ABAP Select data from SAP table KWH_BG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP KWH_BG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to KWH_BG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the KWH_BG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_KWH_BG TYPE STANDARD TABLE OF KWH_BG,
      WA_KWH_BG TYPE KWH_BG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <KWH_BG> TYPE KWH_BG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_KWH_BG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM KWH_BG
  INTO TABLE IT_KWH_BG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM KWH_BG
*  INTO TABLE @DATA(IT_KWH_BG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_KWH_BG INDEX 1 INTO DATA(WA_KWH_BG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_KWH_BG ASSIGNING <KWH_BG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<KWH_BG>-JOBNAME = 1.
<KWH_BG>-JOBCOUNT = 1.
<KWH_BG>-PROGNAME = 1.
<KWH_BG>-SDLDATE = 1.
<KWH_BG>-SDLTIME = 1.
ENDLOOP.

LOOP AT IT_KWH_BG INTO WA_KWH_BG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_KWH_BG-SDLUNAME, sy-vline,
WA_KWH_BG-LISTIDENT, sy-vline,
WA_KWH_BG-DESCRIPTION, sy-vline,
ENDLOOP. *Add any further fields from structure WA_KWH_BG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_KWH_BG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_KWH_BG INTO WA_KWH_BG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_KWH_BG_STR,
JOBNAME TYPE STRING,
JOBCOUNT TYPE STRING,
PROGNAME TYPE STRING,
SDLDATE TYPE STRING,
SDLTIME TYPE STRING,
SDLUNAME TYPE STRING,
LISTIDENT TYPE STRING,
DESCRIPTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_KWH_BG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_KWH_BG_STR-JOBNAME sy-vline
WA_KWH_BG_STR-JOBCOUNT sy-vline
WA_KWH_BG_STR-PROGNAME sy-vline
WA_KWH_BG_STR-SDLDATE sy-vline
WA_KWH_BG_STR-SDLTIME sy-vline
WA_KWH_BG_STR-SDLUNAME sy-vline
WA_KWH_BG_STR-LISTIDENT sy-vline
WA_KWH_BG_STR-DESCRIPTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.