ABAP Select data from SAP table MC45PD3LST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MC45PD3LST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MC45PD3LST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MC45PD3LST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MC45PD3LST TYPE STANDARD TABLE OF MC45PD3LST,
      WA_MC45PD3LST TYPE MC45PD3LST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MC45PD3LST> TYPE MC45PD3LST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MC45PD3LST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MC45PD3LST
  INTO TABLE IT_MC45PD3LST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MC45PD3LST
*  INTO TABLE @DATA(IT_MC45PD3LST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MC45PD3LST INDEX 1 INTO DATA(WA_MC45PD3LST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MC45PD3LST ASSIGNING <MC45PD3LST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MC45PD3LST>-ARKTX = 1.
<MC45PD3LST>-BONBAD = 1.
<MC45PD3LST>-BRGEW = 1.
<MC45PD3LST>-BRGEW_SINGLE = 1.
<MC45PD3LST>-BRTWRD = 1.
ENDLOOP.

LOOP AT IT_MC45PD3LST INTO WA_MC45PD3LST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MC45PD3LST-CHARG, sy-vline,
WA_MC45PD3LST-CONTRACT, sy-vline,
WA_MC45PD3LST-CONTRACT_TYPE, sy-vline,
WA_MC45PD3LST-EFFWRD, sy-vline,
WA_MC45PD3LST-ERDAT, sy-vline,
WA_MC45PD3LST-ERNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MC45PD3LST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MC45PD3LST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MC45PD3LST INTO WA_MC45PD3LST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC45PD3LST-CONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-CONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FPRME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC45PD3LST-FPRME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-FPRME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC45PD3LST-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHRV CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_MC45PD3LST-GJAHRV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-GJAHRV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOLIF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC45PD3LST-KOLIF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-KOLIF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC45PD3LST-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MC45PD3LST-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC45PD3LST-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC45PD3LST-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC45PD3LST-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WFKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC45PD3LST-WFKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC45PD3LST-WFKME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MC45PD3LST_STR,
ARKTX TYPE STRING,
BONBAD TYPE STRING,
BRGEW TYPE STRING,
BRGEW_SINGLE TYPE STRING,
BRTWRD TYPE STRING,
CHARG TYPE STRING,
CONTRACT TYPE STRING,
CONTRACT_TYPE TYPE STRING,
EFFWRD TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
ERZET TYPE STRING,
FPRME TYPE STRING,
FPUMN TYPE STRING,
FPUMZ TYPE STRING,
FTYPV_V TYPE STRING,
GEWEI TYPE STRING,
GJAHRV TYPE STRING,
GSBER TYPE STRING,
IDNLF TYPE STRING,
ITEMCAT TYPE STRING,
KOKRS TYPE STRING,
KOLIF TYPE STRING,
KOSTL TYPE STRING,
KOWRR TYPE STRING,
KZWI1D TYPE STRING,
KZWI2D TYPE STRING,
KZWI3D TYPE STRING,
KZWI4D TYPE STRING,
KZWI5D TYPE STRING,
KZWI6D TYPE STRING,
LFGRU TYPE STRING,
LTSNR TYPE STRING,
MATKL TYPE STRING,
MATNR TYPE STRING,
MEINS TYPE STRING,
MENGE TYPE STRING,
MTART TYPE STRING,
MWSBPD TYPE STRING,
MWSK2 TYPE STRING,
NETPR TYPE STRING,
NETWRD TYPE STRING,
NTGEW TYPE STRING,
NTGEW_SINGLE TYPE STRING,
PEINH TYPE STRING,
POSNR TYPE STRING,
POSNR_V TYPE STRING,
PRCTR TYPE STRING,
PRSDT TYPE STRING,
SKFBPD TYPE STRING,
SKTOF TYPE STRING,
UMREN TYPE STRING,
UMREZ TYPE STRING,
UPDKZ TYPE STRING,
VOLEH TYPE STRING,
VOLUM TYPE STRING,
VOLUM_SINGLE TYPE STRING,
WBELN_V TYPE STRING,
WERKS TYPE STRING,
WFKME TYPE STRING,END OF T_EKKO_STR. DATA: WA_MC45PD3LST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MC45PD3LST_STR-ARKTX sy-vline
WA_MC45PD3LST_STR-BONBAD sy-vline
WA_MC45PD3LST_STR-BRGEW sy-vline
WA_MC45PD3LST_STR-BRGEW_SINGLE sy-vline
WA_MC45PD3LST_STR-BRTWRD sy-vline
WA_MC45PD3LST_STR-CHARG sy-vline
WA_MC45PD3LST_STR-CONTRACT sy-vline
WA_MC45PD3LST_STR-CONTRACT_TYPE sy-vline
WA_MC45PD3LST_STR-EFFWRD sy-vline
WA_MC45PD3LST_STR-ERDAT sy-vline
WA_MC45PD3LST_STR-ERNAM sy-vline
WA_MC45PD3LST_STR-ERZET sy-vline
WA_MC45PD3LST_STR-FPRME sy-vline
WA_MC45PD3LST_STR-FPUMN sy-vline
WA_MC45PD3LST_STR-FPUMZ sy-vline
WA_MC45PD3LST_STR-FTYPV_V sy-vline
WA_MC45PD3LST_STR-GEWEI sy-vline
WA_MC45PD3LST_STR-GJAHRV sy-vline
WA_MC45PD3LST_STR-GSBER sy-vline
WA_MC45PD3LST_STR-IDNLF sy-vline
WA_MC45PD3LST_STR-ITEMCAT sy-vline
WA_MC45PD3LST_STR-KOKRS sy-vline
WA_MC45PD3LST_STR-KOLIF sy-vline
WA_MC45PD3LST_STR-KOSTL sy-vline
WA_MC45PD3LST_STR-KOWRR sy-vline
WA_MC45PD3LST_STR-KZWI1D sy-vline
WA_MC45PD3LST_STR-KZWI2D sy-vline
WA_MC45PD3LST_STR-KZWI3D sy-vline
WA_MC45PD3LST_STR-KZWI4D sy-vline
WA_MC45PD3LST_STR-KZWI5D sy-vline
WA_MC45PD3LST_STR-KZWI6D sy-vline
WA_MC45PD3LST_STR-LFGRU sy-vline
WA_MC45PD3LST_STR-LTSNR sy-vline
WA_MC45PD3LST_STR-MATKL sy-vline
WA_MC45PD3LST_STR-MATNR sy-vline
WA_MC45PD3LST_STR-MEINS sy-vline
WA_MC45PD3LST_STR-MENGE sy-vline
WA_MC45PD3LST_STR-MTART sy-vline
WA_MC45PD3LST_STR-MWSBPD sy-vline
WA_MC45PD3LST_STR-MWSK2 sy-vline
WA_MC45PD3LST_STR-NETPR sy-vline
WA_MC45PD3LST_STR-NETWRD sy-vline
WA_MC45PD3LST_STR-NTGEW sy-vline
WA_MC45PD3LST_STR-NTGEW_SINGLE sy-vline
WA_MC45PD3LST_STR-PEINH sy-vline
WA_MC45PD3LST_STR-POSNR sy-vline
WA_MC45PD3LST_STR-POSNR_V sy-vline
WA_MC45PD3LST_STR-PRCTR sy-vline
WA_MC45PD3LST_STR-PRSDT sy-vline
WA_MC45PD3LST_STR-SKFBPD sy-vline
WA_MC45PD3LST_STR-SKTOF sy-vline
WA_MC45PD3LST_STR-UMREN sy-vline
WA_MC45PD3LST_STR-UMREZ sy-vline
WA_MC45PD3LST_STR-UPDKZ sy-vline
WA_MC45PD3LST_STR-VOLEH sy-vline
WA_MC45PD3LST_STR-VOLUM sy-vline
WA_MC45PD3LST_STR-VOLUM_SINGLE sy-vline
WA_MC45PD3LST_STR-WBELN_V sy-vline
WA_MC45PD3LST_STR-WERKS sy-vline
WA_MC45PD3LST_STR-WFKME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.