ABAP Select data from SAP table MPES_EXEC_RR_INSP_CHAR_INFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_EXEC_RR_INSP_CHAR_INFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_EXEC_RR_INSP_CHAR_INFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_EXEC_RR_INSP_CHAR_INFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_EXEC_RR_INSP_CHAR_INFO TYPE STANDARD TABLE OF MPES_EXEC_RR_INSP_CHAR_INFO,
      WA_MPES_EXEC_RR_INSP_CHAR_INFO TYPE MPES_EXEC_RR_INSP_CHAR_INFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_EXEC_RR_INSP_CHAR_INFO> TYPE MPES_EXEC_RR_INSP_CHAR_INFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_EXEC_RR_INSP_CHAR_INFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_EXEC_RR_INSP_CHAR_INFO
  INTO TABLE IT_MPES_EXEC_RR_INSP_CHAR_INFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_EXEC_RR_INSP_CHAR_INFO
*  INTO TABLE @DATA(IT_MPES_EXEC_RR_INSP_CHAR_INFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_EXEC_RR_INSP_CHAR_INFO INDEX 1 INTO DATA(WA_MPES_EXEC_RR_INSP_CHAR_INFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_EXEC_RR_INSP_CHAR_INFO ASSIGNING <MPES_EXEC_RR_INSP_CHAR_INFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_EXEC_RR_INSP_CHAR_INFO>-UNITOFMEASURETECHNICALNAME = 1.
<MPES_EXEC_RR_INSP_CHAR_INFO>-BATCH = 1.
<MPES_EXEC_RR_INSP_CHAR_INFO>-INSPECTIONLOTQUANTITYUNIT = 1.
<MPES_EXEC_RR_INSP_CHAR_INFO>-INSPRESULTVALUECOUNT = 1.
<MPES_EXEC_RR_INSP_CHAR_INFO>-CHARACTERISTICATTRIBUTECODE = 1.
ENDLOOP.

LOOP AT IT_MPES_EXEC_RR_INSP_CHAR_INFO INTO WA_MPES_EXEC_RR_INSP_CHAR_INFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_EXEC_RR_INSP_CHAR_INFO-CHARACTERISTICATTRIBUTECODEGRP, sy-vline,
WA_MPES_EXEC_RR_INSP_CHAR_INFO-CHARACTERISTICATTRIBUTECODETXT, sy-vline,
WA_MPES_EXEC_RR_INSP_CHAR_INFO-CREATEDBYUSER, sy-vline,
WA_MPES_EXEC_RR_INSP_CHAR_INFO-DEFECTFLAG, sy-vline,
WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPCHARACTERISTICSAMPLESIZE, sy-vline,
WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPCHARACTERISTICSAMPLEUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_EXEC_RR_INSP_CHAR_INFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_EXEC_RR_INSP_CHAR_INFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_EXEC_RR_INSP_CHAR_INFO INTO WA_MPES_EXEC_RR_INSP_CHAR_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONMETHODVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONMETHODVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONMETHODVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field INSPECTIONOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONOPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONSPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONSPECIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INSPECTIONSPECIFICATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONSPECIFICATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONSPECIFICATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATIONVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONSPECIFICATIONVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-INSPECTIONSPECIFICATIONVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MANUFACTURINGORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-MANUFACTURINGORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-MANUFACTURINGORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MATERIALSAMPLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-MATERIALSAMPLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-MATERIALSAMPLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PRODUCTIONRESOURCETOOL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-PRODUCTIONRESOURCETOOL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-PRODUCTIONRESOURCETOOL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-QUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-QUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field D_INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-D_INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-D_INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field D_INSPRSLTFREEDEFINEDTESTEQUIP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-D_INSPRSLTFREEDEFINEDTESTEQUIP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-D_INSPRSLTFREEDEFINEDTESTEQUIP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field D_INSPECTIONRESULTITEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_EXEC_RR_INSP_CHAR_INFO-D_INSPECTIONRESULTITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_EXEC_RR_INSP_CHAR_INFO-D_INSPECTIONRESULTITEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_EXEC_RR_INSP_CHAR_INFO_STR,
UNITOFMEASURETECHNICALNAME TYPE STRING,
BATCH TYPE STRING,
INSPECTIONLOTQUANTITYUNIT TYPE STRING,
INSPRESULTVALUECOUNT TYPE STRING,
CHARACTERISTICATTRIBUTECODE TYPE STRING,
CHARACTERISTICATTRIBUTECODEGRP TYPE STRING,
CHARACTERISTICATTRIBUTECODETXT TYPE STRING,
CREATEDBYUSER TYPE STRING,
DEFECTFLAG TYPE STRING,
INSPCHARACTERISTICSAMPLESIZE TYPE STRING,
INSPCHARACTERISTICSAMPLEUNIT TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
INSPECTIONLOTSTARTTIME TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPECTIONMETHOD TYPE STRING,
INSPECTIONMETHODPLANT TYPE STRING,
INSPECTIONMETHODTEXT TYPE STRING,
INSPECTIONMETHODVERSION TYPE STRING,
INSPECTIONOPERATION TYPE STRING,
INSPECTIONRESULTATTRIBUTE TYPE STRING,
INSPECTIONRESULTATTRIBUTETEXT TYPE STRING,
INSPECTIONRESULTHASMEANVALUE TYPE STRING,
INSPECTIONRESULTMEANVALUE TYPE STRING,
INSPECTIONRESULTORIGINTEXT TYPE STRING,
INSPECTIONRESULTSTATUS TYPE STRING,
INSPECTIONRESULTSTATUSTEXT TYPE STRING,
INSPECTIONRESULTTEXT TYPE STRING,
INSPECTIONSAMPLESIZE TYPE STRING,
INSPECTIONSPECIFICATION TYPE STRING,
INSPECTIONSPECIFICATIONPLANT TYPE STRING,
INSPECTIONSPECIFICATIONTEXT TYPE STRING,
INSPECTIONSPECIFICATIONUNIT TYPE STRING,
INSPECTIONSPECIFICATIONVERSION TYPE STRING,
INSPECTIONSUBSETINTERNALID TYPE STRING,
INSPECTIONVALUATIONRESULT TYPE STRING,
INSPECTIONVALUATIONRESULTTEXT TYPE STRING,
INSPECTOR TYPE STRING,
INSPECTORFULLNAME TYPE STRING,
INSPLOTHASSUBSETS TYPE STRING,
INSPLOTTESTEQUIPINTERNALID TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPRESULTSTANDARDDEVIATION TYPE STRING,
INSPRESULTVALIDVALUESNUMBER TYPE STRING,
INSPRESULTVARIANCE TYPE STRING,
INSPRSLTABOVETOLERANCEFRACTION TYPE STRING,
INSPRSLTABOVETOLERANCEVALSNMBR TYPE STRING,
INSPRSLTBELOWTOLERANCEFRACTION TYPE STRING,
INSPRSLTBELOWTOLERANCEVALSNMBR TYPE STRING,
INSPRSLTNONCONFORMINGVALSNMBR TYPE STRING,
INSPSAMPLEACCEPTANCENUMBER TYPE STRING,
INSPSAMPLEREJECTIONNUMBER TYPE STRING,
INSPSAMPLEVALUATIONRULE TYPE STRING,
INSPSPECADDLDECIMALPLACES TYPE STRING,
INSPSPECCHARCCATEGORY TYPE STRING,
INSPSPECCONTROLINDICATORS TYPE STRING,
INSPSPECDECIMALPLACES TYPE STRING,
INSPSPECHASLOWERLIMIT TYPE STRING,
INSPSPECHASTARGETVALUE TYPE STRING,
INSPSPECHASUPPERLIMIT TYPE STRING,
INSPSPECISLONGTERMINSPECTION TYPE STRING,
INSPSPECISMEASUREDVALUERQD TYPE STRING,
INSPSPECISQUANTITATIVE TYPE STRING,
INSPSPECLOWERLIMIT TYPE STRING,
INSPSPECRECORDINGTYPE TYPE STRING,
INSPSPECRESULTCALCULATION TYPE STRING,
INSPSPECSAMPLEQUANTITYFACTOR TYPE STRING,
INSPSPECSUMMARIZEDDCMLPLACES TYPE STRING,
INSPSPECTARGETVALUE TYPE STRING,
INSPSPECUPPERLIMIT TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
MANUFACTURINGORDER TYPE STRING,
MATERIAL TYPE STRING,
MATERIALNAME TYPE STRING,
MATERIALSAMPLE TYPE STRING,
OPERATIONTEXT TYPE STRING,
PLANT TYPE STRING,
PRODUCTIONRESOURCETOOL TYPE STRING,
PRODUCTIONRESOURCETOOLDESC TYPE STRING,
QUANTITYUNIT TYPE STRING,
INSPECTIONNONCONFORMINGRATIO TYPE STRING,
SELECTEDCODESET TYPE STRING,
SELECTEDCODESETTEXT TYPE STRING,
SHOPFLOORITEMEXTERNALID TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERTEXT TYPE STRING,
SHOPFLOORITEM TYPE STRING,
INSPSPECIMPORTANCECODE TYPE STRING,
INSPSPECIMPORTANCECODETEXT TYPE STRING,
D_INSPSPECRECORDINGTYPE TYPE STRING,
D_INSPECTIONSUBSETINTERNALID TYPE STRING,
D_INSPECTIONLOT TYPE STRING,
D_INSPPLANOPERATIONINTERNALID TYPE STRING,
D_INSPECTIONCHARACTERISTIC TYPE STRING,
D_INSPRESULTITEMINTERNALID TYPE STRING,
D_INSPRESULTVALUEINTERNALID TYPE STRING,
D_INSPSPECDECIMALPLACES TYPE STRING,
D_INSPECTIONRESULTATTRIBUTE TYPE STRING,
D_INSPRESULTATTRIBUTETEXT TYPE STRING,
D_INSPSPECISQUANTITATIVE TYPE STRING,
D_INSPECTIONVALUATIONRESULT TYPE STRING,
D_INSPRSLTFREEDEFINEDTESTEQUIP TYPE STRING,
D_INSPECTIONRESULTITEM TYPE STRING,
D_INSPRESULTATTRIBUTEISVALID TYPE STRING,
D_INSPECTIONRESULTTEXT TYPE STRING,
D_INSPRESULTMEASUREDVALUE TYPE STRING,
D_INSPRESULTORIGINALVALUE TYPE STRING,
D_CHARATTRIBUTECATALOG TYPE STRING,
D_CHARACTERISTICATTRIBUTECODE TYPE STRING,
D_CHARATTRIBUTECODEGRP TYPE STRING,
D_CHARATTRIBUTECODETXT TYPE STRING,
D_INSPRESULTVALIDVALUESNUMBER TYPE STRING,
INSPRESULTISDOCUMENTATIONRQD TYPE STRING,
INSPECTIONRESULTHASLONGTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-UNITOFMEASURETECHNICALNAME sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-BATCH sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONLOTQUANTITYUNIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRESULTVALUECOUNT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-CHARACTERISTICATTRIBUTECODE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-CHARACTERISTICATTRIBUTECODEGRP sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-CHARACTERISTICATTRIBUTECODETXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-CREATEDBYUSER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-DEFECTFLAG sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPCHARACTERISTICSAMPLESIZE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPCHARACTERISTICSAMPLEUNIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONLOTTYPE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONLOTSTARTTIME sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONLOT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONMETHOD sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONMETHODPLANT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONMETHODTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONMETHODVERSION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONOPERATION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTATTRIBUTE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTATTRIBUTETEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTHASMEANVALUE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTMEANVALUE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTORIGINTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTSTATUS sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTSTATUSTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONSAMPLESIZE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONSPECIFICATION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONSPECIFICATIONPLANT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONSPECIFICATIONTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONSPECIFICATIONUNIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONSPECIFICATIONVERSION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONSUBSETINTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONVALUATIONRESULT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONVALUATIONRESULTTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTOR sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTORFULLNAME sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPLOTHASSUBSETS sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPLOTTESTEQUIPINTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRESULTSTANDARDDEVIATION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRESULTVALIDVALUESNUMBER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRESULTVARIANCE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRSLTABOVETOLERANCEFRACTION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRSLTABOVETOLERANCEVALSNMBR sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRSLTBELOWTOLERANCEFRACTION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRSLTBELOWTOLERANCEVALSNMBR sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRSLTNONCONFORMINGVALSNMBR sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSAMPLEACCEPTANCENUMBER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSAMPLEREJECTIONNUMBER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSAMPLEVALUATIONRULE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECADDLDECIMALPLACES sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECCHARCCATEGORY sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECCONTROLINDICATORS sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECDECIMALPLACES sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECHASLOWERLIMIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECHASTARGETVALUE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECHASUPPERLIMIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECISLONGTERMINSPECTION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECISMEASUREDVALUERQD sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECISQUANTITATIVE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECLOWERLIMIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECRECORDINGTYPE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECRESULTCALCULATION sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECSAMPLEQUANTITYFACTOR sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECSUMMARIZEDDCMLPLACES sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECTARGETVALUE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECUPPERLIMIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-LASTCHANGEDBYUSER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-MANUFACTURINGORDER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-MATERIAL sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-MATERIALNAME sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-MATERIALSAMPLE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-OPERATIONTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-PLANT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-PRODUCTIONRESOURCETOOL sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-PRODUCTIONRESOURCETOOLDESC sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-QUANTITYUNIT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONNONCONFORMINGRATIO sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-SELECTEDCODESET sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-SELECTEDCODESETTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-SHOPFLOORITEMEXTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-WORKCENTER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-WORKCENTERTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-SHOPFLOORITEM sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECIMPORTANCECODE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPSPECIMPORTANCECODETEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPSPECRECORDINGTYPE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPECTIONSUBSETINTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPECTIONLOT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPPLANOPERATIONINTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPECTIONCHARACTERISTIC sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRESULTITEMINTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRESULTVALUEINTERNALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPSPECDECIMALPLACES sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPECTIONRESULTATTRIBUTE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRESULTATTRIBUTETEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPSPECISQUANTITATIVE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPECTIONVALUATIONRESULT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRSLTFREEDEFINEDTESTEQUIP sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPECTIONRESULTITEM sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRESULTATTRIBUTEISVALID sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPECTIONRESULTTEXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRESULTMEASUREDVALUE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRESULTORIGINALVALUE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_CHARATTRIBUTECATALOG sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_CHARACTERISTICATTRIBUTECODE sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_CHARATTRIBUTECODEGRP sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_CHARATTRIBUTECODETXT sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-D_INSPRESULTVALIDVALUESNUMBER sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPRESULTISDOCUMENTATIONRQD sy-vline
WA_MPES_EXEC_RR_INSP_CHAR_INFO_STR-INSPECTIONRESULTHASLONGTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.