ABAP Select data from SAP table LCA_WARNINGS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LCA_WARNINGS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LCA_WARNINGS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LCA_WARNINGS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LCA_WARNINGS TYPE STANDARD TABLE OF LCA_WARNINGS,
      WA_LCA_WARNINGS TYPE LCA_WARNINGS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LCA_WARNINGS> TYPE LCA_WARNINGS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LCA_WARNINGS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LCA_WARNINGS
  INTO TABLE IT_LCA_WARNINGS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LCA_WARNINGS
*  INTO TABLE @DATA(IT_LCA_WARNINGS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LCA_WARNINGS INDEX 1 INTO DATA(WA_LCA_WARNINGS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LCA_WARNINGS ASSIGNING <LCA_WARNINGS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LCA_WARNINGS>-PRIORITY = 1.
<LCA_WARNINGS>-MSG_NO = 1.
<LCA_WARNINGS>-LINE_NO = 1.
<LCA_WARNINGS>-WARN_CODE = 1.
<LCA_WARNINGS>-CREATION_TIME = 1.
ENDLOOP.

LOOP AT IT_LCA_WARNINGS INTO WA_LCA_WARNINGS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LCA_WARNINGS-CLIENT, sy-vline,
WA_LCA_WARNINGS-TRANSACT, sy-vline,
WA_LCA_WARNINGS-REPORT, sy-vline,
WA_LCA_WARNINGS-UNAME, sy-vline,
WA_LCA_WARNINGS-LCA_ROUTINE, sy-vline,
WA_LCA_WARNINGS-PLANVERSION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LCA_WARNINGS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LCA_WARNINGS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LCA_WARNINGS INTO WA_LCA_WARNINGS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field CREATION_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_LCA_WARNINGS-CREATION_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LCA_WARNINGS-CREATION_TIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LCA_WARNINGS_STR,
PRIORITY TYPE STRING,
MSG_NO TYPE STRING,
LINE_NO TYPE STRING,
WARN_CODE TYPE STRING,
CREATION_TIME TYPE STRING,
CLIENT TYPE STRING,
TRANSACT TYPE STRING,
REPORT TYPE STRING,
UNAME TYPE STRING,
LCA_ROUTINE TYPE STRING,
PLANVERSION TYPE STRING,
SIMSESSION TYPE STRING,
BATCH TYPE STRING,
MESSAGE TYPE STRING,END OF T_EKKO_STR. DATA: WA_LCA_WARNINGS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LCA_WARNINGS_STR-PRIORITY sy-vline
WA_LCA_WARNINGS_STR-MSG_NO sy-vline
WA_LCA_WARNINGS_STR-LINE_NO sy-vline
WA_LCA_WARNINGS_STR-WARN_CODE sy-vline
WA_LCA_WARNINGS_STR-CREATION_TIME sy-vline
WA_LCA_WARNINGS_STR-CLIENT sy-vline
WA_LCA_WARNINGS_STR-TRANSACT sy-vline
WA_LCA_WARNINGS_STR-REPORT sy-vline
WA_LCA_WARNINGS_STR-UNAME sy-vline
WA_LCA_WARNINGS_STR-LCA_ROUTINE sy-vline
WA_LCA_WARNINGS_STR-PLANVERSION sy-vline
WA_LCA_WARNINGS_STR-SIMSESSION sy-vline
WA_LCA_WARNINGS_STR-BATCH sy-vline
WA_LCA_WARNINGS_STR-MESSAGE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.