ABAP Select data from SAP table MCDISPO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MCDISPO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MCDISPO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MCDISPO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MCDISPO TYPE STANDARD TABLE OF MCDISPO,
      WA_MCDISPO TYPE MCDISPO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MCDISPO> TYPE MCDISPO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MCDISPO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MCDISPO
  INTO TABLE IT_MCDISPO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MCDISPO
*  INTO TABLE @DATA(IT_MCDISPO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MCDISPO INDEX 1 INTO DATA(WA_MCDISPO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MCDISPO ASSIGNING <MCDISPO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MCDISPO>-MATNR = 1.
<MCDISPO>-WERKS = 1.
<MCDISPO>-DISPO = 1.
<MCDISPO>-DISMM = 1.
<MCDISPO>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_MCDISPO INTO WA_MCDISPO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MCDISPO-PLAAB, sy-vline,
WA_MCDISPO-PLANR, sy-vline,
WA_MCDISPO-SORT0, sy-vline,
WA_MCDISPO-DELKZ, sy-vline,
WA_MCDISPO-DAT00, sy-vline,
WA_MCDISPO-PERKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MCDISPO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MCDISPO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MCDISPO INTO WA_MCDISPO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MCDISPO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MCDISPO-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MCDISPO-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MCDISPO-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MCDISPO_STR,
MATNR TYPE STRING,
WERKS TYPE STRING,
DISPO TYPE STRING,
DISMM TYPE STRING,
BUKRS TYPE STRING,
PLAAB TYPE STRING,
PLANR TYPE STRING,
SORT0 TYPE STRING,
DELKZ TYPE STRING,
DAT00 TYPE STRING,
PERKZ TYPE STRING,
PRPER TYPE STRING,
ANZFD TYPE STRING,
EXTSU TYPE STRING,
MNG01 TYPE STRING,
MNG02 TYPE STRING,
MNG03 TYPE STRING,
MNG04 TYPE STRING,
MNG05 TYPE STRING,
MNG06 TYPE STRING,
MNG07 TYPE STRING,
ISTRW TYPE STRING,
SLRWX TYPE STRING,
MIRWX TYPE STRING,
MARWX TYPE STRING,
SLBES TYPE STRING,
MDBES TYPE STRING,
MXBES TYPE STRING,
TGBED TYPE STRING,
TGPRO TYPE STRING,
BERW1 TYPE STRING,
BERW2 TYPE STRING,
SSTOCK TYPE STRING,
ANZBV TYPE STRING,
AZZUG TYPE STRING,
ALINE TYPE STRING,
ELINE TYPE STRING,
FBYTE TYPE STRING,
AKZ01 TYPE STRING,
AKZ02 TYPE STRING,
AKZ03 TYPE STRING,
AKZ04 TYPE STRING,
USEX1 TYPE STRING,
USEX2 TYPE STRING,
USEX3 TYPE STRING,
DETAIL_ICON TYPE STRING,
WAERS TYPE STRING,
MEINS TYPE STRING,
EISBE TYPE STRING,
BESZUG TYPE STRING,
ANZUG TYPE STRING,
MZUGA TYPE STRING,
MABGA TYPE STRING,
MBEST TYPE STRING,
MATP TYPE STRING,
GSBEST TYPE STRING,
GZUGA TYPE STRING,
GABGA TYPE STRING,
WBEST TYPE STRING,
WGSBEST TYPE STRING,
WZUGA TYPE STRING,
WABGA TYPE STRING,
WEISB TYPE STRING,
WATP TYPE STRING,
WATP_KUM TYPE STRING,
WBESZUG TYPE STRING,
WGZUGA TYPE STRING,
WGABGA TYPE STRING,END OF T_EKKO_STR. DATA: WA_MCDISPO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MCDISPO_STR-MATNR sy-vline
WA_MCDISPO_STR-WERKS sy-vline
WA_MCDISPO_STR-DISPO sy-vline
WA_MCDISPO_STR-DISMM sy-vline
WA_MCDISPO_STR-BUKRS sy-vline
WA_MCDISPO_STR-PLAAB sy-vline
WA_MCDISPO_STR-PLANR sy-vline
WA_MCDISPO_STR-SORT0 sy-vline
WA_MCDISPO_STR-DELKZ sy-vline
WA_MCDISPO_STR-DAT00 sy-vline
WA_MCDISPO_STR-PERKZ sy-vline
WA_MCDISPO_STR-PRPER sy-vline
WA_MCDISPO_STR-ANZFD sy-vline
WA_MCDISPO_STR-EXTSU sy-vline
WA_MCDISPO_STR-MNG01 sy-vline
WA_MCDISPO_STR-MNG02 sy-vline
WA_MCDISPO_STR-MNG03 sy-vline
WA_MCDISPO_STR-MNG04 sy-vline
WA_MCDISPO_STR-MNG05 sy-vline
WA_MCDISPO_STR-MNG06 sy-vline
WA_MCDISPO_STR-MNG07 sy-vline
WA_MCDISPO_STR-ISTRW sy-vline
WA_MCDISPO_STR-SLRWX sy-vline
WA_MCDISPO_STR-MIRWX sy-vline
WA_MCDISPO_STR-MARWX sy-vline
WA_MCDISPO_STR-SLBES sy-vline
WA_MCDISPO_STR-MDBES sy-vline
WA_MCDISPO_STR-MXBES sy-vline
WA_MCDISPO_STR-TGBED sy-vline
WA_MCDISPO_STR-TGPRO sy-vline
WA_MCDISPO_STR-BERW1 sy-vline
WA_MCDISPO_STR-BERW2 sy-vline
WA_MCDISPO_STR-SSTOCK sy-vline
WA_MCDISPO_STR-ANZBV sy-vline
WA_MCDISPO_STR-AZZUG sy-vline
WA_MCDISPO_STR-ALINE sy-vline
WA_MCDISPO_STR-ELINE sy-vline
WA_MCDISPO_STR-FBYTE sy-vline
WA_MCDISPO_STR-AKZ01 sy-vline
WA_MCDISPO_STR-AKZ02 sy-vline
WA_MCDISPO_STR-AKZ03 sy-vline
WA_MCDISPO_STR-AKZ04 sy-vline
WA_MCDISPO_STR-USEX1 sy-vline
WA_MCDISPO_STR-USEX2 sy-vline
WA_MCDISPO_STR-USEX3 sy-vline
WA_MCDISPO_STR-DETAIL_ICON sy-vline
WA_MCDISPO_STR-WAERS sy-vline
WA_MCDISPO_STR-MEINS sy-vline
WA_MCDISPO_STR-EISBE sy-vline
WA_MCDISPO_STR-BESZUG sy-vline
WA_MCDISPO_STR-ANZUG sy-vline
WA_MCDISPO_STR-MZUGA sy-vline
WA_MCDISPO_STR-MABGA sy-vline
WA_MCDISPO_STR-MBEST sy-vline
WA_MCDISPO_STR-MATP sy-vline
WA_MCDISPO_STR-GSBEST sy-vline
WA_MCDISPO_STR-GZUGA sy-vline
WA_MCDISPO_STR-GABGA sy-vline
WA_MCDISPO_STR-WBEST sy-vline
WA_MCDISPO_STR-WGSBEST sy-vline
WA_MCDISPO_STR-WZUGA sy-vline
WA_MCDISPO_STR-WABGA sy-vline
WA_MCDISPO_STR-WEISB sy-vline
WA_MCDISPO_STR-WATP sy-vline
WA_MCDISPO_STR-WATP_KUM sy-vline
WA_MCDISPO_STR-WBESZUG sy-vline
WA_MCDISPO_STR-WGZUGA sy-vline
WA_MCDISPO_STR-WGABGA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.