ABAP Select data from SAP table MBVMB61V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MBVMB61V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MBVMB61V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MBVMB61V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MBVMB61V TYPE STANDARD TABLE OF MBVMB61V,
      WA_MBVMB61V TYPE MBVMB61V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MBVMB61V> TYPE MBVMB61V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MBVMB61V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MBVMB61V
  INTO TABLE IT_MBVMB61V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MBVMB61V
*  INTO TABLE @DATA(IT_MBVMB61V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MBVMB61V INDEX 1 INTO DATA(WA_MBVMB61V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MBVMB61V ASSIGNING <MBVMB61V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MBVMB61V>-MANDT = 1.
<MBVMB61V>-MATNR = 1.
<MBVMB61V>-BWKEY = 1.
<MBVMB61V>-BWTAR = 1.
<MBVMB61V>-LVORM = 1.
ENDLOOP.

LOOP AT IT_MBVMB61V INTO WA_MBVMB61V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MBVMB61V-VPRSV, sy-vline,
WA_MBVMB61V-VERPR, sy-vline,
WA_MBVMB61V-STPRS, sy-vline,
WA_MBVMB61V-PEINH, sy-vline,
WA_MBVMB61V-BKLAS, sy-vline,
WA_MBVMB61V-PSTAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MBVMB61V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MBVMB61V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MBVMB61V INTO WA_MBVMB61V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MBVMB61V-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MBVMB61V-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MBVMB61V_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
BWKEY TYPE STRING,
BWTAR TYPE STRING,
LVORM TYPE STRING,
VPRSV TYPE STRING,
VERPR TYPE STRING,
STPRS TYPE STRING,
PEINH TYPE STRING,
BKLAS TYPE STRING,
PSTAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_MBVMB61V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MBVMB61V_STR-MANDT sy-vline
WA_MBVMB61V_STR-MATNR sy-vline
WA_MBVMB61V_STR-BWKEY sy-vline
WA_MBVMB61V_STR-BWTAR sy-vline
WA_MBVMB61V_STR-LVORM sy-vline
WA_MBVMB61V_STR-VPRSV sy-vline
WA_MBVMB61V_STR-VERPR sy-vline
WA_MBVMB61V_STR-STPRS sy-vline
WA_MBVMB61V_STR-PEINH sy-vline
WA_MBVMB61V_STR-BKLAS sy-vline
WA_MBVMB61V_STR-PSTAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.