ABAP Select data from SAP table JVA_JOINTVENT_PROJ_SUSP_DMC_TS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP JVA_JOINTVENT_PROJ_SUSP_DMC_TS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to JVA_JOINTVENT_PROJ_SUSP_DMC_TS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the JVA_JOINTVENT_PROJ_SUSP_DMC_TS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_JVA_JOINTVENT_PROJ_SUSP_DMC_TS TYPE STANDARD TABLE OF JVA_JOINTVENT_PROJ_SUSP_DMC_TS,
      WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS TYPE JVA_JOINTVENT_PROJ_SUSP_DMC_TS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <JVA_JOINTVENT_PROJ_SUSP_DMC_TS> TYPE JVA_JOINTVENT_PROJ_SUSP_DMC_TS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_JVA_JOINTVENT_PROJ_SUSP_DMC_TS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM JVA_JOINTVENT_PROJ_SUSP_DMC_TS
  INTO TABLE IT_JVA_JOINTVENT_PROJ_SUSP_DMC_TS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM JVA_JOINTVENT_PROJ_SUSP_DMC_TS
*  INTO TABLE @DATA(IT_JVA_JOINTVENT_PROJ_SUSP_DMC_TS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_JVA_JOINTVENT_PROJ_SUSP_DMC_TS INDEX 1 INTO DATA(WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_JVA_JOINTVENT_PROJ_SUSP_DMC_TS ASSIGNING <JVA_JOINTVENT_PROJ_SUSP_DMC_TS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<JVA_JOINTVENT_PROJ_SUSP_DMC_TS>-SENDER_TECHNICAL_ID = 1.
<JVA_JOINTVENT_PROJ_SUSP_DMC_TS>-ACTIVITY = 1.
<JVA_JOINTVENT_PROJ_SUSP_DMC_TS>-MANDT = 1.
<JVA_JOINTVENT_PROJ_SUSP_DMC_TS>-BUKRS = 1.
<JVA_JOINTVENT_PROJ_SUSP_DMC_TS>-PROJECT = 1.
ENDLOOP.

LOOP AT IT_JVA_JOINTVENT_PROJ_SUSP_DMC_TS INTO WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PJSUSFLAG, sy-vline,
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROSUSPER, sy-vline,
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROSUSYEAR, sy-vline,
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PJUSUSFLAG, sy-vline,
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROUSUSPER, sy-vline,
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROUSUSYER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_JVA_JOINTVENT_PROJ_SUSP_DMC_TS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_JVA_JOINTVENT_PROJ_SUSP_DMC_TS INTO WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ABPSP, internal->external for field PROJECT CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROJECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field PROSUSYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROSUSYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROSUSYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field PROUSUSYER CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROUSUSYER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS-PROUSUSYER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR,
SENDER_TECHNICAL_ID TYPE STRING,
ACTIVITY TYPE STRING,
MANDT TYPE STRING,
BUKRS TYPE STRING,
PROJECT TYPE STRING,
PJSUSFLAG TYPE STRING,
PROSUSPER TYPE STRING,
PROSUSYEAR TYPE STRING,
PJUSUSFLAG TYPE STRING,
PROUSUSPER TYPE STRING,
PROUSUSYER TYPE STRING,END OF T_EKKO_STR. DATA: WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-SENDER_TECHNICAL_ID sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-ACTIVITY sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-MANDT sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-BUKRS sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-PROJECT sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-PJSUSFLAG sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-PROSUSPER sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-PROSUSYEAR sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-PJUSUSFLAG sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-PROUSUSPER sy-vline
WA_JVA_JOINTVENT_PROJ_SUSP_DMC_TS_STR-PROUSUSYER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.