ABAP Select data from SAP table MEWICONDITION_TY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MEWICONDITION_TY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MEWICONDITION_TY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MEWICONDITION_TY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MEWICONDITION_TY TYPE STANDARD TABLE OF MEWICONDITION_TY,
      WA_MEWICONDITION_TY TYPE MEWICONDITION_TY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MEWICONDITION_TY> TYPE MEWICONDITION_TY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MEWICONDITION_TY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MEWICONDITION_TY
  INTO TABLE IT_MEWICONDITION_TY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MEWICONDITION_TY
*  INTO TABLE @DATA(IT_MEWICONDITION_TY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MEWICONDITION_TY INDEX 1 INTO DATA(WA_MEWICONDITION_TY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MEWICONDITION_TY ASSIGNING <MEWICONDITION_TY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MEWICONDITION_TY>-INFO_REC = 1.
<MEWICONDITION_TY>-EINE_INDX = 1.
<MEWICONDITION_TY>-SERIAL_ID = 1.
<MEWICONDITION_TY>-COND_COUNT = 1.
<MEWICONDITION_TY>-DELETION_IND = 1.
ENDLOOP.

LOOP AT IT_MEWICONDITION_TY INTO WA_MEWICONDITION_TY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MEWICONDITION_TY-COND_TYPE, sy-vline,
WA_MEWICONDITION_TY-SCALE_TYPE, sy-vline,
WA_MEWICONDITION_TY-SCALE_BASE_TY, sy-vline,
WA_MEWICONDITION_TY-SCALE_UNIT, sy-vline,
WA_MEWICONDITION_TY-SCALE_UNIT_ISO, sy-vline,
WA_MEWICONDITION_TY-SCALE_CURR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MEWICONDITION_TY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MEWICONDITION_TY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MEWICONDITION_TY INTO WA_MEWICONDITION_TY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INFO_REC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MEWICONDITION_TY-INFO_REC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEWICONDITION_TY-INFO_REC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SCALE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MEWICONDITION_TY-SCALE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEWICONDITION_TY-SCALE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field COND_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MEWICONDITION_TY-COND_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEWICONDITION_TY-COND_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MEWICONDITION_TY-BASE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEWICONDITION_TY-BASE_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VENDOR_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MEWICONDITION_TY-VENDOR_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEWICONDITION_TY-VENDOR_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MEWICONDITION_TY_STR,
INFO_REC TYPE STRING,
EINE_INDX TYPE STRING,
SERIAL_ID TYPE STRING,
COND_COUNT TYPE STRING,
DELETION_IND TYPE STRING,
COND_TYPE TYPE STRING,
SCALE_TYPE TYPE STRING,
SCALE_BASE_TY TYPE STRING,
SCALE_UNIT TYPE STRING,
SCALE_UNIT_ISO TYPE STRING,
SCALE_CURR TYPE STRING,
SCALE_CURR_ISO TYPE STRING,
CALCTYPCON TYPE STRING,
COND_VALUE TYPE STRING,
CURRENCY TYPE STRING,
CURRENCY_ISO TYPE STRING,
COND_P_UNT TYPE STRING,
COND_UNIT TYPE STRING,
COND_UNIT_ISO TYPE STRING,
NUMERATOR TYPE STRING,
DENOMINATOR TYPE STRING,
BASE_UOM TYPE STRING,
BASE_UOM_ISO TYPE STRING,
LOWERLIMIT TYPE STRING,
UPPERLIMIT TYPE STRING,
VENDOR_NO TYPE STRING,
CHANGE_ID TYPE STRING,
EXCLUSION_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_MEWICONDITION_TY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MEWICONDITION_TY_STR-INFO_REC sy-vline
WA_MEWICONDITION_TY_STR-EINE_INDX sy-vline
WA_MEWICONDITION_TY_STR-SERIAL_ID sy-vline
WA_MEWICONDITION_TY_STR-COND_COUNT sy-vline
WA_MEWICONDITION_TY_STR-DELETION_IND sy-vline
WA_MEWICONDITION_TY_STR-COND_TYPE sy-vline
WA_MEWICONDITION_TY_STR-SCALE_TYPE sy-vline
WA_MEWICONDITION_TY_STR-SCALE_BASE_TY sy-vline
WA_MEWICONDITION_TY_STR-SCALE_UNIT sy-vline
WA_MEWICONDITION_TY_STR-SCALE_UNIT_ISO sy-vline
WA_MEWICONDITION_TY_STR-SCALE_CURR sy-vline
WA_MEWICONDITION_TY_STR-SCALE_CURR_ISO sy-vline
WA_MEWICONDITION_TY_STR-CALCTYPCON sy-vline
WA_MEWICONDITION_TY_STR-COND_VALUE sy-vline
WA_MEWICONDITION_TY_STR-CURRENCY sy-vline
WA_MEWICONDITION_TY_STR-CURRENCY_ISO sy-vline
WA_MEWICONDITION_TY_STR-COND_P_UNT sy-vline
WA_MEWICONDITION_TY_STR-COND_UNIT sy-vline
WA_MEWICONDITION_TY_STR-COND_UNIT_ISO sy-vline
WA_MEWICONDITION_TY_STR-NUMERATOR sy-vline
WA_MEWICONDITION_TY_STR-DENOMINATOR sy-vline
WA_MEWICONDITION_TY_STR-BASE_UOM sy-vline
WA_MEWICONDITION_TY_STR-BASE_UOM_ISO sy-vline
WA_MEWICONDITION_TY_STR-LOWERLIMIT sy-vline
WA_MEWICONDITION_TY_STR-UPPERLIMIT sy-vline
WA_MEWICONDITION_TY_STR-VENDOR_NO sy-vline
WA_MEWICONDITION_TY_STR-CHANGE_ID sy-vline
WA_MEWICONDITION_TY_STR-EXCLUSION_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.