ABAP Select data from SAP table LTR2_WS_MWBGENTB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LTR2_WS_MWBGENTB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LTR2_WS_MWBGENTB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LTR2_WS_MWBGENTB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LTR2_WS_MWBGENTB TYPE STANDARD TABLE OF LTR2_WS_MWBGENTB,
      WA_LTR2_WS_MWBGENTB TYPE LTR2_WS_MWBGENTB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LTR2_WS_MWBGENTB> TYPE LTR2_WS_MWBGENTB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LTR2_WS_MWBGENTB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LTR2_WS_MWBGENTB
  INTO TABLE IT_LTR2_WS_MWBGENTB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LTR2_WS_MWBGENTB
*  INTO TABLE @DATA(IT_LTR2_WS_MWBGENTB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LTR2_WS_MWBGENTB INDEX 1 INTO DATA(WA_LTR2_WS_MWBGENTB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LTR2_WS_MWBGENTB ASSIGNING <LTR2_WS_MWBGENTB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LTR2_WS_MWBGENTB>-GUID = 1.
<LTR2_WS_MWBGENTB>-WSPOS = 1.
<LTR2_WS_MWBGENTB>-TABID = 1.
<LTR2_WS_MWBGENTB>-TABNAME = 1.
<LTR2_WS_MWBGENTB>-MWBOBJNAME = 1.
ENDLOOP.

LOOP AT IT_LTR2_WS_MWBGENTB INTO WA_LTR2_WS_MWBGENTB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LTR2_WS_MWBGENTB-MWBOBJ_SEQNO, sy-vline,
WA_LTR2_WS_MWBGENTB-READ_TYPE, sy-vline,
WA_LTR2_WS_MWBGENTB-WRT_BEHAV, sy-vline,
WA_LTR2_WS_MWBGENTB-TAB_PARALL, sy-vline,
WA_LTR2_WS_MWBGENTB-MAX_PORTION, sy-vline,
WA_LTR2_WS_MWBGENTB-TRF_DELETE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LTR2_WS_MWBGENTB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LTR2_WS_MWBGENTB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LTR2_WS_MWBGENTB INTO WA_LTR2_WS_MWBGENTB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LTR2_WS_MWBGENTB_STR,
GUID TYPE STRING,
WSPOS TYPE STRING,
TABID TYPE STRING,
TABNAME TYPE STRING,
MWBOBJNAME TYPE STRING,
MWBOBJ_SEQNO TYPE STRING,
READ_TYPE TYPE STRING,
WRT_BEHAV TYPE STRING,
TAB_PARALL TYPE STRING,
MAX_PORTION TYPE STRING,
TRF_DELETE TYPE STRING,
TRF_PRESEL_TAB TYPE STRING,
TRF_SIMULATE TYPE STRING,
MWBOBJNAME_RO TYPE STRING,
PACKAGE_SIZE TYPE STRING,
FOR_ALL_ENTRIES TYPE STRING,
MAX_IN_BLOCK TYPE STRING,
PARALLEL_HINT TYPE STRING,
GEN_U_STRUCT TYPE STRING,
SIZE_CAT TYPE STRING,
CREUSER TYPE STRING,
CREDATE TYPE STRING,
CRETIME TYPE STRING,
CHGUSER TYPE STRING,
CHGDATE TYPE STRING,
CHGTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_LTR2_WS_MWBGENTB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LTR2_WS_MWBGENTB_STR-GUID sy-vline
WA_LTR2_WS_MWBGENTB_STR-WSPOS sy-vline
WA_LTR2_WS_MWBGENTB_STR-TABID sy-vline
WA_LTR2_WS_MWBGENTB_STR-TABNAME sy-vline
WA_LTR2_WS_MWBGENTB_STR-MWBOBJNAME sy-vline
WA_LTR2_WS_MWBGENTB_STR-MWBOBJ_SEQNO sy-vline
WA_LTR2_WS_MWBGENTB_STR-READ_TYPE sy-vline
WA_LTR2_WS_MWBGENTB_STR-WRT_BEHAV sy-vline
WA_LTR2_WS_MWBGENTB_STR-TAB_PARALL sy-vline
WA_LTR2_WS_MWBGENTB_STR-MAX_PORTION sy-vline
WA_LTR2_WS_MWBGENTB_STR-TRF_DELETE sy-vline
WA_LTR2_WS_MWBGENTB_STR-TRF_PRESEL_TAB sy-vline
WA_LTR2_WS_MWBGENTB_STR-TRF_SIMULATE sy-vline
WA_LTR2_WS_MWBGENTB_STR-MWBOBJNAME_RO sy-vline
WA_LTR2_WS_MWBGENTB_STR-PACKAGE_SIZE sy-vline
WA_LTR2_WS_MWBGENTB_STR-FOR_ALL_ENTRIES sy-vline
WA_LTR2_WS_MWBGENTB_STR-MAX_IN_BLOCK sy-vline
WA_LTR2_WS_MWBGENTB_STR-PARALLEL_HINT sy-vline
WA_LTR2_WS_MWBGENTB_STR-GEN_U_STRUCT sy-vline
WA_LTR2_WS_MWBGENTB_STR-SIZE_CAT sy-vline
WA_LTR2_WS_MWBGENTB_STR-CREUSER sy-vline
WA_LTR2_WS_MWBGENTB_STR-CREDATE sy-vline
WA_LTR2_WS_MWBGENTB_STR-CRETIME sy-vline
WA_LTR2_WS_MWBGENTB_STR-CHGUSER sy-vline
WA_LTR2_WS_MWBGENTB_STR-CHGDATE sy-vline
WA_LTR2_WS_MWBGENTB_STR-CHGTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.