ABAP Select data from SAP table MEV_S_AD_ITEM_SD_WORK_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MEV_S_AD_ITEM_SD_WORK_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MEV_S_AD_ITEM_SD_WORK_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MEV_S_AD_ITEM_SD_WORK_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MEV_S_AD_ITEM_SD_WORK_DATA TYPE STANDARD TABLE OF MEV_S_AD_ITEM_SD_WORK_DATA,
      WA_MEV_S_AD_ITEM_SD_WORK_DATA TYPE MEV_S_AD_ITEM_SD_WORK_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MEV_S_AD_ITEM_SD_WORK_DATA> TYPE MEV_S_AD_ITEM_SD_WORK_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MEV_S_AD_ITEM_SD_WORK_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MEV_S_AD_ITEM_SD_WORK_DATA
  INTO TABLE IT_MEV_S_AD_ITEM_SD_WORK_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MEV_S_AD_ITEM_SD_WORK_DATA
*  INTO TABLE @DATA(IT_MEV_S_AD_ITEM_SD_WORK_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MEV_S_AD_ITEM_SD_WORK_DATA INDEX 1 INTO DATA(WA_MEV_S_AD_ITEM_SD_WORK_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MEV_S_AD_ITEM_SD_WORK_DATA ASSIGNING <MEV_S_AD_ITEM_SD_WORK_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MEV_S_AD_ITEM_SD_WORK_DATA>-VBELN_POST = 1.
<MEV_S_AD_ITEM_SD_WORK_DATA>-POSNR_POST = 1.
<MEV_S_AD_ITEM_SD_WORK_DATA>-POSNR_POST_2 = 1.
<MEV_S_AD_ITEM_SD_WORK_DATA>-VBELN_RESET = 1.
<MEV_S_AD_ITEM_SD_WORK_DATA>-POSNR_RESET = 1.
ENDLOOP.

LOOP AT IT_MEV_S_AD_ITEM_SD_WORK_DATA INTO WA_MEV_S_AD_ITEM_SD_WORK_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MEV_S_AD_ITEM_SD_WORK_DATA-POSNR_RESET_2, sy-vline,
WA_MEV_S_AD_ITEM_SD_WORK_DATA-VKORG, sy-vline,
WA_MEV_S_AD_ITEM_SD_WORK_DATA-VTWEG, sy-vline,
WA_MEV_S_AD_ITEM_SD_WORK_DATA-SPART, sy-vline,
WA_MEV_S_AD_ITEM_SD_WORK_DATA-VKGRP, sy-vline,
WA_MEV_S_AD_ITEM_SD_WORK_DATA-VKBUR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MEV_S_AD_ITEM_SD_WORK_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MEV_S_AD_ITEM_SD_WORK_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MEV_S_AD_ITEM_SD_WORK_DATA INTO WA_MEV_S_AD_ITEM_SD_WORK_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN_POST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MEV_S_AD_ITEM_SD_WORK_DATA-VBELN_POST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEV_S_AD_ITEM_SD_WORK_DATA-VBELN_POST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN_RESET CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MEV_S_AD_ITEM_SD_WORK_DATA-VBELN_RESET IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEV_S_AD_ITEM_SD_WORK_DATA-VBELN_RESET.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNAG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MEV_S_AD_ITEM_SD_WORK_DATA-KUNAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MEV_S_AD_ITEM_SD_WORK_DATA-KUNAG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MEV_S_AD_ITEM_SD_WORK_DATA_STR,
VBELN_POST TYPE STRING,
POSNR_POST TYPE STRING,
POSNR_POST_2 TYPE STRING,
VBELN_RESET TYPE STRING,
POSNR_RESET TYPE STRING,
POSNR_RESET_2 TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
VKGRP TYPE STRING,
VKBUR TYPE STRING,
KUNAG TYPE STRING,
VBTYP_OBJ TYPE STRING,
NAME1 TYPE STRING,
KNUMV TYPE STRING,
VBTYP_POST TYPE STRING,
VBTYP_RESET TYPE STRING,
FKART_POST TYPE STRING,END OF T_EKKO_STR. DATA: WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VBELN_POST sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-POSNR_POST sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-POSNR_POST_2 sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VBELN_RESET sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-POSNR_RESET sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-POSNR_RESET_2 sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VKORG sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VTWEG sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-SPART sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VKGRP sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VKBUR sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-KUNAG sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VBTYP_OBJ sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-NAME1 sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-KNUMV sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VBTYP_POST sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-VBTYP_RESET sy-vline
WA_MEV_S_AD_ITEM_SD_WORK_DATA_STR-FKART_POST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.