ABAP Select data from SAP table LSO_RHINLV10 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LSO_RHINLV10 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LSO_RHINLV10. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LSO_RHINLV10 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LSO_RHINLV10 TYPE STANDARD TABLE OF LSO_RHINLV10,
      WA_LSO_RHINLV10 TYPE LSO_RHINLV10,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LSO_RHINLV10> TYPE LSO_RHINLV10.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LSO_RHINLV10.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LSO_RHINLV10
  INTO TABLE IT_LSO_RHINLV10.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LSO_RHINLV10
*  INTO TABLE @DATA(IT_LSO_RHINLV102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LSO_RHINLV10 INDEX 1 INTO DATA(WA_LSO_RHINLV102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LSO_RHINLV10 ASSIGNING <LSO_RHINLV10>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LSO_RHINLV10>-CHECK_MARK = 1.
<LSO_RHINLV10>-ICON_STATUS = 1.
<LSO_RHINLV10>-ICON_CANCEL = 1.
<LSO_RHINLV10>-INSTY = 1.
<LSO_RHINLV10>-INSID = 1.
ENDLOOP.

LOOP AT IT_LSO_RHINLV10 INTO WA_LSO_RHINLV10.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LSO_RHINLV10-INSTX, sy-vline,
WA_LSO_RHINLV10-INSSH, sy-vline,
WA_LSO_RHINLV10-EVETX, sy-vline,
WA_LSO_RHINLV10-EVESH, sy-vline,
WA_LSO_RHINLV10-EOTYP, sy-vline,
WA_LSO_RHINLV10-EVEID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LSO_RHINLV10 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LSO_RHINLV10 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LSO_RHINLV10 INTO WA_LSO_RHINLV10. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SCOSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LSO_RHINLV10-SCOSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LSO_RHINLV10-SCOSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LSO_RHINLV10-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LSO_RHINLV10-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LSO_RHINLV10-REFDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LSO_RHINLV10-REFDOCNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LSO_RHINLV10_STR,
CHECK_MARK TYPE STRING,
ICON_STATUS TYPE STRING,
ICON_CANCEL TYPE STRING,
INSTY TYPE STRING,
INSID TYPE STRING,
INSTX TYPE STRING,
INSSH TYPE STRING,
EVETX TYPE STRING,
EVESH TYPE STRING,
EOTYP TYPE STRING,
EVEID TYPE STRING,
EVBEG TYPE STRING,
EVEND TYPE STRING,
STATUS_TRAINING TYPE STRING,
EXTRN TYPE STRING,
RTYPE TYPE STRING,
RTYID TYPE STRING,
RTYTX TYPE STRING,
RTYSH TYPE STRING,
ACTIVITYTYPE TYPE STRING,
SCOSTCENTER TYPE STRING,
ACC_ASSIGN TYPE STRING,
KOSTL TYPE STRING,
KOKRS TYPE STRING,
KKOST TYPE STRING,
KWAER TYPE STRING,
REFDOCNO TYPE STRING,
BELNR TYPE STRING,
HIDE_TYPE TYPE STRING,
TABIX TYPE STRING,END OF T_EKKO_STR. DATA: WA_LSO_RHINLV10_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LSO_RHINLV10_STR-CHECK_MARK sy-vline
WA_LSO_RHINLV10_STR-ICON_STATUS sy-vline
WA_LSO_RHINLV10_STR-ICON_CANCEL sy-vline
WA_LSO_RHINLV10_STR-INSTY sy-vline
WA_LSO_RHINLV10_STR-INSID sy-vline
WA_LSO_RHINLV10_STR-INSTX sy-vline
WA_LSO_RHINLV10_STR-INSSH sy-vline
WA_LSO_RHINLV10_STR-EVETX sy-vline
WA_LSO_RHINLV10_STR-EVESH sy-vline
WA_LSO_RHINLV10_STR-EOTYP sy-vline
WA_LSO_RHINLV10_STR-EVEID sy-vline
WA_LSO_RHINLV10_STR-EVBEG sy-vline
WA_LSO_RHINLV10_STR-EVEND sy-vline
WA_LSO_RHINLV10_STR-STATUS_TRAINING sy-vline
WA_LSO_RHINLV10_STR-EXTRN sy-vline
WA_LSO_RHINLV10_STR-RTYPE sy-vline
WA_LSO_RHINLV10_STR-RTYID sy-vline
WA_LSO_RHINLV10_STR-RTYTX sy-vline
WA_LSO_RHINLV10_STR-RTYSH sy-vline
WA_LSO_RHINLV10_STR-ACTIVITYTYPE sy-vline
WA_LSO_RHINLV10_STR-SCOSTCENTER sy-vline
WA_LSO_RHINLV10_STR-ACC_ASSIGN sy-vline
WA_LSO_RHINLV10_STR-KOSTL sy-vline
WA_LSO_RHINLV10_STR-KOKRS sy-vline
WA_LSO_RHINLV10_STR-KKOST sy-vline
WA_LSO_RHINLV10_STR-KWAER sy-vline
WA_LSO_RHINLV10_STR-REFDOCNO sy-vline
WA_LSO_RHINLV10_STR-BELNR sy-vline
WA_LSO_RHINLV10_STR-HIDE_TYPE sy-vline
WA_LSO_RHINLV10_STR-TABIX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.