ABAP Select data from SAP table LOMD_00002048 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LOMD_00002048 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LOMD_00002048. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LOMD_00002048 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LOMD_00002048 TYPE STANDARD TABLE OF LOMD_00002048,
      WA_LOMD_00002048 TYPE LOMD_00002048,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LOMD_00002048> TYPE LOMD_00002048.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LOMD_00002048.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LOMD_00002048
  INTO TABLE IT_LOMD_00002048.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LOMD_00002048
*  INTO TABLE @DATA(IT_LOMD_000020482).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LOMD_00002048 INDEX 1 INTO DATA(WA_LOMD_000020482).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LOMD_00002048 ASSIGNING <LOMD_00002048>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LOMD_00002048>-MSGFN = 1.
<LOMD_00002048>-MEINH = 1.
<LOMD_00002048>-UMREZ = 1.
<LOMD_00002048>-UMREN = 1.
<LOMD_00002048>-EAN11 = 1.
ENDLOOP.

LOOP AT IT_LOMD_00002048 INTO WA_LOMD_00002048.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LOMD_00002048-NUMTP, sy-vline,
WA_LOMD_00002048-LAENG, sy-vline,
WA_LOMD_00002048-BREIT, sy-vline,
WA_LOMD_00002048-HOEHE, sy-vline,
WA_LOMD_00002048-MEABM, sy-vline,
WA_LOMD_00002048-VOLUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LOMD_00002048 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LOMD_00002048 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LOMD_00002048 INTO WA_LOMD_00002048. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_LOMD_00002048-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LOMD_00002048-EAN11.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LOMD_00002048_STR,
MSGFN TYPE STRING,
MEINH TYPE STRING,
UMREZ TYPE STRING,
UMREN TYPE STRING,
EAN11 TYPE STRING,
NUMTP TYPE STRING,
LAENG TYPE STRING,
BREIT TYPE STRING,
HOEHE TYPE STRING,
MEABM TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
BRGEW TYPE STRING,
GEWEI TYPE STRING,
MESUB TYPE STRING,
GTIN_VARIANT TYPE STRING,
/CWM/TY2TQ TYPE STRING,
NEST_FTR TYPE STRING,
MAX_STACK TYPE STRING,
CAPAUSE TYPE STRING,
E1MEANM TYPE STRING,END OF T_EKKO_STR. DATA: WA_LOMD_00002048_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LOMD_00002048_STR-MSGFN sy-vline
WA_LOMD_00002048_STR-MEINH sy-vline
WA_LOMD_00002048_STR-UMREZ sy-vline
WA_LOMD_00002048_STR-UMREN sy-vline
WA_LOMD_00002048_STR-EAN11 sy-vline
WA_LOMD_00002048_STR-NUMTP sy-vline
WA_LOMD_00002048_STR-LAENG sy-vline
WA_LOMD_00002048_STR-BREIT sy-vline
WA_LOMD_00002048_STR-HOEHE sy-vline
WA_LOMD_00002048_STR-MEABM sy-vline
WA_LOMD_00002048_STR-VOLUM sy-vline
WA_LOMD_00002048_STR-VOLEH sy-vline
WA_LOMD_00002048_STR-BRGEW sy-vline
WA_LOMD_00002048_STR-GEWEI sy-vline
WA_LOMD_00002048_STR-MESUB sy-vline
WA_LOMD_00002048_STR-GTIN_VARIANT sy-vline
WA_LOMD_00002048_STR-/CWM/TY2TQ sy-vline
WA_LOMD_00002048_STR-NEST_FTR sy-vline
WA_LOMD_00002048_STR-MAX_STACK sy-vline
WA_LOMD_00002048_STR-CAPAUSE sy-vline
WA_LOMD_00002048_STR-E1MEANM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.