ABAP Select data from SAP table MPES_ARCH_BUYOFF_HOLD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_ARCH_BUYOFF_HOLD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_ARCH_BUYOFF_HOLD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_ARCH_BUYOFF_HOLD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_ARCH_BUYOFF_HOLD TYPE STANDARD TABLE OF MPES_ARCH_BUYOFF_HOLD,
      WA_MPES_ARCH_BUYOFF_HOLD TYPE MPES_ARCH_BUYOFF_HOLD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_ARCH_BUYOFF_HOLD> TYPE MPES_ARCH_BUYOFF_HOLD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_ARCH_BUYOFF_HOLD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_ARCH_BUYOFF_HOLD
  INTO TABLE IT_MPES_ARCH_BUYOFF_HOLD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_ARCH_BUYOFF_HOLD
*  INTO TABLE @DATA(IT_MPES_ARCH_BUYOFF_HOLD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_ARCH_BUYOFF_HOLD INDEX 1 INTO DATA(WA_MPES_ARCH_BUYOFF_HOLD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_ARCH_BUYOFF_HOLD ASSIGNING <MPES_ARCH_BUYOFF_HOLD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_ARCH_BUYOFF_HOLD>-BUYOFF_SEL = 1.
<MPES_ARCH_BUYOFF_HOLD>-BUYOFF_ANZ = 1.
<MPES_ARCH_BUYOFF_HOLD>-BUYOFF_AFL = 1.
<MPES_ARCH_BUYOFF_HOLD>-BUYOFF_POS = 1.
<MPES_ARCH_BUYOFF_HOLD>-PROFID_HA = 1.
ENDLOOP.

LOOP AT IT_MPES_ARCH_BUYOFF_HOLD INTO WA_MPES_ARCH_BUYOFF_HOLD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_ARCH_BUYOFF_HOLD-HOLD_SEL, sy-vline,
WA_MPES_ARCH_BUYOFF_HOLD-HOLD_ANZ, sy-vline,
WA_MPES_ARCH_BUYOFF_HOLD-HOLD_AFL, sy-vline,
WA_MPES_ARCH_BUYOFF_HOLD-HOLD_POS, sy-vline,
WA_MPES_ARCH_BUYOFF_HOLD-PROFID_HB, sy-vline,
WA_MPES_ARCH_BUYOFF_HOLD-COMP_SEL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_ARCH_BUYOFF_HOLD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_ARCH_BUYOFF_HOLD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_ARCH_BUYOFF_HOLD INTO WA_MPES_ARCH_BUYOFF_HOLD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_ARCH_BUYOFF_HOLD_STR,
BUYOFF_SEL TYPE STRING,
BUYOFF_ANZ TYPE STRING,
BUYOFF_AFL TYPE STRING,
BUYOFF_POS TYPE STRING,
PROFID_HA TYPE STRING,
HOLD_SEL TYPE STRING,
HOLD_ANZ TYPE STRING,
HOLD_AFL TYPE STRING,
HOLD_POS TYPE STRING,
PROFID_HB TYPE STRING,
COMP_SEL TYPE STRING,
COMP_ANZ TYPE STRING,
COMP_AFL TYPE STRING,
COMP_POS TYPE STRING,
PROFID_HC TYPE STRING,
DEF_SEL TYPE STRING,
DEF_ANZ TYPE STRING,
DEF_AFL TYPE STRING,
DEF_POS TYPE STRING,
PROFID_HD TYPE STRING,
LAB_SEL TYPE STRING,
LAB_ANZ TYPE STRING,
LAB_AFL TYPE STRING,
LAB_POS TYPE STRING,
PROFID_HE TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_ARCH_BUYOFF_HOLD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-BUYOFF_SEL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-BUYOFF_ANZ sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-BUYOFF_AFL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-BUYOFF_POS sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-PROFID_HA sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-HOLD_SEL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-HOLD_ANZ sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-HOLD_AFL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-HOLD_POS sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-PROFID_HB sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-COMP_SEL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-COMP_ANZ sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-COMP_AFL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-COMP_POS sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-PROFID_HC sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-DEF_SEL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-DEF_ANZ sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-DEF_AFL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-DEF_POS sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-PROFID_HD sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-LAB_SEL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-LAB_ANZ sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-LAB_AFL sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-LAB_POS sy-vline
WA_MPES_ARCH_BUYOFF_HOLD_STR-PROFID_HE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.