ABAP Select data from SAP table LTAP_CREAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LTAP_CREAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LTAP_CREAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LTAP_CREAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LTAP_CREAT TYPE STANDARD TABLE OF LTAP_CREAT,
      WA_LTAP_CREAT TYPE LTAP_CREAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LTAP_CREAT> TYPE LTAP_CREAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LTAP_CREAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LTAP_CREAT
  INTO TABLE IT_LTAP_CREAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LTAP_CREAT
*  INTO TABLE @DATA(IT_LTAP_CREAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LTAP_CREAT INDEX 1 INTO DATA(WA_LTAP_CREAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LTAP_CREAT ASSIGNING <LTAP_CREAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LTAP_CREAT>-MATNR = 1.
<LTAP_CREAT>-WERKS = 1.
<LTAP_CREAT>-LGORT = 1.
<LTAP_CREAT>-CHARG = 1.
<LTAP_CREAT>-BESTQ = 1.
ENDLOOP.

LOOP AT IT_LTAP_CREAT INTO WA_LTAP_CREAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LTAP_CREAT-SOBKZ, sy-vline,
WA_LTAP_CREAT-SONUM, sy-vline,
WA_LTAP_CREAT-LETYP, sy-vline,
WA_LTAP_CREAT-ANFME, sy-vline,
WA_LTAP_CREAT-ALTME, sy-vline,
WA_LTAP_CREAT-WDATU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LTAP_CREAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LTAP_CREAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LTAP_CREAT INTO WA_LTAP_CREAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_LTAP_CREAT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SONUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LTAP_CREAT-SONUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-SONUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LTAP_CREAT-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPDEV, internal->external for field LDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_LTAP_CREAT-LDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-LDEST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LENUM, internal->external for field VLENR CALL FUNCTION 'CONVERSION_EXIT_LENUM_OUTPUT' EXPORTING input = WA_LTAP_CREAT-VLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-VLENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LENUM, internal->external for field NLENR CALL FUNCTION 'CONVERSION_EXIT_LENUM_OUTPUT' EXPORTING input = WA_LTAP_CREAT-NLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-NLENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field /CWM/MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LTAP_CREAT-/CWM/MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-/CWM/MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field /CWM/ACT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LTAP_CREAT-/CWM/ACT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-/CWM/ACT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field /CWM/TGT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LTAP_CREAT-/CWM/TGT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LTAP_CREAT-/CWM/TGT_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LTAP_CREAT_STR,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
BESTQ TYPE STRING,
SOBKZ TYPE STRING,
SONUM TYPE STRING,
LETYP TYPE STRING,
ANFME TYPE STRING,
ALTME TYPE STRING,
WDATU TYPE STRING,
VFDAT TYPE STRING,
ZEUGN TYPE STRING,
SQUIT TYPE STRING,
NIDRU TYPE STRING,
LDEST TYPE STRING,
WEMPF TYPE STRING,
ABLAD TYPE STRING,
VLTYP TYPE STRING,
VLBER TYPE STRING,
VLPLA TYPE STRING,
VPPOS TYPE STRING,
VLENR TYPE STRING,
VLQNR TYPE STRING,
NLTYP TYPE STRING,
NLBER TYPE STRING,
NLPLA TYPE STRING,
NPPOS TYPE STRING,
NLENR TYPE STRING,
NLQNR TYPE STRING,
RLTYP TYPE STRING,
RLBER TYPE STRING,
RLPLA TYPE STRING,
RLQNR TYPE STRING,
POSNR TYPE STRING,
KBNKZ TYPE STRING,
FROM_INSP_GUID TYPE STRING,
TO_INSP_GUID TYPE STRING,
RETURN_INSP_GUID TYPE STRING,
ITAB_INDEX TYPE STRING,
SGT_SCAT TYPE STRING,
/CWM/XCWMAT TYPE STRING,
/CWM/MEINS TYPE STRING,
/CWM/ACT_QTY TYPE STRING,
/CWM/ACT_UOM TYPE STRING,
/CWM/TGT_QTY TYPE STRING,
/CWM/TGT_UOM TYPE STRING,
JCPOS TYPE STRING,END OF T_EKKO_STR. DATA: WA_LTAP_CREAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LTAP_CREAT_STR-MATNR sy-vline
WA_LTAP_CREAT_STR-WERKS sy-vline
WA_LTAP_CREAT_STR-LGORT sy-vline
WA_LTAP_CREAT_STR-CHARG sy-vline
WA_LTAP_CREAT_STR-BESTQ sy-vline
WA_LTAP_CREAT_STR-SOBKZ sy-vline
WA_LTAP_CREAT_STR-SONUM sy-vline
WA_LTAP_CREAT_STR-LETYP sy-vline
WA_LTAP_CREAT_STR-ANFME sy-vline
WA_LTAP_CREAT_STR-ALTME sy-vline
WA_LTAP_CREAT_STR-WDATU sy-vline
WA_LTAP_CREAT_STR-VFDAT sy-vline
WA_LTAP_CREAT_STR-ZEUGN sy-vline
WA_LTAP_CREAT_STR-SQUIT sy-vline
WA_LTAP_CREAT_STR-NIDRU sy-vline
WA_LTAP_CREAT_STR-LDEST sy-vline
WA_LTAP_CREAT_STR-WEMPF sy-vline
WA_LTAP_CREAT_STR-ABLAD sy-vline
WA_LTAP_CREAT_STR-VLTYP sy-vline
WA_LTAP_CREAT_STR-VLBER sy-vline
WA_LTAP_CREAT_STR-VLPLA sy-vline
WA_LTAP_CREAT_STR-VPPOS sy-vline
WA_LTAP_CREAT_STR-VLENR sy-vline
WA_LTAP_CREAT_STR-VLQNR sy-vline
WA_LTAP_CREAT_STR-NLTYP sy-vline
WA_LTAP_CREAT_STR-NLBER sy-vline
WA_LTAP_CREAT_STR-NLPLA sy-vline
WA_LTAP_CREAT_STR-NPPOS sy-vline
WA_LTAP_CREAT_STR-NLENR sy-vline
WA_LTAP_CREAT_STR-NLQNR sy-vline
WA_LTAP_CREAT_STR-RLTYP sy-vline
WA_LTAP_CREAT_STR-RLBER sy-vline
WA_LTAP_CREAT_STR-RLPLA sy-vline
WA_LTAP_CREAT_STR-RLQNR sy-vline
WA_LTAP_CREAT_STR-POSNR sy-vline
WA_LTAP_CREAT_STR-KBNKZ sy-vline
WA_LTAP_CREAT_STR-FROM_INSP_GUID sy-vline
WA_LTAP_CREAT_STR-TO_INSP_GUID sy-vline
WA_LTAP_CREAT_STR-RETURN_INSP_GUID sy-vline
WA_LTAP_CREAT_STR-ITAB_INDEX sy-vline
WA_LTAP_CREAT_STR-SGT_SCAT sy-vline
WA_LTAP_CREAT_STR-/CWM/XCWMAT sy-vline
WA_LTAP_CREAT_STR-/CWM/MEINS sy-vline
WA_LTAP_CREAT_STR-/CWM/ACT_QTY sy-vline
WA_LTAP_CREAT_STR-/CWM/ACT_UOM sy-vline
WA_LTAP_CREAT_STR-/CWM/TGT_QTY sy-vline
WA_LTAP_CREAT_STR-/CWM/TGT_UOM sy-vline
WA_LTAP_CREAT_STR-JCPOS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.