ABAP Select data from SAP table MC18I01NTF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MC18I01NTF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MC18I01NTF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MC18I01NTF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MC18I01NTF TYPE STANDARD TABLE OF MC18I01NTF,
      WA_MC18I01NTF TYPE MC18I01NTF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MC18I01NTF> TYPE MC18I01NTF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MC18I01NTF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MC18I01NTF
  INTO TABLE IT_MC18I01NTF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MC18I01NTF
*  INTO TABLE @DATA(IT_MC18I01NTF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MC18I01NTF INDEX 1 INTO DATA(WA_MC18I01NTF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MC18I01NTF ASSIGNING <MC18I01NTF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MC18I01NTF>-AUSBS = 1.
<MC18I01NTF>-AUSVN = 1.
<MC18I01NTF>-AUSZT1 = 1.
<MC18I01NTF>-AUZTB = 1.
<MC18I01NTF>-AUZTV = 1.
ENDLOOP.

LOOP AT IT_MC18I01NTF INTO WA_MC18I01NTF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MC18I01NTF-BAUTL_HD, sy-vline,
WA_MC18I01NTF-EHTAG, sy-vline,
WA_MC18I01NTF-EQUNR, sy-vline,
WA_MC18I01NTF-HERKZ, sy-vline,
WA_MC18I01NTF-KUNUM, sy-vline,
WA_MC18I01NTF-MSAUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MC18I01NTF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MC18I01NTF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MC18I01NTF INTO WA_MC18I01NTF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field BAUTL_HD CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MC18I01NTF-BAUTL_HD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC18I01NTF-BAUTL_HD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHTAG CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC18I01NTF-EHTAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC18I01NTF-EHTAG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC18I01NTF-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC18I01NTF-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC18I01NTF-KUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC18I01NTF-KUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC18I01NTF-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC18I01NTF-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC18I01NTF-SUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC18I01NTF-SUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_MC18I01NTF-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC18I01NTF-TPLNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MC18I01NTF_STR,
AUSBS TYPE STRING,
AUSVN TYPE STRING,
AUSZT1 TYPE STRING,
AUZTB TYPE STRING,
AUZTV TYPE STRING,
BAUTL_HD TYPE STRING,
EHTAG TYPE STRING,
EQUNR TYPE STRING,
HERKZ TYPE STRING,
KUNUM TYPE STRING,
MSAUS TYPE STRING,
QMART TYPE STRING,
QMDAT TYPE STRING,
QMNUM TYPE STRING,
SPART TYPE STRING,
SUMDLZT TYPE STRING,
SUNIT TYPE STRING,
TPLNR TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
ZHLERL_TE TYPE STRING,
ZHLMAOF TYPE STRING,
ZHLMASS TYPE STRING,
ZHLMELD TYPE STRING,
ZHLMERF TYPE STRING,
ZHLMOFN TYPE STRING,END OF T_EKKO_STR. DATA: WA_MC18I01NTF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MC18I01NTF_STR-AUSBS sy-vline
WA_MC18I01NTF_STR-AUSVN sy-vline
WA_MC18I01NTF_STR-AUSZT1 sy-vline
WA_MC18I01NTF_STR-AUZTB sy-vline
WA_MC18I01NTF_STR-AUZTV sy-vline
WA_MC18I01NTF_STR-BAUTL_HD sy-vline
WA_MC18I01NTF_STR-EHTAG sy-vline
WA_MC18I01NTF_STR-EQUNR sy-vline
WA_MC18I01NTF_STR-HERKZ sy-vline
WA_MC18I01NTF_STR-KUNUM sy-vline
WA_MC18I01NTF_STR-MSAUS sy-vline
WA_MC18I01NTF_STR-QMART sy-vline
WA_MC18I01NTF_STR-QMDAT sy-vline
WA_MC18I01NTF_STR-QMNUM sy-vline
WA_MC18I01NTF_STR-SPART sy-vline
WA_MC18I01NTF_STR-SUMDLZT sy-vline
WA_MC18I01NTF_STR-SUNIT sy-vline
WA_MC18I01NTF_STR-TPLNR sy-vline
WA_MC18I01NTF_STR-VKORG sy-vline
WA_MC18I01NTF_STR-VTWEG sy-vline
WA_MC18I01NTF_STR-ZHLERL_TE sy-vline
WA_MC18I01NTF_STR-ZHLMAOF sy-vline
WA_MC18I01NTF_STR-ZHLMASS sy-vline
WA_MC18I01NTF_STR-ZHLMELD sy-vline
WA_MC18I01NTF_STR-ZHLMERF sy-vline
WA_MC18I01NTF_STR-ZHLMOFN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.