ABAP Select data from SAP table MAINTORDCONFMS_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MAINTORDCONFMS_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MAINTORDCONFMS_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MAINTORDCONFMS_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MAINTORDCONFMS_D TYPE STANDARD TABLE OF MAINTORDCONFMS_D,
      WA_MAINTORDCONFMS_D TYPE MAINTORDCONFMS_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MAINTORDCONFMS_D> TYPE MAINTORDCONFMS_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MAINTORDCONFMS_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MAINTORDCONFMS_D
  INTO TABLE IT_MAINTORDCONFMS_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MAINTORDCONFMS_D
*  INTO TABLE @DATA(IT_MAINTORDCONFMS_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MAINTORDCONFMS_D INDEX 1 INTO DATA(WA_MAINTORDCONFMS_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MAINTORDCONFMS_D ASSIGNING <MAINTORDCONFMS_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MAINTORDCONFMS_D>-MANDT = 1.
<MAINTORDCONFMS_D>-DRAFTUUID = 1.
<MAINTORDCONFMS_D>-PARENTDRAFTUUID = 1.
<MAINTORDCONFMS_D>-MAINTORDERCONF = 1.
<MAINTORDCONFMS_D>-MAINTORDERCONFCNTRVALUE = 1.
ENDLOOP.

LOOP AT IT_MAINTORDCONFMS_D INTO WA_MAINTORDCONFMS_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MAINTORDCONFMS_D-MAINTENANCEORDER, sy-vline,
WA_MAINTORDCONFMS_D-MAINTENANCEORDEROPERATION, sy-vline,
WA_MAINTORDCONFMS_D-MAINTENANCEORDERSUBOPERATION, sy-vline,
WA_MAINTORDCONFMS_D-SYSTEMMESSAGETYPE, sy-vline,
WA_MAINTORDCONFMS_D-SYSTEMMESSAGEIDENTIFICATION, sy-vline,
WA_MAINTORDCONFMS_D-SYSTEMMESSAGENUMBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MAINTORDCONFMS_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MAINTORDCONFMS_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MAINTORDCONFMS_D INTO WA_MAINTORDCONFMS_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MAINTENANCEORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MAINTORDCONFMS_D-MAINTENANCEORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MAINTORDCONFMS_D-MAINTENANCEORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field MAINTENANCEORDEROPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MAINTORDCONFMS_D-MAINTENANCEORDEROPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MAINTORDCONFMS_D-MAINTENANCEORDEROPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field MAINTENANCEORDERSUBOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MAINTORDCONFMS_D-MAINTENANCEORDERSUBOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MAINTORDCONFMS_D-MAINTENANCEORDERSUBOPERATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MAINTORDCONFMS_D_STR,
MANDT TYPE STRING,
DRAFTUUID TYPE STRING,
PARENTDRAFTUUID TYPE STRING,
MAINTORDERCONF TYPE STRING,
MAINTORDERCONFCNTRVALUE TYPE STRING,
MAINTENANCEORDER TYPE STRING,
MAINTENANCEORDEROPERATION TYPE STRING,
MAINTENANCEORDERSUBOPERATION TYPE STRING,
SYSTEMMESSAGETYPE TYPE STRING,
SYSTEMMESSAGEIDENTIFICATION TYPE STRING,
SYSTEMMESSAGENUMBER TYPE STRING,
SYSTEMMESSAGEVARIABLE1 TYPE STRING,
SYSTEMMESSAGEVARIABLE2 TYPE STRING,
SYSTEMMESSAGEVARIABLE3 TYPE STRING,
SYSTEMMESSAGEVARIABLE4 TYPE STRING,
SYSTEMMESSAGETEXT TYPE STRING,
ENTEREDBYUSER TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_MAINTORDCONFMS_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MAINTORDCONFMS_D_STR-MANDT sy-vline
WA_MAINTORDCONFMS_D_STR-DRAFTUUID sy-vline
WA_MAINTORDCONFMS_D_STR-PARENTDRAFTUUID sy-vline
WA_MAINTORDCONFMS_D_STR-MAINTORDERCONF sy-vline
WA_MAINTORDCONFMS_D_STR-MAINTORDERCONFCNTRVALUE sy-vline
WA_MAINTORDCONFMS_D_STR-MAINTENANCEORDER sy-vline
WA_MAINTORDCONFMS_D_STR-MAINTENANCEORDEROPERATION sy-vline
WA_MAINTORDCONFMS_D_STR-MAINTENANCEORDERSUBOPERATION sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGETYPE sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGEIDENTIFICATION sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGENUMBER sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGEVARIABLE1 sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGEVARIABLE2 sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGEVARIABLE3 sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGEVARIABLE4 sy-vline
WA_MAINTORDCONFMS_D_STR-SYSTEMMESSAGETEXT sy-vline
WA_MAINTORDCONFMS_D_STR-ENTEREDBYUSER sy-vline
WA_MAINTORDCONFMS_D_STR-HASACTIVEENTITY sy-vline
WA_MAINTORDCONFMS_D_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_MAINTORDCONFMS_D_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_MAINTORDCONFMS_D_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_MAINTORDCONFMS_D_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_MAINTORDCONFMS_D_STR-DRAFTENTITYOPERATIONCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.