ABAP Select data from SAP table LSO_RHUMBU00_EXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LSO_RHUMBU00_EXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LSO_RHUMBU00_EXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LSO_RHUMBU00_EXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LSO_RHUMBU00_EXT TYPE STANDARD TABLE OF LSO_RHUMBU00_EXT,
      WA_LSO_RHUMBU00_EXT TYPE LSO_RHUMBU00_EXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LSO_RHUMBU00_EXT> TYPE LSO_RHUMBU00_EXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LSO_RHUMBU00_EXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LSO_RHUMBU00_EXT
  INTO TABLE IT_LSO_RHUMBU00_EXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LSO_RHUMBU00_EXT
*  INTO TABLE @DATA(IT_LSO_RHUMBU00_EXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LSO_RHUMBU00_EXT INDEX 1 INTO DATA(WA_LSO_RHUMBU00_EXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LSO_RHUMBU00_EXT ASSIGNING <LSO_RHUMBU00_EXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LSO_RHUMBU00_EXT>-PICK = 1.
<LSO_RHUMBU00_EXT>-ETTYP = 1.
<LSO_RHUMBU00_EXT>-ETYID = 1.
<LSO_RHUMBU00_EXT>-ETSHT = 1.
<LSO_RHUMBU00_EXT>-ETSTX = 1.
ENDLOOP.

LOOP AT IT_LSO_RHUMBU00_EXT INTO WA_LSO_RHUMBU00_EXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LSO_RHUMBU00_EXT-PATYP, sy-vline,
WA_LSO_RHUMBU00_EXT-PARID, sy-vline,
WA_LSO_RHUMBU00_EXT-PARSH, sy-vline,
WA_LSO_RHUMBU00_EXT-PARTX, sy-vline,
WA_LSO_RHUMBU00_EXT-ORGTY, sy-vline,
WA_LSO_RHUMBU00_EXT-ORGID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LSO_RHUMBU00_EXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LSO_RHUMBU00_EXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LSO_RHUMBU00_EXT INTO WA_LSO_RHUMBU00_EXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field EVLNG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_LSO_RHUMBU00_EXT-EVLNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LSO_RHUMBU00_EXT-EVLNG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LSO_RHUMBU00_EXT_STR,
PICK TYPE STRING,
ETTYP TYPE STRING,
ETYID TYPE STRING,
ETSHT TYPE STRING,
ETSTX TYPE STRING,
PATYP TYPE STRING,
PARID TYPE STRING,
PARSH TYPE STRING,
PARTX TYPE STRING,
ORGTY TYPE STRING,
ORGID TYPE STRING,
ORGSH TYPE STRING,
ORGTX TYPE STRING,
EVTYP TYPE STRING,
EVEID TYPE STRING,
EVSHT TYPE STRING,
EVSTX TYPE STRING,
TFORM TYPE STRING,
TXTSING TYPE STRING,
EVBEG TYPE STRING,
EVEND TYPE STRING,
MANZL TYPE STRING,
PRIOX TYPE STRING,
EVLNG TYPE STRING,
LOCKM TYPE STRING,
DELET TYPE STRING,
HISTO TYPE STRING,END OF T_EKKO_STR. DATA: WA_LSO_RHUMBU00_EXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LSO_RHUMBU00_EXT_STR-PICK sy-vline
WA_LSO_RHUMBU00_EXT_STR-ETTYP sy-vline
WA_LSO_RHUMBU00_EXT_STR-ETYID sy-vline
WA_LSO_RHUMBU00_EXT_STR-ETSHT sy-vline
WA_LSO_RHUMBU00_EXT_STR-ETSTX sy-vline
WA_LSO_RHUMBU00_EXT_STR-PATYP sy-vline
WA_LSO_RHUMBU00_EXT_STR-PARID sy-vline
WA_LSO_RHUMBU00_EXT_STR-PARSH sy-vline
WA_LSO_RHUMBU00_EXT_STR-PARTX sy-vline
WA_LSO_RHUMBU00_EXT_STR-ORGTY sy-vline
WA_LSO_RHUMBU00_EXT_STR-ORGID sy-vline
WA_LSO_RHUMBU00_EXT_STR-ORGSH sy-vline
WA_LSO_RHUMBU00_EXT_STR-ORGTX sy-vline
WA_LSO_RHUMBU00_EXT_STR-EVTYP sy-vline
WA_LSO_RHUMBU00_EXT_STR-EVEID sy-vline
WA_LSO_RHUMBU00_EXT_STR-EVSHT sy-vline
WA_LSO_RHUMBU00_EXT_STR-EVSTX sy-vline
WA_LSO_RHUMBU00_EXT_STR-TFORM sy-vline
WA_LSO_RHUMBU00_EXT_STR-TXTSING sy-vline
WA_LSO_RHUMBU00_EXT_STR-EVBEG sy-vline
WA_LSO_RHUMBU00_EXT_STR-EVEND sy-vline
WA_LSO_RHUMBU00_EXT_STR-MANZL sy-vline
WA_LSO_RHUMBU00_EXT_STR-PRIOX sy-vline
WA_LSO_RHUMBU00_EXT_STR-EVLNG sy-vline
WA_LSO_RHUMBU00_EXT_STR-LOCKM sy-vline
WA_LSO_RHUMBU00_EXT_STR-DELET sy-vline
WA_LSO_RHUMBU00_EXT_STR-HISTO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.