ABAP Select data from SAP table LESHP_DELIVERY_PROC_CONTROL_IN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LESHP_DELIVERY_PROC_CONTROL_IN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LESHP_DELIVERY_PROC_CONTROL_IN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LESHP_DELIVERY_PROC_CONTROL_IN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LESHP_DELIVERY_PROC_CONTROL_IN TYPE STANDARD TABLE OF LESHP_DELIVERY_PROC_CONTROL_IN,
      WA_LESHP_DELIVERY_PROC_CONTROL_IN TYPE LESHP_DELIVERY_PROC_CONTROL_IN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LESHP_DELIVERY_PROC_CONTROL_IN> TYPE LESHP_DELIVERY_PROC_CONTROL_IN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LESHP_DELIVERY_PROC_CONTROL_IN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LESHP_DELIVERY_PROC_CONTROL_IN
  INTO TABLE IT_LESHP_DELIVERY_PROC_CONTROL_IN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LESHP_DELIVERY_PROC_CONTROL_IN
*  INTO TABLE @DATA(IT_LESHP_DELIVERY_PROC_CONTROL_IN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LESHP_DELIVERY_PROC_CONTROL_IN INDEX 1 INTO DATA(WA_LESHP_DELIVERY_PROC_CONTROL_IN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LESHP_DELIVERY_PROC_CONTROL_IN ASSIGNING <LESHP_DELIVERY_PROC_CONTROL_IN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LESHP_DELIVERY_PROC_CONTROL_IN>-DEBUG_FLG = 1.
<LESHP_DELIVERY_PROC_CONTROL_IN>-SENDER_SYSTEM = 1.
<LESHP_DELIVERY_PROC_CONTROL_IN>-PROCESS_GUID = 1.
<LESHP_DELIVERY_PROC_CONTROL_IN>-ERROR_TOLERANCE = 1.
<LESHP_DELIVERY_PROC_CONTROL_IN>-CHECK_MODE = 1.
ENDLOOP.

LOOP AT IT_LESHP_DELIVERY_PROC_CONTROL_IN INTO WA_LESHP_DELIVERY_PROC_CONTROL_IN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LESHP_DELIVERY_PROC_CONTROL_IN-IDOCNUM, sy-vline,
WA_LESHP_DELIVERY_PROC_CONTROL_IN-APOTRGUID, sy-vline,
WA_LESHP_DELIVERY_PROC_CONTROL_IN-SPE_SCENARIO_FLAG, sy-vline,
WA_LESHP_DELIVERY_PROC_CONTROL_IN-POST_ASYNC, sy-vline,
WA_LESHP_DELIVERY_PROC_CONTROL_IN-NO_BOPF_SAVE, sy-vline,
WA_LESHP_DELIVERY_PROC_CONTROL_IN-REPEAT_BLOCKED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LESHP_DELIVERY_PROC_CONTROL_IN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LESHP_DELIVERY_PROC_CONTROL_IN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LESHP_DELIVERY_PROC_CONTROL_IN INTO WA_LESHP_DELIVERY_PROC_CONTROL_IN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SENDER_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LESHP_DELIVERY_PROC_CONTROL_IN-SENDER_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_DELIVERY_PROC_CONTROL_IN-SENDER_SYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SPE_OUTB_CRIT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LESHP_DELIVERY_PROC_CONTROL_IN-SPE_OUTB_CRIT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_DELIVERY_PROC_CONTROL_IN-SPE_OUTB_CRIT_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LESHP_DELIVERY_PROC_CONTROL_IN_STR,
DEBUG_FLG TYPE STRING,
SENDER_SYSTEM TYPE STRING,
PROCESS_GUID TYPE STRING,
ERROR_TOLERANCE TYPE STRING,
CHECK_MODE TYPE STRING,
IDOCNUM TYPE STRING,
APOTRGUID TYPE STRING,
SPE_SCENARIO_FLAG TYPE STRING,
POST_ASYNC TYPE STRING,
NO_BOPF_SAVE TYPE STRING,
REPEAT_BLOCKED TYPE STRING,
MAX_LINES TYPE STRING,
MAX_TASKS TYPE STRING,
NO_MES_UPD TYPE STRING,
SEL_ITEM_ONLY TYPE STRING,
PACKAGE_TYPE TYPE STRING,
LEDAT_HIGH_MAX TYPE STRING,
RFC_GROUP TYPE STRING,
NO_COMMIT TYPE STRING,
NO_INIT TYPE STRING,
NO_SAVE TYPE STRING,
NO_RENUMBER TYPE STRING,
NO_ENQUEUE TYPE STRING,
SYNCHRON TYPE STRING,
SPLITPROT_REQUESTED TYPE STRING,
SPE_INITIATOR_PROCESS TYPE STRING,
SPE_OUTB_CRIT_LIMIT TYPE STRING,
SPE_OUTB_CRIT_UNIT TYPE STRING,
SPE_OUTB_NOROUTE_CALC TYPE STRING,
SPE_OUTB_ATP_TMSTMP_GIVEN TYPE STRING,
SPE_OUTB_NO_RLDAT_CHECK TYPE STRING,
SPE_OUTB_GEOROUTE_ACTIVE TYPE STRING,
SPE_MAX_NR_DELIVERIES TYPE STRING,
SPE_CR_TMPID TYPE STRING,
PROCESS_HOLD_HEADER TYPE STRING,
SPE_DIST_PROC_CODE TYPE STRING,
SPE_AUTO_GR TYPE STRING,
MAX_NUMBER_DELIVERIES TYPE STRING,
SPE_AUTO_DLV TYPE STRING,
SPE_ADD_ITEMS TYPE STRING,
NO_BUFFER_REFRESH TYPE STRING,
NO_RMSYS_DLV_CHG TYPE STRING,
LE_TM_INTEGRATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-DEBUG_FLG sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SENDER_SYSTEM sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-PROCESS_GUID sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-ERROR_TOLERANCE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-CHECK_MODE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-IDOCNUM sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-APOTRGUID sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_SCENARIO_FLAG sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-POST_ASYNC sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_BOPF_SAVE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-REPEAT_BLOCKED sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-MAX_LINES sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-MAX_TASKS sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_MES_UPD sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SEL_ITEM_ONLY sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-PACKAGE_TYPE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-LEDAT_HIGH_MAX sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-RFC_GROUP sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_COMMIT sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_INIT sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_SAVE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_RENUMBER sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_ENQUEUE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SYNCHRON sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPLITPROT_REQUESTED sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_INITIATOR_PROCESS sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_OUTB_CRIT_LIMIT sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_OUTB_CRIT_UNIT sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_OUTB_NOROUTE_CALC sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_OUTB_ATP_TMSTMP_GIVEN sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_OUTB_NO_RLDAT_CHECK sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_OUTB_GEOROUTE_ACTIVE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_MAX_NR_DELIVERIES sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_CR_TMPID sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-PROCESS_HOLD_HEADER sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_DIST_PROC_CODE sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_AUTO_GR sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-MAX_NUMBER_DELIVERIES sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_AUTO_DLV sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-SPE_ADD_ITEMS sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_BUFFER_REFRESH sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-NO_RMSYS_DLV_CHG sy-vline
WA_LESHP_DELIVERY_PROC_CONTROL_IN_STR-LE_TM_INTEGRATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.