ABAP Select data from SAP table M_MCMEC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP M_MCMEC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to M_MCMEC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the M_MCMEC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_M_MCMEC TYPE STANDARD TABLE OF M_MCMEC,
      WA_M_MCMEC TYPE M_MCMEC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <M_MCMEC> TYPE M_MCMEC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_M_MCMEC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM M_MCMEC
  INTO TABLE IT_M_MCMEC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM M_MCMEC
*  INTO TABLE @DATA(IT_M_MCMEC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_M_MCMEC INDEX 1 INTO DATA(WA_M_MCMEC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_M_MCMEC ASSIGNING <M_MCMEC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<M_MCMEC>-MANDT = 1.
<M_MCMEC>-BUKRS = 1.
<M_MCMEC>-SWENR = 1.
<M_MCMEC>-SMENR = 1.
<M_MCMEC>-SGRNR = 1.
ENDLOOP.

LOOP AT IT_M_MCMEC INTO WA_M_MCMEC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_M_MCMEC-XGRTXT, sy-vline,
WA_M_MCMEC-SNUNR, sy-vline,
WA_M_MCMEC-SALTNR, sy-vline,
WA_M_MCMEC-DBEZU, sy-vline,
WA_M_MCMEC-XMETXT, sy-vline,
WA_M_MCMEC-OBJNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_M_MCMEC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_M_MCMEC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_M_MCMEC INTO WA_M_MCMEC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_M_MCMEC-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_M_MCMEC-SWENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SMENR, internal->external for field SMENR CALL FUNCTION 'CONVERSION_EXIT_SMENR_OUTPUT' EXPORTING input = WA_M_MCMEC-SMENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_M_MCMEC-SMENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SGRNR, internal->external for field SGRNR CALL FUNCTION 'CONVERSION_EXIT_SGRNR_OUTPUT' EXPORTING input = WA_M_MCMEC-SGRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_M_MCMEC-SGRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_M_MCMEC-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_M_MCMEC-IMKEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_M_MCMEC_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SMENR TYPE STRING,
SGRNR TYPE STRING,
XGRTXT TYPE STRING,
SNUNR TYPE STRING,
SALTNR TYPE STRING,
DBEZU TYPE STRING,
XMETXT TYPE STRING,
OBJNR TYPE STRING,
IMKEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_M_MCMEC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_M_MCMEC_STR-MANDT sy-vline
WA_M_MCMEC_STR-BUKRS sy-vline
WA_M_MCMEC_STR-SWENR sy-vline
WA_M_MCMEC_STR-SMENR sy-vline
WA_M_MCMEC_STR-SGRNR sy-vline
WA_M_MCMEC_STR-XGRTXT sy-vline
WA_M_MCMEC_STR-SNUNR sy-vline
WA_M_MCMEC_STR-SALTNR sy-vline
WA_M_MCMEC_STR-DBEZU sy-vline
WA_M_MCMEC_STR-XMETXT sy-vline
WA_M_MCMEC_STR-OBJNR sy-vline
WA_M_MCMEC_STR-IMKEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.