ABAP Select data from SAP table M_TICL049 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP M_TICL049 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to M_TICL049. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the M_TICL049 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_M_TICL049 TYPE STANDARD TABLE OF M_TICL049,
      WA_M_TICL049 TYPE M_TICL049,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <M_TICL049> TYPE M_TICL049.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_M_TICL049.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM M_TICL049
  INTO TABLE IT_M_TICL049.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM M_TICL049
*  INTO TABLE @DATA(IT_M_TICL0492).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_M_TICL049 INDEX 1 INTO DATA(WA_M_TICL0492).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_M_TICL049 ASSIGNING <M_TICL049>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<M_TICL049>-CLIENT = 1.
<M_TICL049>-CLTYPE = 1.
<M_TICL049>-GENERAT = 1.
<M_TICL049>-VERSION = 1.
<M_TICL049>-SUBCLTYPE = 1.
ENDLOOP.

LOOP AT IT_M_TICL049 INTO WA_M_TICL049.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_M_TICL049-DAMAGECAT, sy-vline,
WA_M_TICL049-CLTYPEN, sy-vline,
WA_M_TICL049-CLTYPEGN, sy-vline,
WA_M_TICL049-CLTYPEVN, sy-vline,
WA_M_TICL049-SUBCLTYPEN, sy-vline,
WA_M_TICL049-DAMAGECATN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_M_TICL049 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_M_TICL049 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_M_TICL049 INTO WA_M_TICL049. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_M_TICL049_STR,
CLIENT TYPE STRING,
CLTYPE TYPE STRING,
GENERAT TYPE STRING,
VERSION TYPE STRING,
SUBCLTYPE TYPE STRING,
DAMAGECAT TYPE STRING,
CLTYPEN TYPE STRING,
CLTYPEGN TYPE STRING,
CLTYPEVN TYPE STRING,
SUBCLTYPEN TYPE STRING,
DAMAGECATN TYPE STRING,
XNEW TYPE STRING,
XNEW_RULE TYPE STRING,
NAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_M_TICL049_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_M_TICL049_STR-CLIENT sy-vline
WA_M_TICL049_STR-CLTYPE sy-vline
WA_M_TICL049_STR-GENERAT sy-vline
WA_M_TICL049_STR-VERSION sy-vline
WA_M_TICL049_STR-SUBCLTYPE sy-vline
WA_M_TICL049_STR-DAMAGECAT sy-vline
WA_M_TICL049_STR-CLTYPEN sy-vline
WA_M_TICL049_STR-CLTYPEGN sy-vline
WA_M_TICL049_STR-CLTYPEVN sy-vline
WA_M_TICL049_STR-SUBCLTYPEN sy-vline
WA_M_TICL049_STR-DAMAGECATN sy-vline
WA_M_TICL049_STR-XNEW sy-vline
WA_M_TICL049_STR-XNEW_RULE sy-vline
WA_M_TICL049_STR-NAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.