ABAP Select data from SAP table LESHP_00002386 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LESHP_00002386 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LESHP_00002386. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LESHP_00002386 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LESHP_00002386 TYPE STANDARD TABLE OF LESHP_00002386,
      WA_LESHP_00002386 TYPE LESHP_00002386,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LESHP_00002386> TYPE LESHP_00002386.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LESHP_00002386.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LESHP_00002386
  INTO TABLE IT_LESHP_00002386.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LESHP_00002386
*  INTO TABLE @DATA(IT_LESHP_000023862).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LESHP_00002386 INDEX 1 INTO DATA(WA_LESHP_000023862).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LESHP_00002386 ASSIGNING <LESHP_00002386>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LESHP_00002386>-VBELN_VL = 1.
<LESHP_00002386>-POSNR_VL = 1.
<LESHP_00002386>-VBELN = 1.
<LESHP_00002386>-POSNN = 1.
<LESHP_00002386>-VBTYP_N = 1.
ENDLOOP.

LOOP AT IT_LESHP_00002386 INTO WA_LESHP_00002386.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LESHP_00002386-PIKMG, sy-vline,
WA_LESHP_00002386-MEINS, sy-vline,
WA_LESHP_00002386-NDIFM, sy-vline,
WA_LESHP_00002386-TAQUI, sy-vline,
WA_LESHP_00002386-BRGEW, sy-vline,
WA_LESHP_00002386-NTGEW, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LESHP_00002386 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LESHP_00002386 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LESHP_00002386 INTO WA_LESHP_00002386. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN_VL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LESHP_00002386-VBELN_VL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_00002386-VBELN_VL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LESHP_00002386-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LESHP_00002386-VBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LESHP_00002386_STR,
VBELN_VL TYPE STRING,
POSNR_VL TYPE STRING,
VBELN TYPE STRING,
POSNN TYPE STRING,
VBTYP_N TYPE STRING,
PIKMG TYPE STRING,
MEINS TYPE STRING,
NDIFM TYPE STRING,
TAQUI TYPE STRING,
BRGEW TYPE STRING,
NTGEW TYPE STRING,
GEWEI TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
CHARG TYPE STRING,
MATNR TYPE STRING,
ORPOS TYPE STRING,
MATNR_EXTERNAL TYPE STRING,
MATNR_VERSION TYPE STRING,
MATNR_GUID TYPE STRING,
MATNR_LONG TYPE STRING,
VBTYP_N_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_LESHP_00002386_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LESHP_00002386_STR-VBELN_VL sy-vline
WA_LESHP_00002386_STR-POSNR_VL sy-vline
WA_LESHP_00002386_STR-VBELN sy-vline
WA_LESHP_00002386_STR-POSNN sy-vline
WA_LESHP_00002386_STR-VBTYP_N sy-vline
WA_LESHP_00002386_STR-PIKMG sy-vline
WA_LESHP_00002386_STR-MEINS sy-vline
WA_LESHP_00002386_STR-NDIFM sy-vline
WA_LESHP_00002386_STR-TAQUI sy-vline
WA_LESHP_00002386_STR-BRGEW sy-vline
WA_LESHP_00002386_STR-NTGEW sy-vline
WA_LESHP_00002386_STR-GEWEI sy-vline
WA_LESHP_00002386_STR-VOLUM sy-vline
WA_LESHP_00002386_STR-VOLEH sy-vline
WA_LESHP_00002386_STR-CHARG sy-vline
WA_LESHP_00002386_STR-MATNR sy-vline
WA_LESHP_00002386_STR-ORPOS sy-vline
WA_LESHP_00002386_STR-MATNR_EXTERNAL sy-vline
WA_LESHP_00002386_STR-MATNR_VERSION sy-vline
WA_LESHP_00002386_STR-MATNR_GUID sy-vline
WA_LESHP_00002386_STR-MATNR_LONG sy-vline
WA_LESHP_00002386_STR-VBTYP_N_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.