ABAP Select data from SAP table MC29V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MC29V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MC29V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MC29V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MC29V TYPE STANDARD TABLE OF MC29V,
      WA_MC29V TYPE MC29V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MC29V> TYPE MC29V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MC29V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MC29V
  INTO TABLE IT_MC29V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MC29V
*  INTO TABLE @DATA(IT_MC29V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MC29V INDEX 1 INTO DATA(WA_MC29V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MC29V ASSIGNING <MC29V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MC29V>-MANDT = 1.
<MC29V>-MATNR = 1.
<MC29V>-WERKS = 1.
<MC29V>-LVORM = 1.
<MC29V>-AENAM = 1.
ENDLOOP.

LOOP AT IT_MC29V INTO WA_MC29V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MC29V-AESZN, sy-vline,
WA_MC29V-BLANZ, sy-vline,
WA_MC29V-BLATT, sy-vline,
WA_MC29V-DISST, sy-vline,
WA_MC29V-ERNAM, sy-vline,
WA_MC29V-ERSDA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MC29V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MC29V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MC29V INTO WA_MC29V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MC29V-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC29V-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC29V-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC29V-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field AUSME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC29V-AUSME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-AUSME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field NFMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MC29V-NFMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-NFMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field STDPD CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MC29V-STDPD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-STDPD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FRTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC29V-FRTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-FRTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC29V-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC29V-PRCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MC29V_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LVORM TYPE STRING,
AENAM TYPE STRING,
AESZN TYPE STRING,
BLANZ TYPE STRING,
BLATT TYPE STRING,
DISST TYPE STRING,
ERNAM TYPE STRING,
ERSDA TYPE STRING,
FERTH TYPE STRING,
BRGEW TYPE STRING,
NTGEW TYPE STRING,
GEWEI TYPE STRING,
GROES TYPE STRING,
LABOR TYPE STRING,
LAEDA TYPE STRING,
MATKL TYPE STRING,
MBRSH TYPE STRING,
MEINS TYPE STRING,
MTART TYPE STRING,
NORMT TYPE STRING,
VPSTA TYPE STRING,
VOLEH TYPE STRING,
VOLUM TYPE STRING,
WRKST TYPE STRING,
ZEIAR TYPE STRING,
ZEIFO TYPE STRING,
ZEINR TYPE STRING,
ZEIVR TYPE STRING,
ATTYP TYPE STRING,
ALTSL TYPE STRING,
AUSME TYPE STRING,
AUSSS TYPE STRING,
KZAUS TYPE STRING,
AUSDT TYPE STRING,
NFMAT TYPE STRING,
SBDKZ TYPE STRING,
MMSTA TYPE STRING,
MMSTD TYPE STRING,
BESKZ TYPE STRING,
DISMM TYPE STRING,
SOBSL TYPE STRING,
DZEIT TYPE STRING,
PLIFZ TYPE STRING,
RGEKZ TYPE STRING,
RUEZT TYPE STRING,
TRANZ TYPE STRING,
WEBAZ TYPE STRING,
BASMG TYPE STRING,
BEARZ TYPE STRING,
EKGRP TYPE STRING,
KAUSF TYPE STRING,
LGPRO TYPE STRING,
KZREV TYPE STRING,
KZDKZ TYPE STRING,
KZKFG TYPE STRING,
STDPD TYPE STRING,
CUOBJ TYPE STRING,
SOBSK TYPE STRING,
KZKUP TYPE STRING,
SCHGT TYPE STRING,
EPRIO TYPE STRING,
STAWN TYPE STRING,
PREFE TYPE STRING,
PRENE TYPE STRING,
XCHAR TYPE STRING,
XCHPF TYPE STRING,
KZECH TYPE STRING,
SERNP TYPE STRING,
MISKZ TYPE STRING,
MTVFP TYPE STRING,
FRTME TYPE STRING,
KZWSM TYPE STRING,
PRCTR TYPE STRING,
SERLV TYPE STRING,
MSTAE TYPE STRING,
MSTDE TYPE STRING,
VSPVB TYPE STRING,
KZBED TYPE STRING,
KZEFF TYPE STRING,
FXPRU TYPE STRING,
APOKZ TYPE STRING,
AHDIS TYPE STRING,
USEQU TYPE STRING,
BFLME TYPE STRING,END OF T_EKKO_STR. DATA: WA_MC29V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MC29V_STR-MANDT sy-vline
WA_MC29V_STR-MATNR sy-vline
WA_MC29V_STR-WERKS sy-vline
WA_MC29V_STR-LVORM sy-vline
WA_MC29V_STR-AENAM sy-vline
WA_MC29V_STR-AESZN sy-vline
WA_MC29V_STR-BLANZ sy-vline
WA_MC29V_STR-BLATT sy-vline
WA_MC29V_STR-DISST sy-vline
WA_MC29V_STR-ERNAM sy-vline
WA_MC29V_STR-ERSDA sy-vline
WA_MC29V_STR-FERTH sy-vline
WA_MC29V_STR-BRGEW sy-vline
WA_MC29V_STR-NTGEW sy-vline
WA_MC29V_STR-GEWEI sy-vline
WA_MC29V_STR-GROES sy-vline
WA_MC29V_STR-LABOR sy-vline
WA_MC29V_STR-LAEDA sy-vline
WA_MC29V_STR-MATKL sy-vline
WA_MC29V_STR-MBRSH sy-vline
WA_MC29V_STR-MEINS sy-vline
WA_MC29V_STR-MTART sy-vline
WA_MC29V_STR-NORMT sy-vline
WA_MC29V_STR-VPSTA sy-vline
WA_MC29V_STR-VOLEH sy-vline
WA_MC29V_STR-VOLUM sy-vline
WA_MC29V_STR-WRKST sy-vline
WA_MC29V_STR-ZEIAR sy-vline
WA_MC29V_STR-ZEIFO sy-vline
WA_MC29V_STR-ZEINR sy-vline
WA_MC29V_STR-ZEIVR sy-vline
WA_MC29V_STR-ATTYP sy-vline
WA_MC29V_STR-ALTSL sy-vline
WA_MC29V_STR-AUSME sy-vline
WA_MC29V_STR-AUSSS sy-vline
WA_MC29V_STR-KZAUS sy-vline
WA_MC29V_STR-AUSDT sy-vline
WA_MC29V_STR-NFMAT sy-vline
WA_MC29V_STR-SBDKZ sy-vline
WA_MC29V_STR-MMSTA sy-vline
WA_MC29V_STR-MMSTD sy-vline
WA_MC29V_STR-BESKZ sy-vline
WA_MC29V_STR-DISMM sy-vline
WA_MC29V_STR-SOBSL sy-vline
WA_MC29V_STR-DZEIT sy-vline
WA_MC29V_STR-PLIFZ sy-vline
WA_MC29V_STR-RGEKZ sy-vline
WA_MC29V_STR-RUEZT sy-vline
WA_MC29V_STR-TRANZ sy-vline
WA_MC29V_STR-WEBAZ sy-vline
WA_MC29V_STR-BASMG sy-vline
WA_MC29V_STR-BEARZ sy-vline
WA_MC29V_STR-EKGRP sy-vline
WA_MC29V_STR-KAUSF sy-vline
WA_MC29V_STR-LGPRO sy-vline
WA_MC29V_STR-KZREV sy-vline
WA_MC29V_STR-KZDKZ sy-vline
WA_MC29V_STR-KZKFG sy-vline
WA_MC29V_STR-STDPD sy-vline
WA_MC29V_STR-CUOBJ sy-vline
WA_MC29V_STR-SOBSK sy-vline
WA_MC29V_STR-KZKUP sy-vline
WA_MC29V_STR-SCHGT sy-vline
WA_MC29V_STR-EPRIO sy-vline
WA_MC29V_STR-STAWN sy-vline
WA_MC29V_STR-PREFE sy-vline
WA_MC29V_STR-PRENE sy-vline
WA_MC29V_STR-XCHAR sy-vline
WA_MC29V_STR-XCHPF sy-vline
WA_MC29V_STR-KZECH sy-vline
WA_MC29V_STR-SERNP sy-vline
WA_MC29V_STR-MISKZ sy-vline
WA_MC29V_STR-MTVFP sy-vline
WA_MC29V_STR-FRTME sy-vline
WA_MC29V_STR-KZWSM sy-vline
WA_MC29V_STR-PRCTR sy-vline
WA_MC29V_STR-SERLV sy-vline
WA_MC29V_STR-MSTAE sy-vline
WA_MC29V_STR-MSTDE sy-vline
WA_MC29V_STR-VSPVB sy-vline
WA_MC29V_STR-KZBED sy-vline
WA_MC29V_STR-KZEFF sy-vline
WA_MC29V_STR-FXPRU sy-vline
WA_MC29V_STR-APOKZ sy-vline
WA_MC29V_STR-AHDIS sy-vline
WA_MC29V_STR-USEQU sy-vline
WA_MC29V_STR-BFLME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.