ABAP Select data from SAP table MPES_COMP_ASSEMBLY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_COMP_ASSEMBLY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_COMP_ASSEMBLY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_COMP_ASSEMBLY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_COMP_ASSEMBLY TYPE STANDARD TABLE OF MPES_COMP_ASSEMBLY,
      WA_MPES_COMP_ASSEMBLY TYPE MPES_COMP_ASSEMBLY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_COMP_ASSEMBLY> TYPE MPES_COMP_ASSEMBLY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_COMP_ASSEMBLY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_COMP_ASSEMBLY
  INTO TABLE IT_MPES_COMP_ASSEMBLY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_COMP_ASSEMBLY
*  INTO TABLE @DATA(IT_MPES_COMP_ASSEMBLY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_COMP_ASSEMBLY INDEX 1 INTO DATA(WA_MPES_COMP_ASSEMBLY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_COMP_ASSEMBLY ASSIGNING <MPES_COMP_ASSEMBLY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_COMP_ASSEMBLY>-AUFNR = 1.
<MPES_COMP_ASSEMBLY>-VORNR = 1.
<MPES_COMP_ASSEMBLY>-ADOC_NUMBER = 1.
<MPES_COMP_ASSEMBLY>-ADOC_ITEM = 1.
<MPES_COMP_ASSEMBLY>-OAN_INSTANCE_ID = 1.
ENDLOOP.

LOOP AT IT_MPES_COMP_ASSEMBLY INTO WA_MPES_COMP_ASSEMBLY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_COMP_ASSEMBLY-OAN_ELEMENT_NUMBER, sy-vline,
WA_MPES_COMP_ASSEMBLY-PARENT_SFI_ID, sy-vline,
WA_MPES_COMP_ASSEMBLY-ASSEMBLY_MAT, sy-vline,
WA_MPES_COMP_ASSEMBLY-ASSEMBLY_PLANT, sy-vline,
WA_MPES_COMP_ASSEMBLY-ORDER_QUANTITY, sy-vline,
WA_MPES_COMP_ASSEMBLY-ORDER_UOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_COMP_ASSEMBLY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_COMP_ASSEMBLY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_COMP_ASSEMBLY INTO WA_MPES_COMP_ASSEMBLY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_COMP_ASSEMBLY-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_COMP_ASSEMBLY-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_COMP_ASSEMBLY-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_COMP_ASSEMBLY-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ASSEMBLY_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_COMP_ASSEMBLY-ASSEMBLY_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_COMP_ASSEMBLY-ASSEMBLY_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ORDER_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_COMP_ASSEMBLY-ORDER_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_COMP_ASSEMBLY-ORDER_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field COMPONENT_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_COMP_ASSEMBLY-COMPONENT_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_COMP_ASSEMBLY-COMPONENT_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_COMP_ASSEMBLY-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_COMP_ASSEMBLY-UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_COMP_ASSEMBLY-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_COMP_ASSEMBLY-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_COMP_ASSEMBLY_STR,
AUFNR TYPE STRING,
VORNR TYPE STRING,
ADOC_NUMBER TYPE STRING,
ADOC_ITEM TYPE STRING,
OAN_INSTANCE_ID TYPE STRING,
OAN_ELEMENT_NUMBER TYPE STRING,
PARENT_SFI_ID TYPE STRING,
ASSEMBLY_MAT TYPE STRING,
ASSEMBLY_PLANT TYPE STRING,
ORDER_QUANTITY TYPE STRING,
ORDER_UOM TYPE STRING,
SFI_ID TYPE STRING,
COMPONENT_MAT TYPE STRING,
COMPONENT_PLANT TYPE STRING,
COMPONENT_SLOC TYPE STRING,
BATCH TYPE STRING,
PL_QUANTITY TYPE STRING,
QUANTITY TYPE STRING,
UOM TYPE STRING,
CRTN_USER TYPE STRING,
CRTN_TIME TYPE STRING,
RSNUM TYPE STRING,
RSPOS TYPE STRING,
RSART TYPE STRING,
BACKFLUSH TYPE STRING,
SPECIAL_STOCK_IND TYPE STRING,
ENMNG TYPE STRING,
MEINS TYPE STRING,
SEQUENCE_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_COMP_ASSEMBLY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_COMP_ASSEMBLY_STR-AUFNR sy-vline
WA_MPES_COMP_ASSEMBLY_STR-VORNR sy-vline
WA_MPES_COMP_ASSEMBLY_STR-ADOC_NUMBER sy-vline
WA_MPES_COMP_ASSEMBLY_STR-ADOC_ITEM sy-vline
WA_MPES_COMP_ASSEMBLY_STR-OAN_INSTANCE_ID sy-vline
WA_MPES_COMP_ASSEMBLY_STR-OAN_ELEMENT_NUMBER sy-vline
WA_MPES_COMP_ASSEMBLY_STR-PARENT_SFI_ID sy-vline
WA_MPES_COMP_ASSEMBLY_STR-ASSEMBLY_MAT sy-vline
WA_MPES_COMP_ASSEMBLY_STR-ASSEMBLY_PLANT sy-vline
WA_MPES_COMP_ASSEMBLY_STR-ORDER_QUANTITY sy-vline
WA_MPES_COMP_ASSEMBLY_STR-ORDER_UOM sy-vline
WA_MPES_COMP_ASSEMBLY_STR-SFI_ID sy-vline
WA_MPES_COMP_ASSEMBLY_STR-COMPONENT_MAT sy-vline
WA_MPES_COMP_ASSEMBLY_STR-COMPONENT_PLANT sy-vline
WA_MPES_COMP_ASSEMBLY_STR-COMPONENT_SLOC sy-vline
WA_MPES_COMP_ASSEMBLY_STR-BATCH sy-vline
WA_MPES_COMP_ASSEMBLY_STR-PL_QUANTITY sy-vline
WA_MPES_COMP_ASSEMBLY_STR-QUANTITY sy-vline
WA_MPES_COMP_ASSEMBLY_STR-UOM sy-vline
WA_MPES_COMP_ASSEMBLY_STR-CRTN_USER sy-vline
WA_MPES_COMP_ASSEMBLY_STR-CRTN_TIME sy-vline
WA_MPES_COMP_ASSEMBLY_STR-RSNUM sy-vline
WA_MPES_COMP_ASSEMBLY_STR-RSPOS sy-vline
WA_MPES_COMP_ASSEMBLY_STR-RSART sy-vline
WA_MPES_COMP_ASSEMBLY_STR-BACKFLUSH sy-vline
WA_MPES_COMP_ASSEMBLY_STR-SPECIAL_STOCK_IND sy-vline
WA_MPES_COMP_ASSEMBLY_STR-ENMNG sy-vline
WA_MPES_COMP_ASSEMBLY_STR-MEINS sy-vline
WA_MPES_COMP_ASSEMBLY_STR-SEQUENCE_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.