ABAP Select data from SAP table LESHP_00002642 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LESHP_00002642 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LESHP_00002642. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LESHP_00002642 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LESHP_00002642 TYPE STANDARD TABLE OF LESHP_00002642,
      WA_LESHP_00002642 TYPE LESHP_00002642,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LESHP_00002642> TYPE LESHP_00002642.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LESHP_00002642.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LESHP_00002642
  INTO TABLE IT_LESHP_00002642.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LESHP_00002642
*  INTO TABLE @DATA(IT_LESHP_000026422).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LESHP_00002642 INDEX 1 INTO DATA(WA_LESHP_000026422).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LESHP_00002642 ASSIGNING <LESHP_00002642>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LESHP_00002642>-PACKAGE_CAT = 1.
<LESHP_00002642>-TRANSP_INDEX = 1.
<LESHP_00002642>-CRIT_SAF_INDEX = 1.
<LESHP_00002642>-FLG_DG_PACKAGE = 1.
<LESHP_00002642>-DG_PACKAGE_LEVEL = 1.
ENDLOOP.

LOOP AT IT_LESHP_00002642 INTO WA_LESHP_00002642.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LESHP_00002642-PACKCODE, sy-vline,
WA_LESHP_00002642-INSTR_ENCL_CAT, sy-vline,
WA_LESHP_00002642-MAT_DAMAGED_CL7, sy-vline,
WA_LESHP_00002642-DOSE_RATE_BULK, sy-vline,
WA_LESHP_00002642-DOSE_RATE_BULK_U, sy-vline,
WA_LESHP_00002642-DOSE_RATE_PACK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LESHP_00002642 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LESHP_00002642 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LESHP_00002642 INTO WA_LESHP_00002642. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LESHP_00002642_STR,
PACKAGE_CAT TYPE STRING,
TRANSP_INDEX TYPE STRING,
CRIT_SAF_INDEX TYPE STRING,
FLG_DG_PACKAGE TYPE STRING,
DG_PACKAGE_LEVEL TYPE STRING,
PACKCODE TYPE STRING,
INSTR_ENCL_CAT TYPE STRING,
MAT_DAMAGED_CL7 TYPE STRING,
DOSE_RATE_BULK TYPE STRING,
DOSE_RATE_BULK_U TYPE STRING,
DOSE_RATE_PACK TYPE STRING,
U_DOSE_RATE_PACK TYPE STRING,
LEADING_LWDG TYPE STRING,
MAX_GROSS_WEIGHT TYPE STRING,
U_MAX_GROSS_WGHT TYPE STRING,
E1EDD51 TYPE STRING,END OF T_EKKO_STR. DATA: WA_LESHP_00002642_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LESHP_00002642_STR-PACKAGE_CAT sy-vline
WA_LESHP_00002642_STR-TRANSP_INDEX sy-vline
WA_LESHP_00002642_STR-CRIT_SAF_INDEX sy-vline
WA_LESHP_00002642_STR-FLG_DG_PACKAGE sy-vline
WA_LESHP_00002642_STR-DG_PACKAGE_LEVEL sy-vline
WA_LESHP_00002642_STR-PACKCODE sy-vline
WA_LESHP_00002642_STR-INSTR_ENCL_CAT sy-vline
WA_LESHP_00002642_STR-MAT_DAMAGED_CL7 sy-vline
WA_LESHP_00002642_STR-DOSE_RATE_BULK sy-vline
WA_LESHP_00002642_STR-DOSE_RATE_BULK_U sy-vline
WA_LESHP_00002642_STR-DOSE_RATE_PACK sy-vline
WA_LESHP_00002642_STR-U_DOSE_RATE_PACK sy-vline
WA_LESHP_00002642_STR-LEADING_LWDG sy-vline
WA_LESHP_00002642_STR-MAX_GROSS_WEIGHT sy-vline
WA_LESHP_00002642_STR-U_MAX_GROSS_WGHT sy-vline
WA_LESHP_00002642_STR-E1EDD51 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.