ABAP Select data from SAP table LECI_OVERVIEW_DYN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LECI_OVERVIEW_DYN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LECI_OVERVIEW_DYN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LECI_OVERVIEW_DYN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LECI_OVERVIEW_DYN TYPE STANDARD TABLE OF LECI_OVERVIEW_DYN,
      WA_LECI_OVERVIEW_DYN TYPE LECI_OVERVIEW_DYN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LECI_OVERVIEW_DYN> TYPE LECI_OVERVIEW_DYN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LECI_OVERVIEW_DYN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LECI_OVERVIEW_DYN
  INTO TABLE IT_LECI_OVERVIEW_DYN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LECI_OVERVIEW_DYN
*  INTO TABLE @DATA(IT_LECI_OVERVIEW_DYN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LECI_OVERVIEW_DYN INDEX 1 INTO DATA(WA_LECI_OVERVIEW_DYN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LECI_OVERVIEW_DYN ASSIGNING <LECI_OVERVIEW_DYN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LECI_OVERVIEW_DYN>-PASS_NUMB = 1.
<LECI_OVERVIEW_DYN>-PASS_DATE = 1.
<LECI_OVERVIEW_DYN>-PASS_TIME = 1.
<LECI_OVERVIEW_DYN>-LEAVE_DATE = 1.
<LECI_OVERVIEW_DYN>-LEAVE_TIME = 1.
ENDLOOP.

LOOP AT IT_LECI_OVERVIEW_DYN INTO WA_LECI_OVERVIEW_DYN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LECI_OVERVIEW_DYN-ICON_CHKI_TYPE, sy-vline,
WA_LECI_OVERVIEW_DYN-ICON_CHKI_EVENT, sy-vline,
WA_LECI_OVERVIEW_DYN-VEHICLE_REG_NUMB, sy-vline,
WA_LECI_OVERVIEW_DYN-TRAILER_REG_NUMB, sy-vline,
WA_LECI_OVERVIEW_DYN-CONT_REG_NUMB1, sy-vline,
WA_LECI_OVERVIEW_DYN-CONT_REG_NUMB2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LECI_OVERVIEW_DYN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LECI_OVERVIEW_DYN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LECI_OVERVIEW_DYN INTO WA_LECI_OVERVIEW_DYN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PASS_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LECI_OVERVIEW_DYN-PASS_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LECI_OVERVIEW_DYN-PASS_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VEHICLE_REG_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LECI_OVERVIEW_DYN-VEHICLE_REG_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LECI_OVERVIEW_DYN-VEHICLE_REG_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRAILER_REG_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LECI_OVERVIEW_DYN-TRAILER_REG_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LECI_OVERVIEW_DYN-TRAILER_REG_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONT_REG_NUMB1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LECI_OVERVIEW_DYN-CONT_REG_NUMB1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LECI_OVERVIEW_DYN-CONT_REG_NUMB1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONT_REG_NUMB2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_LECI_OVERVIEW_DYN-CONT_REG_NUMB2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LECI_OVERVIEW_DYN-CONT_REG_NUMB2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field NAME_CONTACT CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_LECI_OVERVIEW_DYN-NAME_CONTACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LECI_OVERVIEW_DYN-NAME_CONTACT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LECI_OVERVIEW_DYN_STR,
PASS_NUMB TYPE STRING,
PASS_DATE TYPE STRING,
PASS_TIME TYPE STRING,
LEAVE_DATE TYPE STRING,
LEAVE_TIME TYPE STRING,
ICON_CHKI_TYPE TYPE STRING,
ICON_CHKI_EVENT TYPE STRING,
VEHICLE_REG_NUMB TYPE STRING,
TRAILER_REG_NUMB TYPE STRING,
CONT_REG_NUMB1 TYPE STRING,
CONT_REG_NUMB2 TYPE STRING,
CIOV_NAME TYPE STRING,
NAT_DRVR TYPE STRING,
NAME_CODRVR TYPE STRING,
VEND_TXT TYPE STRING,
COMPANY TYPE STRING,
CARGO_TXT TYPE STRING,
PARKING_TXT TYPE STRING,
STAGING_AREA TYPE STRING,
SHP_POINT TYPE STRING,
WHS_NUMB TYPE STRING,
WHS_GATE TYPE STRING,
NAME_CONTACT TYPE STRING,
BUILDING TYPE STRING,
PHONE TYPE STRING,
CHK_PT_IN_TXT TYPE STRING,
TAKER_IN TYPE STRING,
CHK_PT_OUT_TXT TYPE STRING,
TAKER_OUT TYPE STRING,END OF T_EKKO_STR. DATA: WA_LECI_OVERVIEW_DYN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LECI_OVERVIEW_DYN_STR-PASS_NUMB sy-vline
WA_LECI_OVERVIEW_DYN_STR-PASS_DATE sy-vline
WA_LECI_OVERVIEW_DYN_STR-PASS_TIME sy-vline
WA_LECI_OVERVIEW_DYN_STR-LEAVE_DATE sy-vline
WA_LECI_OVERVIEW_DYN_STR-LEAVE_TIME sy-vline
WA_LECI_OVERVIEW_DYN_STR-ICON_CHKI_TYPE sy-vline
WA_LECI_OVERVIEW_DYN_STR-ICON_CHKI_EVENT sy-vline
WA_LECI_OVERVIEW_DYN_STR-VEHICLE_REG_NUMB sy-vline
WA_LECI_OVERVIEW_DYN_STR-TRAILER_REG_NUMB sy-vline
WA_LECI_OVERVIEW_DYN_STR-CONT_REG_NUMB1 sy-vline
WA_LECI_OVERVIEW_DYN_STR-CONT_REG_NUMB2 sy-vline
WA_LECI_OVERVIEW_DYN_STR-CIOV_NAME sy-vline
WA_LECI_OVERVIEW_DYN_STR-NAT_DRVR sy-vline
WA_LECI_OVERVIEW_DYN_STR-NAME_CODRVR sy-vline
WA_LECI_OVERVIEW_DYN_STR-VEND_TXT sy-vline
WA_LECI_OVERVIEW_DYN_STR-COMPANY sy-vline
WA_LECI_OVERVIEW_DYN_STR-CARGO_TXT sy-vline
WA_LECI_OVERVIEW_DYN_STR-PARKING_TXT sy-vline
WA_LECI_OVERVIEW_DYN_STR-STAGING_AREA sy-vline
WA_LECI_OVERVIEW_DYN_STR-SHP_POINT sy-vline
WA_LECI_OVERVIEW_DYN_STR-WHS_NUMB sy-vline
WA_LECI_OVERVIEW_DYN_STR-WHS_GATE sy-vline
WA_LECI_OVERVIEW_DYN_STR-NAME_CONTACT sy-vline
WA_LECI_OVERVIEW_DYN_STR-BUILDING sy-vline
WA_LECI_OVERVIEW_DYN_STR-PHONE sy-vline
WA_LECI_OVERVIEW_DYN_STR-CHK_PT_IN_TXT sy-vline
WA_LECI_OVERVIEW_DYN_STR-TAKER_IN sy-vline
WA_LECI_OVERVIEW_DYN_STR-CHK_PT_OUT_TXT sy-vline
WA_LECI_OVERVIEW_DYN_STR-TAKER_OUT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.