ABAP Select data from SAP table MDG_BS_SUPPL_BP_VENVAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MDG_BS_SUPPL_BP_VENVAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MDG_BS_SUPPL_BP_VENVAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MDG_BS_SUPPL_BP_VENVAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MDG_BS_SUPPL_BP_VENVAL TYPE STANDARD TABLE OF MDG_BS_SUPPL_BP_VENVAL,
      WA_MDG_BS_SUPPL_BP_VENVAL TYPE MDG_BS_SUPPL_BP_VENVAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MDG_BS_SUPPL_BP_VENVAL> TYPE MDG_BS_SUPPL_BP_VENVAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MDG_BS_SUPPL_BP_VENVAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MDG_BS_SUPPL_BP_VENVAL
  INTO TABLE IT_MDG_BS_SUPPL_BP_VENVAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MDG_BS_SUPPL_BP_VENVAL
*  INTO TABLE @DATA(IT_MDG_BS_SUPPL_BP_VENVAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MDG_BS_SUPPL_BP_VENVAL INDEX 1 INTO DATA(WA_MDG_BS_SUPPL_BP_VENVAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MDG_BS_SUPPL_BP_VENVAL ASSIGNING <MDG_BS_SUPPL_BP_VENVAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MDG_BS_SUPPL_BP_VENVAL>-ASSGNM_ID = 1.
<MDG_BS_SUPPL_BP_VENVAL>-BP_HEADER = 1.
<MDG_BS_SUPPL_BP_VENVAL>-CHARID = 1.
<MDG_BS_SUPPL_BP_VENVAL>-CLASSTYPE = 1.
<MDG_BS_SUPPL_BP_VENVAL>-ECOCNTR = 1.
ENDLOOP.

LOOP AT IT_MDG_BS_SUPPL_BP_VENVAL INTO WA_MDG_BS_SUPPL_BP_VENVAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MDG_BS_SUPPL_BP_VENVAL-VALCNT, sy-vline,
WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATAUT, sy-vline,
WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATAW1, sy-vline,
WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATAWE, sy-vline,
WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATCOD, sy-vline,
WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATFLB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MDG_BS_SUPPL_BP_VENVAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MDG_BS_SUPPL_BP_VENVAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MDG_BS_SUPPL_BP_VENVAL INTO WA_MDG_BS_SUPPL_BP_VENVAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BP_HEADER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MDG_BS_SUPPL_BP_VENVAL-BP_HEADER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MDG_BS_SUPPL_BP_VENVAL-BP_HEADER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ATINN, internal->external for field CHARID CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_MDG_BS_SUPPL_BP_VENVAL-CHARID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MDG_BS_SUPPL_BP_VENVAL-CHARID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VEN_ATAW1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATAW1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATAW1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VEN_ATAWE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATAWE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MDG_BS_SUPPL_BP_VENVAL-VEN_ATAWE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MDG_BS_SUPPL_BP_VENVAL_STR,
ASSGNM_ID TYPE STRING,
BP_HEADER TYPE STRING,
CHARID TYPE STRING,
CLASSTYPE TYPE STRING,
ECOCNTR TYPE STRING,
VALCNT TYPE STRING,
VEN_ATAUT TYPE STRING,
VEN_ATAW1 TYPE STRING,
VEN_ATAWE TYPE STRING,
VEN_ATCOD TYPE STRING,
VEN_ATFLB TYPE STRING,
VEN_ATFLV TYPE STRING,
VEN_ATIMB TYPE STRING,
VEN_ATSRT TYPE STRING,
VEN_ATWRT TYPE STRING,
VEN_ATZIS TYPE STRING,
VEN_VADEL TYPE STRING,
VEN_VADVF TYPE STRING,
VEN_VGLAR TYPE STRING,END OF T_EKKO_STR. DATA: WA_MDG_BS_SUPPL_BP_VENVAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-ASSGNM_ID sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-BP_HEADER sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-CHARID sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-CLASSTYPE sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-ECOCNTR sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VALCNT sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATAUT sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATAW1 sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATAWE sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATCOD sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATFLB sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATFLV sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATIMB sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATSRT sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATWRT sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_ATZIS sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_VADEL sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_VADVF sy-vline
WA_MDG_BS_SUPPL_BP_VENVAL_STR-VEN_VGLAR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.