ABAP Select data from SAP table MPES_RTGV_HDR_BO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_RTGV_HDR_BO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_RTGV_HDR_BO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_RTGV_HDR_BO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_RTGV_HDR_BO TYPE STANDARD TABLE OF MPES_RTGV_HDR_BO,
      WA_MPES_RTGV_HDR_BO TYPE MPES_RTGV_HDR_BO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_RTGV_HDR_BO> TYPE MPES_RTGV_HDR_BO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_RTGV_HDR_BO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_RTGV_HDR_BO
  INTO TABLE IT_MPES_RTGV_HDR_BO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_RTGV_HDR_BO
*  INTO TABLE @DATA(IT_MPES_RTGV_HDR_BO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_RTGV_HDR_BO INDEX 1 INTO DATA(WA_MPES_RTGV_HDR_BO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_RTGV_HDR_BO ASSIGNING <MPES_RTGV_HDR_BO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_RTGV_HDR_BO>-PLNTY = 1.
<MPES_RTGV_HDR_BO>-PLNNR = 1.
<MPES_RTGV_HDR_BO>-PLNAL = 1.
<MPES_RTGV_HDR_BO>-VERSN = 1.
<MPES_RTGV_HDR_BO>-RTGV_MODE = 1.
ENDLOOP.

LOOP AT IT_MPES_RTGV_HDR_BO INTO WA_MPES_RTGV_HDR_BO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_RTGV_HDR_BO-STATUS, sy-vline,
WA_MPES_RTGV_HDR_BO-LAST_VERSN, sy-vline,
WA_MPES_RTGV_HDR_BO-NUM_SUC, sy-vline,
WA_MPES_RTGV_HDR_BO-AUFNR, sy-vline,
WA_MPES_RTGV_HDR_BO-CPX_LVL, sy-vline,
WA_MPES_RTGV_HDR_BO-AENNR_REL_CHECK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_RTGV_HDR_BO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_RTGV_HDR_BO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_RTGV_HDR_BO INTO WA_MPES_RTGV_HDR_BO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR_REL_CHECK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-AENNR_REL_CHECK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-AENNR_REL_CHECK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SOURCE_PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-SOURCE_PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-SOURCE_PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SOURCE_PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-SOURCE_PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-SOURCE_PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SOURCE_VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-SOURCE_VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-SOURCE_VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PLNME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_RTGV_HDR_BO-PLNME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_RTGV_HDR_BO-PLNME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_RTGV_HDR_BO_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
VERSN TYPE STRING,
RTGV_MODE TYPE STRING,
STATUS TYPE STRING,
LAST_VERSN TYPE STRING,
NUM_SUC TYPE STRING,
AUFNR TYPE STRING,
CPX_LVL TYPE STRING,
AENNR_REL_CHECK TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
SOURCE_PLNTY TYPE STRING,
SOURCE_PLNNR TYPE STRING,
SOURCE_PLNAL TYPE STRING,
SOURCE_VERSN TYPE STRING,
DUMMY_PLVK_INCL_EEW_PS TYPE STRING,
DATUV TYPE STRING,
AENNR TYPE STRING,
LOEKZ TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
VERWE TYPE STRING,
WERKS TYPE STRING,
STATU TYPE STRING,
PLNME TYPE STRING,
LOSVN TYPE STRING,
LOSBS TYPE STRING,
VAGRP TYPE STRING,
KTEXT TYPE STRING,
ABDAT TYPE STRING,
ABANZ TYPE STRING,
QKZRASTER TYPE STRING,
ARBID TYPE STRING,
DELKZ TYPE STRING,
FLG_CHK TYPE STRING,
SLWBEZ TYPE STRING,
PPKZTLZU TYPE STRING,
QM_IP_TYPE_ALLOWED TYPE STRING,
VALID_TO TYPE STRING,
KAP_ARBPL TYPE STRING,
SUBTYPE TYPE STRING,
ALTEXT TYPE STRING,
REWORK TYPE STRING,
RELAXED TYPE STRING,
EXECUTION_IN_ME TYPE STRING,
ERP_INTEGRATION TYPE STRING,
REFERENCE_TEMPLATE_TYPE TYPE STRING,
REFERENCE_TEMPLATE_CATEGORY TYPE STRING,
REFERENCE_TEMPLATE_OWNER TYPE STRING,
DUMMY_PLKO_INCL_EEW_PS TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_RTGV_HDR_BO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_RTGV_HDR_BO_STR-PLNTY sy-vline
WA_MPES_RTGV_HDR_BO_STR-PLNNR sy-vline
WA_MPES_RTGV_HDR_BO_STR-PLNAL sy-vline
WA_MPES_RTGV_HDR_BO_STR-VERSN sy-vline
WA_MPES_RTGV_HDR_BO_STR-RTGV_MODE sy-vline
WA_MPES_RTGV_HDR_BO_STR-STATUS sy-vline
WA_MPES_RTGV_HDR_BO_STR-LAST_VERSN sy-vline
WA_MPES_RTGV_HDR_BO_STR-NUM_SUC sy-vline
WA_MPES_RTGV_HDR_BO_STR-AUFNR sy-vline
WA_MPES_RTGV_HDR_BO_STR-CPX_LVL sy-vline
WA_MPES_RTGV_HDR_BO_STR-AENNR_REL_CHECK sy-vline
WA_MPES_RTGV_HDR_BO_STR-CREATED_BY sy-vline
WA_MPES_RTGV_HDR_BO_STR-CREATED_AT sy-vline
WA_MPES_RTGV_HDR_BO_STR-CHANGED_BY sy-vline
WA_MPES_RTGV_HDR_BO_STR-CHANGED_AT sy-vline
WA_MPES_RTGV_HDR_BO_STR-SOURCE_PLNTY sy-vline
WA_MPES_RTGV_HDR_BO_STR-SOURCE_PLNNR sy-vline
WA_MPES_RTGV_HDR_BO_STR-SOURCE_PLNAL sy-vline
WA_MPES_RTGV_HDR_BO_STR-SOURCE_VERSN sy-vline
WA_MPES_RTGV_HDR_BO_STR-DUMMY_PLVK_INCL_EEW_PS sy-vline
WA_MPES_RTGV_HDR_BO_STR-DATUV sy-vline
WA_MPES_RTGV_HDR_BO_STR-AENNR sy-vline
WA_MPES_RTGV_HDR_BO_STR-LOEKZ sy-vline
WA_MPES_RTGV_HDR_BO_STR-ANDAT sy-vline
WA_MPES_RTGV_HDR_BO_STR-ANNAM sy-vline
WA_MPES_RTGV_HDR_BO_STR-AEDAT sy-vline
WA_MPES_RTGV_HDR_BO_STR-AENAM sy-vline
WA_MPES_RTGV_HDR_BO_STR-VERWE sy-vline
WA_MPES_RTGV_HDR_BO_STR-WERKS sy-vline
WA_MPES_RTGV_HDR_BO_STR-STATU sy-vline
WA_MPES_RTGV_HDR_BO_STR-PLNME sy-vline
WA_MPES_RTGV_HDR_BO_STR-LOSVN sy-vline
WA_MPES_RTGV_HDR_BO_STR-LOSBS sy-vline
WA_MPES_RTGV_HDR_BO_STR-VAGRP sy-vline
WA_MPES_RTGV_HDR_BO_STR-KTEXT sy-vline
WA_MPES_RTGV_HDR_BO_STR-ABDAT sy-vline
WA_MPES_RTGV_HDR_BO_STR-ABANZ sy-vline
WA_MPES_RTGV_HDR_BO_STR-QKZRASTER sy-vline
WA_MPES_RTGV_HDR_BO_STR-ARBID sy-vline
WA_MPES_RTGV_HDR_BO_STR-DELKZ sy-vline
WA_MPES_RTGV_HDR_BO_STR-FLG_CHK sy-vline
WA_MPES_RTGV_HDR_BO_STR-SLWBEZ sy-vline
WA_MPES_RTGV_HDR_BO_STR-PPKZTLZU sy-vline
WA_MPES_RTGV_HDR_BO_STR-QM_IP_TYPE_ALLOWED sy-vline
WA_MPES_RTGV_HDR_BO_STR-VALID_TO sy-vline
WA_MPES_RTGV_HDR_BO_STR-KAP_ARBPL sy-vline
WA_MPES_RTGV_HDR_BO_STR-SUBTYPE sy-vline
WA_MPES_RTGV_HDR_BO_STR-ALTEXT sy-vline
WA_MPES_RTGV_HDR_BO_STR-REWORK sy-vline
WA_MPES_RTGV_HDR_BO_STR-RELAXED sy-vline
WA_MPES_RTGV_HDR_BO_STR-EXECUTION_IN_ME sy-vline
WA_MPES_RTGV_HDR_BO_STR-ERP_INTEGRATION sy-vline
WA_MPES_RTGV_HDR_BO_STR-REFERENCE_TEMPLATE_TYPE sy-vline
WA_MPES_RTGV_HDR_BO_STR-REFERENCE_TEMPLATE_CATEGORY sy-vline
WA_MPES_RTGV_HDR_BO_STR-REFERENCE_TEMPLATE_OWNER sy-vline
WA_MPES_RTGV_HDR_BO_STR-DUMMY_PLKO_INCL_EEW_PS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.