ABAP Select data from SAP table MC11VA0SCL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MC11VA0SCL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MC11VA0SCL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MC11VA0SCL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MC11VA0SCL TYPE STANDARD TABLE OF MC11VA0SCL,
      WA_MC11VA0SCL TYPE MC11VA0SCL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MC11VA0SCL> TYPE MC11VA0SCL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MC11VA0SCL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MC11VA0SCL
  INTO TABLE IT_MC11VA0SCL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MC11VA0SCL
*  INTO TABLE @DATA(IT_MC11VA0SCL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MC11VA0SCL INDEX 1 INTO DATA(WA_MC11VA0SCL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MC11VA0SCL ASSIGNING <MC11VA0SCL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MC11VA0SCL>-ROCANCEL = 1.
<MC11VA0SCL>-VBELN = 1.
<MC11VA0SCL>-ABSTA = 1.
<MC11VA0SCL>-POSNR = 1.
<MC11VA0SCL>-UVALL = 1.
ENDLOOP.

LOOP AT IT_MC11VA0SCL INTO WA_MC11VA0SCL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MC11VA0SCL-UVFAK, sy-vline,
WA_MC11VA0SCL-UVPRS, sy-vline,
WA_MC11VA0SCL-UVVLK, sy-vline,
WA_MC11VA0SCL-BMENG, sy-vline,
WA_MC11VA0SCL-CMENG, sy-vline,
WA_MC11VA0SCL-EDATU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MC11VA0SCL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MC11VA0SCL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MC11VA0SCL INTO WA_MC11VA0SCL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11VA0SCL-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-VRKME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AUART, internal->external for field AUART CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_MC11VA0SCL-AUART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-AUART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11VA0SCL-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field CMKUA CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-CMKUA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-CMKUA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_MC11VA0SCL-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field KMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-KMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-KMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MC11VA0SCL-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATWA CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MC11VA0SCL-MATWA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-MATWA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PKUNRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11VA0SCL-PKUNRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-PKUNRE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PKUNRG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11VA0SCL-PKUNRG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-PKUNRG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PKUNWE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11VA0SCL-PKUNWE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-PKUNWE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PSPDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11VA0SCL-PSPDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-PSPDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field STCUR CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-STCUR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-STCUR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZIEME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-ZIEME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-ZIEME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSK CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_MC11VA0SCL-KURSK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-KURSK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field PS_POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_MC11VA0SCL-PS_POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-PS_POSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11VA0SCL-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11VA0SCL-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MC11VA0SCL_STR,
ROCANCEL TYPE STRING,
VBELN TYPE STRING,
ABSTA TYPE STRING,
POSNR TYPE STRING,
UVALL TYPE STRING,
UVFAK TYPE STRING,
UVPRS TYPE STRING,
UVVLK TYPE STRING,
BMENG TYPE STRING,
CMENG TYPE STRING,
EDATU TYPE STRING,
ETENR TYPE STRING,
ETTYP TYPE STRING,
LDDAT TYPE STRING,
LIFSP TYPE STRING,
LMENG TYPE STRING,
MBDAT TYPE STRING,
MEINS TYPE STRING,
TDDAT TYPE STRING,
VRKME TYPE STRING,
WADAT TYPE STRING,
WLDATBE TYPE STRING,
WMENG TYPE STRING,
ANGDT TYPE STRING,
AUART TYPE STRING,
AUGRU TYPE STRING,
BNDDT TYPE STRING,
BUKRS TYPE STRING,
FAKSK TYPE STRING,
HWAER TYPE STRING,
KUNNR TYPE STRING,
KURST TYPE STRING,
KVGR1 TYPE STRING,
KVGR2 TYPE STRING,
KVGR3 TYPE STRING,
KVGR4 TYPE STRING,
KVGR5 TYPE STRING,
LIFSK TYPE STRING,
STWAE TYPE STRING,
VBTYP TYPE STRING,
VKBUR TYPE STRING,
VKGRP TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
ABGRU TYPE STRING,
AEDAT TYPE STRING,
AWAHR TYPE STRING,
CHARG TYPE STRING,
CMKUA TYPE STRING,
EAN11 TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
ERZET TYPE STRING,
FAKSP TYPE STRING,
GEWEI TYPE STRING,
KMEIN TYPE STRING,
KPEIN TYPE STRING,
LGORT TYPE STRING,
MATKL TYPE STRING,
MATNR TYPE STRING,
MATWA TYPE STRING,
MVGR1 TYPE STRING,
MVGR2 TYPE STRING,
MVGR3 TYPE STRING,
MVGR4 TYPE STRING,
MVGR5 TYPE STRING,
NETPR TYPE STRING,
PABLA TYPE STRING,
PKUNRE TYPE STRING,
PKUNRG TYPE STRING,
PKUNWE TYPE STRING,
PRODH TYPE STRING,
PSPDNR TYPE STRING,
PSTYV TYPE STRING,
PVRTNR TYPE STRING,
ROUTE TYPE STRING,
SPART TYPE STRING,
STADAT TYPE STRING,
STCUR TYPE STRING,
SUGRD TYPE STRING,
UMVKN TYPE STRING,
UMVKZ TYPE STRING,
UMZIN TYPE STRING,
UMZIZ TYPE STRING,
VDATU TYPE STRING,
VGTYP TYPE STRING,
VOLEH TYPE STRING,
VSTEL TYPE STRING,
WAERK TYPE STRING,
WERKS TYPE STRING,
ZIEME TYPE STRING,
BZIRK TYPE STRING,
FBUDA TYPE STRING,
FKDAT TYPE STRING,
INCO1 TYPE STRING,
INCO2 TYPE STRING,
KDGRP TYPE STRING,
KTGRD TYPE STRING,
KURSK TYPE STRING,
KURSK_DAT TYPE STRING,
PRSDT TYPE STRING,
WAERK_VBAK TYPE STRING,
SPARA TYPE STRING,
VGTYP_AK TYPE STRING,
PS_POSID TYPE STRING,
PERIV TYPE STRING,
MCEX_APCAMPAIGN TYPE STRING,
APOPLANNED TYPE STRING,
FACELOC TYPE STRING,
FLOCTYPE TYPE STRING,
EXECLOC TYPE STRING,
ELOCTYPE TYPE STRING,
LOGSYS TYPE STRING,
VWPOS TYPE STRING,
STOCKLOC TYPE STRING,
SLOCTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_MC11VA0SCL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MC11VA0SCL_STR-ROCANCEL sy-vline
WA_MC11VA0SCL_STR-VBELN sy-vline
WA_MC11VA0SCL_STR-ABSTA sy-vline
WA_MC11VA0SCL_STR-POSNR sy-vline
WA_MC11VA0SCL_STR-UVALL sy-vline
WA_MC11VA0SCL_STR-UVFAK sy-vline
WA_MC11VA0SCL_STR-UVPRS sy-vline
WA_MC11VA0SCL_STR-UVVLK sy-vline
WA_MC11VA0SCL_STR-BMENG sy-vline
WA_MC11VA0SCL_STR-CMENG sy-vline
WA_MC11VA0SCL_STR-EDATU sy-vline
WA_MC11VA0SCL_STR-ETENR sy-vline
WA_MC11VA0SCL_STR-ETTYP sy-vline
WA_MC11VA0SCL_STR-LDDAT sy-vline
WA_MC11VA0SCL_STR-LIFSP sy-vline
WA_MC11VA0SCL_STR-LMENG sy-vline
WA_MC11VA0SCL_STR-MBDAT sy-vline
WA_MC11VA0SCL_STR-MEINS sy-vline
WA_MC11VA0SCL_STR-TDDAT sy-vline
WA_MC11VA0SCL_STR-VRKME sy-vline
WA_MC11VA0SCL_STR-WADAT sy-vline
WA_MC11VA0SCL_STR-WLDATBE sy-vline
WA_MC11VA0SCL_STR-WMENG sy-vline
WA_MC11VA0SCL_STR-ANGDT sy-vline
WA_MC11VA0SCL_STR-AUART sy-vline
WA_MC11VA0SCL_STR-AUGRU sy-vline
WA_MC11VA0SCL_STR-BNDDT sy-vline
WA_MC11VA0SCL_STR-BUKRS sy-vline
WA_MC11VA0SCL_STR-FAKSK sy-vline
WA_MC11VA0SCL_STR-HWAER sy-vline
WA_MC11VA0SCL_STR-KUNNR sy-vline
WA_MC11VA0SCL_STR-KURST sy-vline
WA_MC11VA0SCL_STR-KVGR1 sy-vline
WA_MC11VA0SCL_STR-KVGR2 sy-vline
WA_MC11VA0SCL_STR-KVGR3 sy-vline
WA_MC11VA0SCL_STR-KVGR4 sy-vline
WA_MC11VA0SCL_STR-KVGR5 sy-vline
WA_MC11VA0SCL_STR-LIFSK sy-vline
WA_MC11VA0SCL_STR-STWAE sy-vline
WA_MC11VA0SCL_STR-VBTYP sy-vline
WA_MC11VA0SCL_STR-VKBUR sy-vline
WA_MC11VA0SCL_STR-VKGRP sy-vline
WA_MC11VA0SCL_STR-VKORG sy-vline
WA_MC11VA0SCL_STR-VTWEG sy-vline
WA_MC11VA0SCL_STR-ABGRU sy-vline
WA_MC11VA0SCL_STR-AEDAT sy-vline
WA_MC11VA0SCL_STR-AWAHR sy-vline
WA_MC11VA0SCL_STR-CHARG sy-vline
WA_MC11VA0SCL_STR-CMKUA sy-vline
WA_MC11VA0SCL_STR-EAN11 sy-vline
WA_MC11VA0SCL_STR-ERDAT sy-vline
WA_MC11VA0SCL_STR-ERNAM sy-vline
WA_MC11VA0SCL_STR-ERZET sy-vline
WA_MC11VA0SCL_STR-FAKSP sy-vline
WA_MC11VA0SCL_STR-GEWEI sy-vline
WA_MC11VA0SCL_STR-KMEIN sy-vline
WA_MC11VA0SCL_STR-KPEIN sy-vline
WA_MC11VA0SCL_STR-LGORT sy-vline
WA_MC11VA0SCL_STR-MATKL sy-vline
WA_MC11VA0SCL_STR-MATNR sy-vline
WA_MC11VA0SCL_STR-MATWA sy-vline
WA_MC11VA0SCL_STR-MVGR1 sy-vline
WA_MC11VA0SCL_STR-MVGR2 sy-vline
WA_MC11VA0SCL_STR-MVGR3 sy-vline
WA_MC11VA0SCL_STR-MVGR4 sy-vline
WA_MC11VA0SCL_STR-MVGR5 sy-vline
WA_MC11VA0SCL_STR-NETPR sy-vline
WA_MC11VA0SCL_STR-PABLA sy-vline
WA_MC11VA0SCL_STR-PKUNRE sy-vline
WA_MC11VA0SCL_STR-PKUNRG sy-vline
WA_MC11VA0SCL_STR-PKUNWE sy-vline
WA_MC11VA0SCL_STR-PRODH sy-vline
WA_MC11VA0SCL_STR-PSPDNR sy-vline
WA_MC11VA0SCL_STR-PSTYV sy-vline
WA_MC11VA0SCL_STR-PVRTNR sy-vline
WA_MC11VA0SCL_STR-ROUTE sy-vline
WA_MC11VA0SCL_STR-SPART sy-vline
WA_MC11VA0SCL_STR-STADAT sy-vline
WA_MC11VA0SCL_STR-STCUR sy-vline
WA_MC11VA0SCL_STR-SUGRD sy-vline
WA_MC11VA0SCL_STR-UMVKN sy-vline
WA_MC11VA0SCL_STR-UMVKZ sy-vline
WA_MC11VA0SCL_STR-UMZIN sy-vline
WA_MC11VA0SCL_STR-UMZIZ sy-vline
WA_MC11VA0SCL_STR-VDATU sy-vline
WA_MC11VA0SCL_STR-VGTYP sy-vline
WA_MC11VA0SCL_STR-VOLEH sy-vline
WA_MC11VA0SCL_STR-VSTEL sy-vline
WA_MC11VA0SCL_STR-WAERK sy-vline
WA_MC11VA0SCL_STR-WERKS sy-vline
WA_MC11VA0SCL_STR-ZIEME sy-vline
WA_MC11VA0SCL_STR-BZIRK sy-vline
WA_MC11VA0SCL_STR-FBUDA sy-vline
WA_MC11VA0SCL_STR-FKDAT sy-vline
WA_MC11VA0SCL_STR-INCO1 sy-vline
WA_MC11VA0SCL_STR-INCO2 sy-vline
WA_MC11VA0SCL_STR-KDGRP sy-vline
WA_MC11VA0SCL_STR-KTGRD sy-vline
WA_MC11VA0SCL_STR-KURSK sy-vline
WA_MC11VA0SCL_STR-KURSK_DAT sy-vline
WA_MC11VA0SCL_STR-PRSDT sy-vline
WA_MC11VA0SCL_STR-WAERK_VBAK sy-vline
WA_MC11VA0SCL_STR-SPARA sy-vline
WA_MC11VA0SCL_STR-VGTYP_AK sy-vline
WA_MC11VA0SCL_STR-PS_POSID sy-vline
WA_MC11VA0SCL_STR-PERIV sy-vline
WA_MC11VA0SCL_STR-MCEX_APCAMPAIGN sy-vline
WA_MC11VA0SCL_STR-APOPLANNED sy-vline
WA_MC11VA0SCL_STR-FACELOC sy-vline
WA_MC11VA0SCL_STR-FLOCTYPE sy-vline
WA_MC11VA0SCL_STR-EXECLOC sy-vline
WA_MC11VA0SCL_STR-ELOCTYPE sy-vline
WA_MC11VA0SCL_STR-LOGSYS sy-vline
WA_MC11VA0SCL_STR-VWPOS sy-vline
WA_MC11VA0SCL_STR-STOCKLOC sy-vline
WA_MC11VA0SCL_STR-SLOCTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.