ABAP Select data from SAP table MIG_BUS_EI_BUPA_SSF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MIG_BUS_EI_BUPA_SSF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MIG_BUS_EI_BUPA_SSF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MIG_BUS_EI_BUPA_SSF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MIG_BUS_EI_BUPA_SSF TYPE STANDARD TABLE OF MIG_BUS_EI_BUPA_SSF,
      WA_MIG_BUS_EI_BUPA_SSF TYPE MIG_BUS_EI_BUPA_SSF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MIG_BUS_EI_BUPA_SSF> TYPE MIG_BUS_EI_BUPA_SSF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MIG_BUS_EI_BUPA_SSF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MIG_BUS_EI_BUPA_SSF
  INTO TABLE IT_MIG_BUS_EI_BUPA_SSF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MIG_BUS_EI_BUPA_SSF
*  INTO TABLE @DATA(IT_MIG_BUS_EI_BUPA_SSF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MIG_BUS_EI_BUPA_SSF INDEX 1 INTO DATA(WA_MIG_BUS_EI_BUPA_SSF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MIG_BUS_EI_BUPA_SSF ASSIGNING <MIG_BUS_EI_BUPA_SSF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MIG_BUS_EI_BUPA_SSF>-STD_NODAT = 1.
<MIG_BUS_EI_BUPA_SSF>-DUMMYDAT = 1.
<MIG_BUS_EI_BUPA_SSF>-STD_RECIPDAT = 1.
<MIG_BUS_EI_BUPA_SSF>-HOME_FLAGDAT = 1.
<MIG_BUS_EI_BUPA_SSF>-CONSNUMBERDAT = 1.
ENDLOOP.

LOOP AT IT_MIG_BUS_EI_BUPA_SSF INTO WA_MIG_BUS_EI_BUPA_SSF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MIG_BUS_EI_BUPA_SSF-RFCDESTDAT, sy-vline,
WA_MIG_BUS_EI_BUPA_SSF-SSFIDSHORTDAT, sy-vline,
WA_MIG_BUS_EI_BUPA_SSF-SSF_NSDAT, sy-vline,
WA_MIG_BUS_EI_BUPA_SSF-SSF_PROFDAT, sy-vline,
WA_MIG_BUS_EI_BUPA_SSF-SSFIDPART1DAT, sy-vline,
WA_MIG_BUS_EI_BUPA_SSF-SSFIDPART2DAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MIG_BUS_EI_BUPA_SSF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MIG_BUS_EI_BUPA_SSF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MIG_BUS_EI_BUPA_SSF INTO WA_MIG_BUS_EI_BUPA_SSF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MIG_BUS_EI_BUPA_SSF_STR,
STD_NODAT TYPE STRING,
DUMMYDAT TYPE STRING,
STD_RECIPDAT TYPE STRING,
HOME_FLAGDAT TYPE STRING,
CONSNUMBERDAT TYPE STRING,
RFCDESTDAT TYPE STRING,
SSFIDSHORTDAT TYPE STRING,
SSF_NSDAT TYPE STRING,
SSF_PROFDAT TYPE STRING,
SSFIDPART1DAT TYPE STRING,
SSFIDPART2DAT TYPE STRING,
SSFIDPART3DAT TYPE STRING,
SSFIDPART4DAT TYPE STRING,
SSFIDPART5DAT TYPE STRING,
SSFIDPART6DAT TYPE STRING,
SSFIDPART7DAT TYPE STRING,
SSFIDPART8DAT TYPE STRING,
SSFIDPART9DAT TYPE STRING,
ERRORFLAGDAT TYPE STRING,
FLG_NOUSEDAT TYPE STRING,
VALID_FROMDAT TYPE STRING,
VALID_TODAT TYPE STRING,
REMARKS TYPE STRING,
CURRENTLY_VALID TYPE STRING,
COMM_USAGES TYPE STRING,END OF T_EKKO_STR. DATA: WA_MIG_BUS_EI_BUPA_SSF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-STD_NODAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-DUMMYDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-STD_RECIPDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-HOME_FLAGDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-CONSNUMBERDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-RFCDESTDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDSHORTDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSF_NSDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSF_PROFDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART1DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART2DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART3DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART4DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART5DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART6DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART7DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART8DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-SSFIDPART9DAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-ERRORFLAGDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-FLG_NOUSEDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-VALID_FROMDAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-VALID_TODAT sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-REMARKS sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-CURRENTLY_VALID sy-vline
WA_MIG_BUS_EI_BUPA_SSF_STR-COMM_USAGES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.