ABAP Select data from SAP table MC46GT0CFM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MC46GT0CFM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MC46GT0CFM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MC46GT0CFM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MC46GT0CFM TYPE STANDARD TABLE OF MC46GT0CFM,
      WA_MC46GT0CFM TYPE MC46GT0CFM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MC46GT0CFM> TYPE MC46GT0CFM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MC46GT0CFM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MC46GT0CFM
  INTO TABLE IT_MC46GT0CFM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MC46GT0CFM
*  INTO TABLE @DATA(IT_MC46GT0CFM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MC46GT0CFM INDEX 1 INTO DATA(WA_MC46GT0CFM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MC46GT0CFM ASSIGNING <MC46GT0CFM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MC46GT0CFM>-ROCANCEL = 1.
<MC46GT0CFM>-CURR_FORW_TYPE = 1.
<MC46GT0CFM>-DOCUMENT = 1.
<MC46GT0CFM>-DOC_TYPE = 1.
<MC46GT0CFM>-FX_CC = 1.
ENDLOOP.

LOOP AT IT_MC46GT0CFM INTO WA_MC46GT0CFM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MC46GT0CFM-FX_CC_MIRROR, sy-vline,
WA_MC46GT0CFM-FX_CURRENCY, sy-vline,
WA_MC46GT0CFM-FX_NR, sy-vline,
WA_MC46GT0CFM-FX_NR_MIRROR, sy-vline,
WA_MC46GT0CFM-FX_VALUE, sy-vline,
WA_MC46GT0CFM-FX_VALUE_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MC46GT0CFM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MC46GT0CFM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MC46GT0CFM INTO WA_MC46GT0CFM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC46GT0CFM-DOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC46GT0CFM-DOCUMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FX_NR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC46GT0CFM-FX_NR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC46GT0CFM-FX_NR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FX_NR_MIRROR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC46GT0CFM-FX_NR_MIRROR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC46GT0CFM-FX_NR_MIRROR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MC46GT0CFM_STR,
ROCANCEL TYPE STRING,
CURR_FORW_TYPE TYPE STRING,
DOCUMENT TYPE STRING,
DOC_TYPE TYPE STRING,
FX_CC TYPE STRING,
FX_CC_MIRROR TYPE STRING,
FX_CURRENCY TYPE STRING,
FX_NR TYPE STRING,
FX_NR_MIRROR TYPE STRING,
FX_VALUE TYPE STRING,
FX_VALUE_DATE TYPE STRING,
ITEM TYPE STRING,
LOGISTIC_CC TYPE STRING,
LOGISTIC_CC_CURR TYPE STRING,
MANDT TYPE STRING,
POSN_TYPE TYPE STRING,
RISK_TYPE TYPE STRING,
SUB_ITEM TYPE STRING,
UPDKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_MC46GT0CFM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MC46GT0CFM_STR-ROCANCEL sy-vline
WA_MC46GT0CFM_STR-CURR_FORW_TYPE sy-vline
WA_MC46GT0CFM_STR-DOCUMENT sy-vline
WA_MC46GT0CFM_STR-DOC_TYPE sy-vline
WA_MC46GT0CFM_STR-FX_CC sy-vline
WA_MC46GT0CFM_STR-FX_CC_MIRROR sy-vline
WA_MC46GT0CFM_STR-FX_CURRENCY sy-vline
WA_MC46GT0CFM_STR-FX_NR sy-vline
WA_MC46GT0CFM_STR-FX_NR_MIRROR sy-vline
WA_MC46GT0CFM_STR-FX_VALUE sy-vline
WA_MC46GT0CFM_STR-FX_VALUE_DATE sy-vline
WA_MC46GT0CFM_STR-ITEM sy-vline
WA_MC46GT0CFM_STR-LOGISTIC_CC sy-vline
WA_MC46GT0CFM_STR-LOGISTIC_CC_CURR sy-vline
WA_MC46GT0CFM_STR-MANDT sy-vline
WA_MC46GT0CFM_STR-POSN_TYPE sy-vline
WA_MC46GT0CFM_STR-RISK_TYPE sy-vline
WA_MC46GT0CFM_STR-SUB_ITEM sy-vline
WA_MC46GT0CFM_STR-UPDKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.