ABAP Select data from SAP table LESHP_SHP_OBDLV_SAVE_REPLICA06 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LESHP_SHP_OBDLV_SAVE_REPLICA06 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LESHP_SHP_OBDLV_SAVE_REPLICA06. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LESHP_SHP_OBDLV_SAVE_REPLICA06 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LESHP_SHP_OBDLV_SAVE_REPLICA06 TYPE STANDARD TABLE OF LESHP_SHP_OBDLV_SAVE_REPLICA06,
      WA_LESHP_SHP_OBDLV_SAVE_REPLICA06 TYPE LESHP_SHP_OBDLV_SAVE_REPLICA06,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LESHP_SHP_OBDLV_SAVE_REPLICA06> TYPE LESHP_SHP_OBDLV_SAVE_REPLICA06.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LESHP_SHP_OBDLV_SAVE_REPLICA06.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LESHP_SHP_OBDLV_SAVE_REPLICA06
  INTO TABLE IT_LESHP_SHP_OBDLV_SAVE_REPLICA06.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LESHP_SHP_OBDLV_SAVE_REPLICA06
*  INTO TABLE @DATA(IT_LESHP_SHP_OBDLV_SAVE_REPLICA062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LESHP_SHP_OBDLV_SAVE_REPLICA06 INDEX 1 INTO DATA(WA_LESHP_SHP_OBDLV_SAVE_REPLICA062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LESHP_SHP_OBDLV_SAVE_REPLICA06 ASSIGNING <LESHP_SHP_OBDLV_SAVE_REPLICA06>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LESHP_SHP_OBDLV_SAVE_REPLICA06>-EDIDC = 1.
<LESHP_SHP_OBDLV_SAVE_REPLICA06>-MANDT = 1.
<LESHP_SHP_OBDLV_SAVE_REPLICA06>-DOCNUM = 1.
<LESHP_SHP_OBDLV_SAVE_REPLICA06>-DOCREL = 1.
<LESHP_SHP_OBDLV_SAVE_REPLICA06>-STATUS = 1.
ENDLOOP.

LOOP AT IT_LESHP_SHP_OBDLV_SAVE_REPLICA06 INTO WA_LESHP_SHP_OBDLV_SAVE_REPLICA06.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-DOCTYP, sy-vline,
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-DIRECT, sy-vline,
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVPOR, sy-vline,
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVPRT, sy-vline,
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVPRN, sy-vline,
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVSAD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LESHP_SHP_OBDLV_SAVE_REPLICA06 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LESHP_SHP_OBDLV_SAVE_REPLICA06 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LESHP_SHP_OBDLV_SAVE_REPLICA06 INTO WA_LESHP_SHP_OBDLV_SAVE_REPLICA06. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RCVPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVPRN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SNDPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-SNDPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-SNDPRN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EDIPV, internal->external for field RCVPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-RCVPFC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EDIPV, internal->external for field SNDPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-SNDPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_SHP_OBDLV_SAVE_REPLICA06-SNDPFC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR,
EDIDC TYPE STRING,
MANDT TYPE STRING,
DOCNUM TYPE STRING,
DOCREL TYPE STRING,
STATUS TYPE STRING,
DOCTYP TYPE STRING,
DIRECT TYPE STRING,
RCVPOR TYPE STRING,
RCVPRT TYPE STRING,
RCVPRN TYPE STRING,
RCVSAD TYPE STRING,
RCVSMN TYPE STRING,
RCVSNA TYPE STRING,
RCVSCA TYPE STRING,
RCVSDF TYPE STRING,
RCVSLF TYPE STRING,
RCVLAD TYPE STRING,
STD TYPE STRING,
STDVRS TYPE STRING,
STDMES TYPE STRING,
MESCOD TYPE STRING,
MESFCT TYPE STRING,
OUTMOD TYPE STRING,
TEST TYPE STRING,
SNDPOR TYPE STRING,
SNDPRT TYPE STRING,
SNDPRN TYPE STRING,
SNDSAD TYPE STRING,
SNDSMN TYPE STRING,
SNDSNA TYPE STRING,
SNDSCA TYPE STRING,
SNDSDF TYPE STRING,
SNDSLF TYPE STRING,
SNDLAD TYPE STRING,
REFINT TYPE STRING,
REFGRP TYPE STRING,
REFMES TYPE STRING,
ARCKEY TYPE STRING,
CREDAT TYPE STRING,
CRETIM TYPE STRING,
MESTYP TYPE STRING,
IDOCTP TYPE STRING,
CIMTYP TYPE STRING,
RCVPFC TYPE STRING,
SNDPFC TYPE STRING,
SERIAL TYPE STRING,
EXPRSS TYPE STRING,
UPDDAT TYPE STRING,
UPDTIM TYPE STRING,
MAXSEGNUM TYPE STRING,
E1SHP_OBDLV_SAVE_REPLICA TYPE STRING,
SENDER_SYSTEM TYPE STRING,
E1BPOBDLVHDR TYPE STRING,
DELIV_NUMB TYPE STRING,
INCOTERMS1 TYPE STRING,
INCOTERMS2 TYPE STRING,
ROUTE TYPE STRING,
SHIP_COND TYPE STRING,
TOTAL_WGHT TYPE STRING,
NET_WEIGHT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_OF_WT_ISO TYPE STRING,
VOLUME TYPE STRING,
VOLUMEUNIT TYPE STRING,
VOLUMEUNIT_ISO TYPE STRING,
NOSHPUNITS TYPE STRING,
BILLOFLADING TYPE STRING,
TRANS_CAT TYPE STRING,
TRANSP_ID TYPE STRING,
GRGISLIP_NO TYPE STRING,
EXTDELV_NO TYPE STRING,
DLV_TYPE TYPE STRING,
COMPL_DLV TYPE STRING,
DLV_BLOCK TYPE STRING,
DLV_PRIO TYPE STRING,
CUST_GROUP TYPE STRING,
PICK_LOC TYPE STRING,
TRANS_GRP TYPE STRING,
SHIP_BLOCK TYPE STRING,
ROUTESCHED TYPE STRING,
SD_DOC_CAT TYPE STRING,
PREV_DOC_NO TYPE STRING,
PREV_DOC_TYPE TYPE STRING,
SD_DOC_CAT_LONG TYPE STRING,
INCOTERMSV TYPE STRING,
INCOTERMS2L TYPE STRING,
INCOTERMS3L TYPE STRING,
RFM_PSST_GROUP TYPE STRING,
E1BPOBDLVHDRORG TYPE STRING,
DELIV_NUMB TYPE STRING,
SHIP_POINT TYPE STRING,
SALESORG TYPE STRING,
LOADING_PT TYPE STRING,
SALES_OFF TYPE STRING,
WHSE_NO TYPE STRING,
SALES_DIST TYPE STRING,
DOOR TYPE STRING,
UNLOAD_PT TYPE STRING,
E1BPDLVCONTROL TYPE STRING,
DEBUG_FLG TYPE STRING,
UPD_IND TYPE STRING,
RECV_WHS_NO TYPE STRING,
RECV_SYS TYPE STRING,
DLV_TYPE TYPE STRING,
INTERNAL_QUEUE TYPE STRING,
SERVICE_CALL TYPE STRING,
E1BPDLVPARTNER TYPE STRING,
E1BPADR1 TYPE STRING,
E1BPDLVDEADLN TYPE STRING,
E1BPOBDLVITEM TYPE STRING,
E1BPOBDLVITEMORG TYPE STRING,
E1BPDLVITEMSTTR TYPE STRING,
E1BPDLVCOBLITEM TYPE STRING,
E1BPOBDLVITEMRFO TYPE STRING,
E1BPDLVITEMRPO TYPE STRING,
E1BPDLVITMSERNO TYPE STRING,
E1BPDLVTXTHDR TYPE STRING,
E1BPDLVTXTITEM TYPE STRING,
E1BPDLVHDUNHDR TYPE STRING,
E1BPDLVHDUNITM TYPE STRING,
E1BPDLVHDUNSERNO TYPE STRING,
E1BPEXTC TYPE STRING,
E1BPEXT TYPE STRING,
E1BPTOKENREFERENCE TYPE STRING,
E1BPOBDLVITEMWMD TYPE STRING,
/CWM/E1BPOBDLVITEM TYPE STRING,
/CWM/E1BPDLVHDUNITM TYPE STRING,END OF T_EKKO_STR. DATA: WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-EDIDC sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-MANDT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DOCNUM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DOCREL sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-STATUS sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DOCTYP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DIRECT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVPOR sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVPRT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVPRN sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVSAD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVSMN sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVSNA sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVSCA sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVSDF sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVSLF sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVLAD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-STD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-STDVRS sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-STDMES sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-MESCOD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-MESFCT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-OUTMOD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-TEST sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDPOR sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDPRT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDPRN sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDSAD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDSMN sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDSNA sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDSCA sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDSDF sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDSLF sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDLAD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-REFINT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-REFGRP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-REFMES sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-ARCKEY sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-CREDAT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-CRETIM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-MESTYP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-IDOCTP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-CIMTYP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RCVPFC sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SNDPFC sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SERIAL sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-EXPRSS sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-UPDDAT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-UPDTIM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-MAXSEGNUM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1SHP_OBDLV_SAVE_REPLICA sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SENDER_SYSTEM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPOBDLVHDR sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DELIV_NUMB sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-INCOTERMS1 sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-INCOTERMS2 sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-ROUTE sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SHIP_COND sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-TOTAL_WGHT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-NET_WEIGHT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-UNIT_OF_WT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-UNIT_OF_WT_ISO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-VOLUME sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-VOLUMEUNIT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-VOLUMEUNIT_ISO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-NOSHPUNITS sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-BILLOFLADING sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-TRANS_CAT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-TRANSP_ID sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-GRGISLIP_NO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-EXTDELV_NO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DLV_TYPE sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-COMPL_DLV sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DLV_BLOCK sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DLV_PRIO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-CUST_GROUP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-PICK_LOC sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-TRANS_GRP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SHIP_BLOCK sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-ROUTESCHED sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SD_DOC_CAT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-PREV_DOC_NO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-PREV_DOC_TYPE sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SD_DOC_CAT_LONG sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-INCOTERMSV sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-INCOTERMS2L sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-INCOTERMS3L sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RFM_PSST_GROUP sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPOBDLVHDRORG sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DELIV_NUMB sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SHIP_POINT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SALESORG sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-LOADING_PT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SALES_OFF sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-WHSE_NO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SALES_DIST sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DOOR sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-UNLOAD_PT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVCONTROL sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DEBUG_FLG sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-UPD_IND sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RECV_WHS_NO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-RECV_SYS sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-DLV_TYPE sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-INTERNAL_QUEUE sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-SERVICE_CALL sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVPARTNER sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPADR1 sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVDEADLN sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPOBDLVITEM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPOBDLVITEMORG sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVITEMSTTR sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVCOBLITEM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPOBDLVITEMRFO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVITEMRPO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVITMSERNO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVTXTHDR sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVTXTITEM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVHDUNHDR sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVHDUNITM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPDLVHDUNSERNO sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPEXTC sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPEXT sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPTOKENREFERENCE sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-E1BPOBDLVITEMWMD sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-/CWM/E1BPOBDLVITEM sy-vline
WA_LESHP_SHP_OBDLV_SAVE_REPLICA06_STR-/CWM/E1BPDLVHDUNITM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.