ABAP Select data from SAP table MPE_CM_UP_DR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPE_CM_UP_DR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPE_CM_UP_DR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPE_CM_UP_DR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPE_CM_UP_DR TYPE STANDARD TABLE OF MPE_CM_UP_DR,
      WA_MPE_CM_UP_DR TYPE MPE_CM_UP_DR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPE_CM_UP_DR> TYPE MPE_CM_UP_DR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPE_CM_UP_DR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPE_CM_UP_DR
  INTO TABLE IT_MPE_CM_UP_DR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPE_CM_UP_DR
*  INTO TABLE @DATA(IT_MPE_CM_UP_DR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPE_CM_UP_DR INDEX 1 INTO DATA(WA_MPE_CM_UP_DR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPE_CM_UP_DR ASSIGNING <MPE_CM_UP_DR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPE_CM_UP_DR>-MANDT = 1.
<MPE_CM_UP_DR>-OBJECTTYPE = 1.
<MPE_CM_UP_DR>-ROOT_OBJECTKEY = 1.
<MPE_CM_UP_DR>-OBJECTKEY = 1.
<MPE_CM_UP_DR>-EFFECTIVITY_TYPE = 1.
ENDLOOP.

LOOP AT IT_MPE_CM_UP_DR INTO WA_MPE_CM_UP_DR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPE_CM_UP_DR-AENNR, sy-vline,
WA_MPE_CM_UP_DR-AEEFZ, sy-vline,
WA_MPE_CM_UP_DR-DATE_LO, sy-vline,
WA_MPE_CM_UP_DR-DATE_HI, sy-vline,
WA_MPE_CM_UP_DR-DATE_OI, sy-vline,
WA_MPE_CM_UP_DR-MATNR_LO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPE_CM_UP_DR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPE_CM_UP_DR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPE_CM_UP_DR INTO WA_MPE_CM_UP_DR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_CM_UP_DR-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_CM_UP_DR-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CCMAT, internal->external for field MATNR_LO CALL FUNCTION 'CONVERSION_EXIT_CCMAT_OUTPUT' EXPORTING input = WA_MPE_CM_UP_DR-MATNR_LO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_CM_UP_DR-MATNR_LO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SERNR_LO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_CM_UP_DR-SERNR_LO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_CM_UP_DR-SERNR_LO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SERNR_HI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_CM_UP_DR-SERNR_HI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_CM_UP_DR-SERNR_HI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STARTUP_LO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_CM_UP_DR-STARTUP_LO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_CM_UP_DR-STARTUP_LO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPE_CM_UP_DR_STR,
MANDT TYPE STRING,
OBJECTTYPE TYPE STRING,
ROOT_OBJECTKEY TYPE STRING,
OBJECTKEY TYPE STRING,
EFFECTIVITY_TYPE TYPE STRING,
AENNR TYPE STRING,
AEEFZ TYPE STRING,
DATE_LO TYPE STRING,
DATE_HI TYPE STRING,
DATE_OI TYPE STRING,
MATNR_LO TYPE STRING,
SERNR_LO TYPE STRING,
SERNR_HI TYPE STRING,
PRODUCT_LO TYPE STRING,
CLASS_LO TYPE STRING,
CLASSTY_LO TYPE STRING,
PLANT_LO TYPE STRING,
STARTUP_LO TYPE STRING,
LOCNO_LO TYPE STRING,
SERNR_OI TYPE STRING,
IS_DELETED TYPE STRING,
CHANGEDAT TYPE STRING,
CREATEDBY TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPE_CM_UP_DR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPE_CM_UP_DR_STR-MANDT sy-vline
WA_MPE_CM_UP_DR_STR-OBJECTTYPE sy-vline
WA_MPE_CM_UP_DR_STR-ROOT_OBJECTKEY sy-vline
WA_MPE_CM_UP_DR_STR-OBJECTKEY sy-vline
WA_MPE_CM_UP_DR_STR-EFFECTIVITY_TYPE sy-vline
WA_MPE_CM_UP_DR_STR-AENNR sy-vline
WA_MPE_CM_UP_DR_STR-AEEFZ sy-vline
WA_MPE_CM_UP_DR_STR-DATE_LO sy-vline
WA_MPE_CM_UP_DR_STR-DATE_HI sy-vline
WA_MPE_CM_UP_DR_STR-DATE_OI sy-vline
WA_MPE_CM_UP_DR_STR-MATNR_LO sy-vline
WA_MPE_CM_UP_DR_STR-SERNR_LO sy-vline
WA_MPE_CM_UP_DR_STR-SERNR_HI sy-vline
WA_MPE_CM_UP_DR_STR-PRODUCT_LO sy-vline
WA_MPE_CM_UP_DR_STR-CLASS_LO sy-vline
WA_MPE_CM_UP_DR_STR-CLASSTY_LO sy-vline
WA_MPE_CM_UP_DR_STR-PLANT_LO sy-vline
WA_MPE_CM_UP_DR_STR-STARTUP_LO sy-vline
WA_MPE_CM_UP_DR_STR-LOCNO_LO sy-vline
WA_MPE_CM_UP_DR_STR-SERNR_OI sy-vline
WA_MPE_CM_UP_DR_STR-IS_DELETED sy-vline
WA_MPE_CM_UP_DR_STR-CHANGEDAT sy-vline
WA_MPE_CM_UP_DR_STR-CREATEDBY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.