ABAP Select data from SAP table LEINT_SHRDFLD_HU into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LEINT_SHRDFLD_HU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LEINT_SHRDFLD_HU. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LEINT_SHRDFLD_HU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LEINT_SHRDFLD_HU TYPE STANDARD TABLE OF LEINT_SHRDFLD_HU,
      WA_LEINT_SHRDFLD_HU TYPE LEINT_SHRDFLD_HU,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LEINT_SHRDFLD_HU> TYPE LEINT_SHRDFLD_HU.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LEINT_SHRDFLD_HU.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LEINT_SHRDFLD_HU
  INTO TABLE IT_LEINT_SHRDFLD_HU.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LEINT_SHRDFLD_HU
*  INTO TABLE @DATA(IT_LEINT_SHRDFLD_HU2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LEINT_SHRDFLD_HU INDEX 1 INTO DATA(WA_LEINT_SHRDFLD_HU2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LEINT_SHRDFLD_HU ASSIGNING <LEINT_SHRDFLD_HU>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LEINT_SHRDFLD_HU>-EXIDV = 1.
<LEINT_SHRDFLD_HU>-EXIDV2 = 1.
<LEINT_SHRDFLD_HU>-SIGNI = 1.
<LEINT_SHRDFLD_HU>-NAMEF = 1.
<LEINT_SHRDFLD_HU>-LANDF = 1.
ENDLOOP.

LOOP AT IT_LEINT_SHRDFLD_HU INTO WA_LEINT_SHRDFLD_HU.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LEINT_SHRDFLD_HU-NAMBE, sy-vline,
WA_LEINT_SHRDFLD_HU-OWNER, sy-vline,
WA_LEINT_SHRDFLD_HU-FWAGN, sy-vline,
WA_LEINT_SHRDFLD_HU-TRNPD, sy-vline,
WA_LEINT_SHRDFLD_HU-VHILM, sy-vline,
WA_LEINT_SHRDFLD_HU-VHART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LEINT_SHRDFLD_HU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LEINT_SHRDFLD_HU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LEINT_SHRDFLD_HU INTO WA_LEINT_SHRDFLD_HU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EXIDV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-EXIDV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-EXIDV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FWAGN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-FWAGN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-FWAGN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field VHILM CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-VHILM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-VHILM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSHME, internal->external for field SCSTM CALL FUNCTION 'CONVERSION_EXIT_TSHME_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-SCSTM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-SCSTM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSHME, internal->external for field SCETM CALL FUNCTION 'CONVERSION_EXIT_TSHME_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-SCETM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-SCETM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSHME, internal->external for field ATMSFSCH CALL FUNCTION 'CONVERSION_EXIT_TSHME_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-ATMSFSCH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-ATMSFSCH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSHME, internal->external for field ATMSTSCH CALL FUNCTION 'CONVERSION_EXIT_TSHME_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-ATMSTSCH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-ATMSTSCH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSHME, internal->external for field ATMSF CALL FUNCTION 'CONVERSION_EXIT_TSHME_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-ATMSF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-ATMSF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSHME, internal->external for field ATMST CALL FUNCTION 'CONVERSION_EXIT_TSHME_OUTPUT' EXPORTING input = WA_LEINT_SHRDFLD_HU-ATMST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LEINT_SHRDFLD_HU-ATMST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LEINT_SHRDFLD_HU_STR,
EXIDV TYPE STRING,
EXIDV2 TYPE STRING,
SIGNI TYPE STRING,
NAMEF TYPE STRING,
LANDF TYPE STRING,
NAMBE TYPE STRING,
OWNER TYPE STRING,
FWAGN TYPE STRING,
TRNPD TYPE STRING,
VHILM TYPE STRING,
VHART TYPE STRING,
VELTP TYPE STRING,
PRRTY TYPE STRING,
STATS TYPE STRING,
LYARD TYPE STRING,
YLCCL TYPE STRING,
YLOCT TYPE STRING,
BLIND TYPE STRING,
RSNCD TYPE STRING,
SCACD TYPE STRING,
PRFLG TYPE STRING,
SLFLG TYPE STRING,
LTEXT TYPE STRING,
YSTATS TYPE STRING,
SCHFL TYPE STRING,
SCLCL TYPE STRING,
SCLOC TYPE STRING,
SCSTM TYPE STRING,
SCETM TYPE STRING,
ATMSFSCH TYPE STRING,
ATMSTSCH TYPE STRING,
TMIYD TYPE STRING,
ATMSF TYPE STRING,
ATMST TYPE STRING,END OF T_EKKO_STR. DATA: WA_LEINT_SHRDFLD_HU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LEINT_SHRDFLD_HU_STR-EXIDV sy-vline
WA_LEINT_SHRDFLD_HU_STR-EXIDV2 sy-vline
WA_LEINT_SHRDFLD_HU_STR-SIGNI sy-vline
WA_LEINT_SHRDFLD_HU_STR-NAMEF sy-vline
WA_LEINT_SHRDFLD_HU_STR-LANDF sy-vline
WA_LEINT_SHRDFLD_HU_STR-NAMBE sy-vline
WA_LEINT_SHRDFLD_HU_STR-OWNER sy-vline
WA_LEINT_SHRDFLD_HU_STR-FWAGN sy-vline
WA_LEINT_SHRDFLD_HU_STR-TRNPD sy-vline
WA_LEINT_SHRDFLD_HU_STR-VHILM sy-vline
WA_LEINT_SHRDFLD_HU_STR-VHART sy-vline
WA_LEINT_SHRDFLD_HU_STR-VELTP sy-vline
WA_LEINT_SHRDFLD_HU_STR-PRRTY sy-vline
WA_LEINT_SHRDFLD_HU_STR-STATS sy-vline
WA_LEINT_SHRDFLD_HU_STR-LYARD sy-vline
WA_LEINT_SHRDFLD_HU_STR-YLCCL sy-vline
WA_LEINT_SHRDFLD_HU_STR-YLOCT sy-vline
WA_LEINT_SHRDFLD_HU_STR-BLIND sy-vline
WA_LEINT_SHRDFLD_HU_STR-RSNCD sy-vline
WA_LEINT_SHRDFLD_HU_STR-SCACD sy-vline
WA_LEINT_SHRDFLD_HU_STR-PRFLG sy-vline
WA_LEINT_SHRDFLD_HU_STR-SLFLG sy-vline
WA_LEINT_SHRDFLD_HU_STR-LTEXT sy-vline
WA_LEINT_SHRDFLD_HU_STR-YSTATS sy-vline
WA_LEINT_SHRDFLD_HU_STR-SCHFL sy-vline
WA_LEINT_SHRDFLD_HU_STR-SCLCL sy-vline
WA_LEINT_SHRDFLD_HU_STR-SCLOC sy-vline
WA_LEINT_SHRDFLD_HU_STR-SCSTM sy-vline
WA_LEINT_SHRDFLD_HU_STR-SCETM sy-vline
WA_LEINT_SHRDFLD_HU_STR-ATMSFSCH sy-vline
WA_LEINT_SHRDFLD_HU_STR-ATMSTSCH sy-vline
WA_LEINT_SHRDFLD_HU_STR-TMIYD sy-vline
WA_LEINT_SHRDFLD_HU_STR-ATMSF sy-vline
WA_LEINT_SHRDFLD_HU_STR-ATMST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.