ABAP Select data from SAP table MCEXLOG_04_MAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MCEXLOG_04_MAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MCEXLOG_04_MAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MCEXLOG_04_MAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MCEXLOG_04_MAT TYPE STANDARD TABLE OF MCEXLOG_04_MAT,
      WA_MCEXLOG_04_MAT TYPE MCEXLOG_04_MAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MCEXLOG_04_MAT> TYPE MCEXLOG_04_MAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MCEXLOG_04_MAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MCEXLOG_04_MAT
  INTO TABLE IT_MCEXLOG_04_MAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MCEXLOG_04_MAT
*  INTO TABLE @DATA(IT_MCEXLOG_04_MAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MCEXLOG_04_MAT INDEX 1 INTO DATA(WA_MCEXLOG_04_MAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MCEXLOG_04_MAT ASSIGNING <MCEXLOG_04_MAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MCEXLOG_04_MAT>-TCODE = 1.
<MCEXLOG_04_MAT>-DATUM = 1.
<MCEXLOG_04_MAT>-UZEIT = 1.
<MCEXLOG_04_MAT>-UNAME = 1.
<MCEXLOG_04_MAT>-HOST = 1.
ENDLOOP.

LOOP AT IT_MCEXLOG_04_MAT INTO WA_MCEXLOG_04_MAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MCEXLOG_04_MAT-ROCANCEL, sy-vline,
WA_MCEXLOG_04_MAT-AUFNR, sy-vline,
WA_MCEXLOG_04_MAT-FTRMI, sy-vline,
WA_MCEXLOG_04_MAT-GETRI, sy-vline,
WA_MCEXLOG_04_MAT-GLTRP, sy-vline,
WA_MCEXLOG_04_MAT-LEAD_AUFNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MCEXLOG_04_MAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MCEXLOG_04_MAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MCEXLOG_04_MAT INTO WA_MCEXLOG_04_MAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MCEXLOG_04_MAT-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MCEXLOG_04_MAT-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LEAD_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MCEXLOG_04_MAT-LEAD_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MCEXLOG_04_MAT-LEAD_AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MCEXLOG_04_MAT-MAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MCEXLOG_04_MAT-MAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MCEXLOG_04_MAT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MCEXLOG_04_MAT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MCEXLOG_04_MAT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MCEXLOG_04_MAT-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MCEXLOG_04_MAT_STR,
TCODE TYPE STRING,
DATUM TYPE STRING,
UZEIT TYPE STRING,
UNAME TYPE STRING,
HOST TYPE STRING,
ROCANCEL TYPE STRING,
AUFNR TYPE STRING,
FTRMI TYPE STRING,
GETRI TYPE STRING,
GLTRP TYPE STRING,
LEAD_AUFNR TYPE STRING,
MAUFNR TYPE STRING,
WERKS TYPE STRING,
BUDAT TYPE STRING,
MATNR TYPE STRING,
MEINS TYPE STRING,
POSNR TYPE STRING,
PSMNG TYPE STRING,
PWERK TYPE STRING,
ZEITP TYPE STRING,END OF T_EKKO_STR. DATA: WA_MCEXLOG_04_MAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MCEXLOG_04_MAT_STR-TCODE sy-vline
WA_MCEXLOG_04_MAT_STR-DATUM sy-vline
WA_MCEXLOG_04_MAT_STR-UZEIT sy-vline
WA_MCEXLOG_04_MAT_STR-UNAME sy-vline
WA_MCEXLOG_04_MAT_STR-HOST sy-vline
WA_MCEXLOG_04_MAT_STR-ROCANCEL sy-vline
WA_MCEXLOG_04_MAT_STR-AUFNR sy-vline
WA_MCEXLOG_04_MAT_STR-FTRMI sy-vline
WA_MCEXLOG_04_MAT_STR-GETRI sy-vline
WA_MCEXLOG_04_MAT_STR-GLTRP sy-vline
WA_MCEXLOG_04_MAT_STR-LEAD_AUFNR sy-vline
WA_MCEXLOG_04_MAT_STR-MAUFNR sy-vline
WA_MCEXLOG_04_MAT_STR-WERKS sy-vline
WA_MCEXLOG_04_MAT_STR-BUDAT sy-vline
WA_MCEXLOG_04_MAT_STR-MATNR sy-vline
WA_MCEXLOG_04_MAT_STR-MEINS sy-vline
WA_MCEXLOG_04_MAT_STR-POSNR sy-vline
WA_MCEXLOG_04_MAT_STR-PSMNG sy-vline
WA_MCEXLOG_04_MAT_STR-PWERK sy-vline
WA_MCEXLOG_04_MAT_STR-ZEITP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.