ABAP Select data from SAP table LSO_CURR_ELEMENT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LSO_CURR_ELEMENT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LSO_CURR_ELEMENT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LSO_CURR_ELEMENT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LSO_CURR_ELEMENT TYPE STANDARD TABLE OF LSO_CURR_ELEMENT,
      WA_LSO_CURR_ELEMENT TYPE LSO_CURR_ELEMENT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LSO_CURR_ELEMENT> TYPE LSO_CURR_ELEMENT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LSO_CURR_ELEMENT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LSO_CURR_ELEMENT
  INTO TABLE IT_LSO_CURR_ELEMENT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LSO_CURR_ELEMENT
*  INTO TABLE @DATA(IT_LSO_CURR_ELEMENT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LSO_CURR_ELEMENT INDEX 1 INTO DATA(WA_LSO_CURR_ELEMENT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LSO_CURR_ELEMENT ASSIGNING <LSO_CURR_ELEMENT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LSO_CURR_ELEMENT>-PLANVERSION = 1.
<LSO_CURR_ELEMENT>-CURR_TYPE = 1.
<LSO_CURR_ELEMENT>-CURR_ID = 1.
<LSO_CURR_ELEMENT>-ELEM_TYPE = 1.
<LSO_CURR_ELEMENT>-ELEM_ID = 1.
ENDLOOP.

LOOP AT IT_LSO_CURR_ELEMENT INTO WA_LSO_CURR_ELEMENT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LSO_CURR_ELEMENT-ELEM_SHORT, sy-vline,
WA_LSO_CURR_ELEMENT-ELEM_STEXT, sy-vline,
WA_LSO_CURR_ELEMENT-ELEM_TFORM, sy-vline,
WA_LSO_CURR_ELEMENT-ELEM_TFTEXT, sy-vline,
WA_LSO_CURR_ELEMENT-ELEM_POSITION, sy-vline,
WA_LSO_CURR_ELEMENT-ELEM_GROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LSO_CURR_ELEMENT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LSO_CURR_ELEMENT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LSO_CURR_ELEMENT INTO WA_LSO_CURR_ELEMENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field BEF_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LSO_CURR_ELEMENT-BEF_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LSO_CURR_ELEMENT-BEF_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field AFT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LSO_CURR_ELEMENT-AFT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LSO_CURR_ELEMENT-AFT_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LSO_CURR_ELEMENT_STR,
PLANVERSION TYPE STRING,
CURR_TYPE TYPE STRING,
CURR_ID TYPE STRING,
ELEM_TYPE TYPE STRING,
ELEM_ID TYPE STRING,
ELEM_SHORT TYPE STRING,
ELEM_STEXT TYPE STRING,
ELEM_TFORM TYPE STRING,
ELEM_TFTEXT TYPE STRING,
ELEM_POSITION TYPE STRING,
ELEM_GROUP TYPE STRING,
ELEM_RATING TYPE STRING,
ELEM_DEFAULT TYPE STRING,
BEF_AMOUNT TYPE STRING,
BEF_UNIT TYPE STRING,
BEF_UNITTXT TYPE STRING,
BEF_TOJ TYPE STRING,
AFT_AMOUNT TYPE STRING,
AFT_UNIT TYPE STRING,
AFT_UNITTXT TYPE STRING,
AFT_TOJ TYPE STRING,
NUM_ORDER TYPE STRING,
NUM_ALTERN TYPE STRING,
MARK TYPE STRING,
BUT_ALTERN TYPE STRING,END OF T_EKKO_STR. DATA: WA_LSO_CURR_ELEMENT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LSO_CURR_ELEMENT_STR-PLANVERSION sy-vline
WA_LSO_CURR_ELEMENT_STR-CURR_TYPE sy-vline
WA_LSO_CURR_ELEMENT_STR-CURR_ID sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_TYPE sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_ID sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_SHORT sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_STEXT sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_TFORM sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_TFTEXT sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_POSITION sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_GROUP sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_RATING sy-vline
WA_LSO_CURR_ELEMENT_STR-ELEM_DEFAULT sy-vline
WA_LSO_CURR_ELEMENT_STR-BEF_AMOUNT sy-vline
WA_LSO_CURR_ELEMENT_STR-BEF_UNIT sy-vline
WA_LSO_CURR_ELEMENT_STR-BEF_UNITTXT sy-vline
WA_LSO_CURR_ELEMENT_STR-BEF_TOJ sy-vline
WA_LSO_CURR_ELEMENT_STR-AFT_AMOUNT sy-vline
WA_LSO_CURR_ELEMENT_STR-AFT_UNIT sy-vline
WA_LSO_CURR_ELEMENT_STR-AFT_UNITTXT sy-vline
WA_LSO_CURR_ELEMENT_STR-AFT_TOJ sy-vline
WA_LSO_CURR_ELEMENT_STR-NUM_ORDER sy-vline
WA_LSO_CURR_ELEMENT_STR-NUM_ALTERN sy-vline
WA_LSO_CURR_ELEMENT_STR-MARK sy-vline
WA_LSO_CURR_ELEMENT_STR-BUT_ALTERN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.