ABAP Select data from SAP table KOMFKZM_WW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP KOMFKZM_WW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to KOMFKZM_WW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the KOMFKZM_WW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_KOMFKZM_WW TYPE STANDARD TABLE OF KOMFKZM_WW,
      WA_KOMFKZM_WW TYPE KOMFKZM_WW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <KOMFKZM_WW> TYPE KOMFKZM_WW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_KOMFKZM_WW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM KOMFKZM_WW
  INTO TABLE IT_KOMFKZM_WW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM KOMFKZM_WW
*  INTO TABLE @DATA(IT_KOMFKZM_WW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_KOMFKZM_WW INDEX 1 INTO DATA(WA_KOMFKZM_WW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_KOMFKZM_WW ASSIGNING <KOMFKZM_WW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<KOMFKZM_WW>-TYPZM = 1.
<KOMFKZM_WW>-CCINS = 1.
<KOMFKZM_WW>-CCNUM = 1.
<KOMFKZM_WW>-CCFOL = 1.
<KOMFKZM_WW>-DATAB = 1.
ENDLOOP.

LOOP AT IT_KOMFKZM_WW INTO WA_KOMFKZM_WW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_KOMFKZM_WW-DATBI, sy-vline,
WA_KOMFKZM_WW-CCNAME, sy-vline,
WA_KOMFKZM_WW-AUTWR, sy-vline,
WA_KOMFKZM_WW-CCWAE, sy-vline,
WA_KOMFKZM_WW-AUDAT, sy-vline,
WA_KOMFKZM_WW-AUTIM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_KOMFKZM_WW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_KOMFKZM_WW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_KOMFKZM_WW INTO WA_KOMFKZM_WW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CCACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_KOMFKZM_WW-CCACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_KOMFKZM_WW-CCACT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_KOMFKZM_WW_STR,
TYPZM TYPE STRING,
CCINS TYPE STRING,
CCNUM TYPE STRING,
CCFOL TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
CCNAME TYPE STRING,
AUTWR TYPE STRING,
CCWAE TYPE STRING,
AUDAT TYPE STRING,
AUTIM TYPE STRING,
MERCH TYPE STRING,
TRMID TYPE STRING,
FAKWR TYPE STRING,
CCBEG TYPE STRING,
AUNUM TYPE STRING,
FKSAF TYPE STRING,
CSOUR TYPE STRING,
SETTL TYPE STRING,
AUTRA TYPE STRING,
LOCID TYPE STRING,
FLGAU TYPE STRING,
FPLNR_AK TYPE STRING,
FPLTR_AK TYPE STRING,
REACT TYPE STRING,
AUTWV TYPE STRING,
CCACT TYPE STRING,
CCALL TYPE STRING,
CCPRE TYPE STRING,
CCVAL TYPE STRING,
CCAUA TYPE STRING,
RCAVR TYPE STRING,
RCAVA TYPE STRING,
RCAVZ TYPE STRING,
RCRSP TYPE STRING,
CVVAL TYPE STRING,
CVVCT TYPE STRING,
CVVST TYPE STRING,
RTEXT TYPE STRING,
DUMMY TYPE STRING,
VCARD TYPE STRING,
RFCAUT TYPE STRING,
FNAUT_SETINIT TYPE STRING,
FNAUT_SETINFO TYPE STRING,END OF T_EKKO_STR. DATA: WA_KOMFKZM_WW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_KOMFKZM_WW_STR-TYPZM sy-vline
WA_KOMFKZM_WW_STR-CCINS sy-vline
WA_KOMFKZM_WW_STR-CCNUM sy-vline
WA_KOMFKZM_WW_STR-CCFOL sy-vline
WA_KOMFKZM_WW_STR-DATAB sy-vline
WA_KOMFKZM_WW_STR-DATBI sy-vline
WA_KOMFKZM_WW_STR-CCNAME sy-vline
WA_KOMFKZM_WW_STR-AUTWR sy-vline
WA_KOMFKZM_WW_STR-CCWAE sy-vline
WA_KOMFKZM_WW_STR-AUDAT sy-vline
WA_KOMFKZM_WW_STR-AUTIM sy-vline
WA_KOMFKZM_WW_STR-MERCH sy-vline
WA_KOMFKZM_WW_STR-TRMID sy-vline
WA_KOMFKZM_WW_STR-FAKWR sy-vline
WA_KOMFKZM_WW_STR-CCBEG sy-vline
WA_KOMFKZM_WW_STR-AUNUM sy-vline
WA_KOMFKZM_WW_STR-FKSAF sy-vline
WA_KOMFKZM_WW_STR-CSOUR sy-vline
WA_KOMFKZM_WW_STR-SETTL sy-vline
WA_KOMFKZM_WW_STR-AUTRA sy-vline
WA_KOMFKZM_WW_STR-LOCID sy-vline
WA_KOMFKZM_WW_STR-FLGAU sy-vline
WA_KOMFKZM_WW_STR-FPLNR_AK sy-vline
WA_KOMFKZM_WW_STR-FPLTR_AK sy-vline
WA_KOMFKZM_WW_STR-REACT sy-vline
WA_KOMFKZM_WW_STR-AUTWV sy-vline
WA_KOMFKZM_WW_STR-CCACT sy-vline
WA_KOMFKZM_WW_STR-CCALL sy-vline
WA_KOMFKZM_WW_STR-CCPRE sy-vline
WA_KOMFKZM_WW_STR-CCVAL sy-vline
WA_KOMFKZM_WW_STR-CCAUA sy-vline
WA_KOMFKZM_WW_STR-RCAVR sy-vline
WA_KOMFKZM_WW_STR-RCAVA sy-vline
WA_KOMFKZM_WW_STR-RCAVZ sy-vline
WA_KOMFKZM_WW_STR-RCRSP sy-vline
WA_KOMFKZM_WW_STR-CVVAL sy-vline
WA_KOMFKZM_WW_STR-CVVCT sy-vline
WA_KOMFKZM_WW_STR-CVVST sy-vline
WA_KOMFKZM_WW_STR-RTEXT sy-vline
WA_KOMFKZM_WW_STR-DUMMY sy-vline
WA_KOMFKZM_WW_STR-VCARD sy-vline
WA_KOMFKZM_WW_STR-RFCAUT sy-vline
WA_KOMFKZM_WW_STR-FNAUT_SETINIT sy-vline
WA_KOMFKZM_WW_STR-FNAUT_SETINFO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.