN_COMP TYPE STANDARD TABLE OF MPES_RTGV_OP_GEN_COMP,
      WA_MPES_RTGV_OP_GEN_COMP TYPE MPES_RTGV_OP_GEN_COMP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_RTGV_OP_GEN_COMP> TYPE MPES_RTGV_OP_GEN_COMP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_RTGV_OP_GEN_COMP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_RTGV_OP_GEN_COMP
  INTO TABLE IT_MPES_RTGV_OP_GEN_COMP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_RTGV_OP_GEN_COMP
*  INTO TABLE @DATA(IT_MPES_RTGV_OP_GEN_COMP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_RTGV_OP_GEN_COMP INDEX 1 INTO DATA(WA_MPES_RTGV_OP_GEN_COMP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_RTGV_OP_GEN_COMP ASSIGNING <MPES_RTGV_OP_GEN_COMP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_RTGV_OP_GEN_COMP>-VORNR = 1.
<MPES_RTGV_OP_GEN_COMP>-LTXA1 = 1.
<MPES_RTGV_OP_GEN_COMP>-ARBPL = 1.
<MPES_RTGV_OP_GEN_COMP>-WERKS = 1.
<MPES_RTGV_OP_GEN_COMP>-STEUS = 1.
ENDLOOP.

LOOP AT IT_MPES_RTGV_OP_GEN_COMP INTO WA_MPES_RTGV_OP_GEN_COMP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_RTGV_OP_GEN_COMP-BMSCH, sy-vline,
WA_MPES_RTGV_OP_GEN_COMP-MEINH, sy-vline,
WA_MPES_RTGV_OP_GEN_COMP-ZMERH, sy-vline,
WA_MPES_RTGV_OP_GEN_COMP-ZEIER, sy-vline,
WA_MPES_RTGV_OP_GEN_COMP-UMREZ, sy-vline,
WA_MPES_RTGV_OP_GEN_COMP-UMREN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_RTGV_OP_GEN_COMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_RTGV_OP_GEN_COMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_RTGV_OP_GEN_COMP INTO WA_MPES_RTGV_OP_GEN_COMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIER CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEILP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEILP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEILP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEILM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEILM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEILM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEIWM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEIWM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEIWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEIWN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEITM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEITM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEITM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEITN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEITN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEITN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WC_ZEIWN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-WC_ZEIWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-WC_ZEIWN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WC_ZEIWM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-WC_ZEIWM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-WC_ZEIWM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIMB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEIMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEIMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIMU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-ZEIMU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-ZEIMU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-USE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-USE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE01 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-VGE01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-VGE01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE02 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-VGE02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-VGE02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE03 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-VGE03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-VGE03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-VGE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-VGE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-VGE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-VGE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE06 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-VGE06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-VGE06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-SAKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-SAKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZ01 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_OP_GEN_COMP-PRZ01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_OP_GEN_COMP-PRZ01.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_RTGV_OP_GEN_COMP_STR,
VORNR TYPE STRING,
LTXA1 TYPE STRING,
ARBPL TYPE STRING,
WERKS TYPE STRING,
STEUS TYPE STRING,
BMSCH TYPE STRING,
MEINH TYPE STRING,
ZMERH TYPE STRING,
ZEIER TYPE STRING,
UMREZ TYPE STRING,
UMREN TYPE STRING,
RSTRA TYPE STRING,
ABLIPKZ TYPE STRING,
ZLPRO TYPE STRING,
ZEILP TYPE STRING,
ZLMAX TYPE STRING,
ZEILM TYPE STRING,
ZWMIN TYPE STRING,
ZEIWM TYPE STRING,
ZWNOR TYPE STRING,
ZEIWN TYPE STRING,
ZTMIN TYPE STRING,
ZEITM TYPE STRING,
ZTNOR TYPE STRING,
ZEITN TYPE STRING,
WC_ZWNOR TYPE STRING,
WC_ZEIWN TYPE STRING,
WC_ZWMIN TYPE STRING,
WC_ZEIWM TYPE STRING,
SPMUS TYPE STRING,
SPLIM TYPE STRING,
ZMINB TYPE STRING,
ZEIMB TYPE STRING,
UEMUS TYPE STRING,
UEKAN TYPE STRING,
FLIES TYPE STRING,
ZMINU TYPE STRING,
ZEIMU TYPE STRING,
MINWE TYPE STRING,
AUFAK TYPE STRING,
LOANZ TYPE STRING,
RSANZ TYPE STRING,
LOGRP TYPE STRING,
LOART TYPE STRING,
ANZMA TYPE STRING,
RASCH TYPE STRING,
RFGRP TYPE STRING,
RFSCH TYPE STRING,
CKSELKZ TYPE STRING,
ERFSICHT TYPE STRING,
SLWID TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USE04 TYPE STRING,
USR05 TYPE STRING,
USE05 TYPE STRING,
USR06 TYPE STRING,
USE06 TYPE STRING,
USR07 TYPE STRING,
USE07 TYPE STRING,
USR08 TYPE STRING,
USR09 TYPE STRING,
USR10 TYPE STRING,
USR11 TYPE STRING,
LAR01 TYPE STRING,
VGE01 TYPE STRING,
VGW01 TYPE STRING,
LAR02 TYPE STRING,
VGE02 TYPE STRING,
VGW02 TYPE STRING,
LAR03 TYPE STRING,
VGE03 TYPE STRING,
VGW03 TYPE STRING,
LAR04 TYPE STRING,
VGE04 TYPE STRING,
VGW04 TYPE STRING,
LAR05 TYPE STRING,
VGE05 TYPE STRING,
VGW05 TYPE STRING,
LAR06 TYPE STRING,
VGE06 TYPE STRING,
VGW06 TYPE STRING,
INFNR TYPE STRING,
EKORG TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
SORTL TYPE STRING,
MATKL TYPE STRING,
EKGRP TYPE STRING,
LIFNR TYPE STRING,
PLIFZ TYPE STRING,
PEINH TYPE STRING,
SAKTO TYPE STRING,
PREIS TYPE STRING,
WAERS TYPE STRING,
QPART TYPE STRING,
TEMPLATE_REFERENCE_OBJECT_DISP TYPE STRING,
PRZ01 TYPE STRING,
DUMMY_PLPO_INCL_EEW_PS TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_RTGV_OP_GEN_COMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VORNR sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LTXA1 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ARBPL sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-WERKS sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-STEUS sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-BMSCH sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-MEINH sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZMERH sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEIER sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-UMREZ sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-UMREN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-RSTRA sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ABLIPKZ sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZLPRO sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEILP sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZLMAX sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEILM sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZWMIN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEIWM sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZWNOR sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEIWN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZTMIN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEITM sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZTNOR sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEITN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-WC_ZWNOR sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-WC_ZEIWN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-WC_ZWMIN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-WC_ZEIWM sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-SPMUS sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-SPLIM sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZMINB sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEIMB sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-UEMUS sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-UEKAN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-FLIES sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZMINU sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ZEIMU sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-MINWE sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-AUFAK sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LOANZ sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-RSANZ sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LOGRP sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LOART sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ANZMA sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-RASCH sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-RFGRP sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-RFSCH sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-CKSELKZ sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-ERFSICHT sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-SLWID sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR00 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR01 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR02 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR03 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR04 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USE04 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR05 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USE05 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR06 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USE06 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR07 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USE07 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR08 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR09 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR10 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-USR11 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LAR01 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGE01 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGW01 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LAR02 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGE02 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGW02 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LAR03 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGE03 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGW03 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LAR04 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGE04 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGW04 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LAR05 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGE05 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGW05 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LAR06 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGE06 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-VGW06 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-INFNR sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-EKORG sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-EBELN sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-EBELP sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-SORTL sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-MATKL sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-EKGRP sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-LIFNR sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-PLIFZ sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-PEINH sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-SAKTO sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-PREIS sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-WAERS sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-QPART sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-TEMPLATE_REFERENCE_OBJECT_DISP sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-PRZ01 sy-vline
WA_MPES_RTGV_OP_GEN_COMP_STR-DUMMY_PLPO_INCL_EEW_PS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.