ABAP Select data from SAP table LSO_BO_CATALOG_ENTRY_ATTRIB_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LSO_BO_CATALOG_ENTRY_ATTRIB_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LSO_BO_CATALOG_ENTRY_ATTRIB_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LSO_BO_CATALOG_ENTRY_ATTRIB_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LSO_BO_CATALOG_ENTRY_ATTRIB_S TYPE STANDARD TABLE OF LSO_BO_CATALOG_ENTRY_ATTRIB_S,
      WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S TYPE LSO_BO_CATALOG_ENTRY_ATTRIB_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LSO_BO_CATALOG_ENTRY_ATTRIB_S> TYPE LSO_BO_CATALOG_ENTRY_ATTRIB_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LSO_BO_CATALOG_ENTRY_ATTRIB_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LSO_BO_CATALOG_ENTRY_ATTRIB_S
  INTO TABLE IT_LSO_BO_CATALOG_ENTRY_ATTRIB_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LSO_BO_CATALOG_ENTRY_ATTRIB_S
*  INTO TABLE @DATA(IT_LSO_BO_CATALOG_ENTRY_ATTRIB_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LSO_BO_CATALOG_ENTRY_ATTRIB_S INDEX 1 INTO DATA(WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LSO_BO_CATALOG_ENTRY_ATTRIB_S ASSIGNING <LSO_BO_CATALOG_ENTRY_ATTRIB_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LSO_BO_CATALOG_ENTRY_ATTRIB_S>-OBJECT_TYPE = 1.
<LSO_BO_CATALOG_ENTRY_ATTRIB_S>-OBJECT_KEY = 1.
<LSO_BO_CATALOG_ENTRY_ATTRIB_S>-PLVAR = 1.
<LSO_BO_CATALOG_ENTRY_ATTRIB_S>-OTYPE = 1.
<LSO_BO_CATALOG_ENTRY_ATTRIB_S>-OBJID = 1.
ENDLOOP.

LOOP AT IT_LSO_BO_CATALOG_ENTRY_ATTRIB_S INTO WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S-OBJECT_TYPE_TEXT, sy-vline,
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S-OBJECT_NAME, sy-vline,
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S-BEGIN_DATE, sy-vline,
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S-END_DATE, sy-vline,
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S-DELIVERYMETHOD, sy-vline,
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S-LOCATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LSO_BO_CATALOG_ENTRY_ATTRIB_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LSO_BO_CATALOG_ENTRY_ATTRIB_S INTO WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR,
OBJECT_TYPE TYPE STRING,
OBJECT_KEY TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
OBJECT_TYPE_TEXT TYPE STRING,
OBJECT_NAME TYPE STRING,
BEGIN_DATE TYPE STRING,
END_DATE TYPE STRING,
DELIVERYMETHOD TYPE STRING,
LOCATION TYPE STRING,
DURATION TYPE STRING,
SEATSAVAILABLE TYPE STRING,
STATUS TYPE STRING,
INTERNAL_PRICE TYPE STRING,
INT_CURRKEY TYPE STRING,
EXTERNAL_PRICE TYPE STRING,
EXT_CURRKEY TYPE STRING,
PORTAL_VISIBLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-OBJECT_TYPE sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-OBJECT_KEY sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-PLVAR sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-OTYPE sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-OBJID sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-OBJECT_TYPE_TEXT sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-OBJECT_NAME sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-BEGIN_DATE sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-END_DATE sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-DELIVERYMETHOD sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-LOCATION sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-DURATION sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-SEATSAVAILABLE sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-STATUS sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-INTERNAL_PRICE sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-INT_CURRKEY sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-EXTERNAL_PRICE sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-EXT_CURRKEY sy-vline
WA_LSO_BO_CATALOG_ENTRY_ATTRIB_S_STR-PORTAL_VISIBLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.