ABAP Select data from SAP table JITHD_OIT_OCO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP JITHD_OIT_OCO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to JITHD_OIT_OCO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the JITHD_OIT_OCO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_JITHD_OIT_OCO TYPE STANDARD TABLE OF JITHD_OIT_OCO,
      WA_JITHD_OIT_OCO TYPE JITHD_OIT_OCO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <JITHD_OIT_OCO> TYPE JITHD_OIT_OCO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_JITHD_OIT_OCO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM JITHD_OIT_OCO
  INTO TABLE IT_JITHD_OIT_OCO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM JITHD_OIT_OCO
*  INTO TABLE @DATA(IT_JITHD_OIT_OCO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_JITHD_OIT_OCO INDEX 1 INTO DATA(WA_JITHD_OIT_OCO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_JITHD_OIT_OCO ASSIGNING <JITHD_OIT_OCO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<JITHD_OIT_OCO>-MANDT = 1.
<JITHD_OIT_OCO>-JINUM = 1.
<JITHD_OIT_OCO>-CUSTO = 1.
<JITHD_OIT_OCO>-PRODN = 1.
<JITHD_OIT_OCO>-SEQNR = 1.
ENDLOOP.

LOOP AT IT_JITHD_OIT_OCO INTO WA_JITHD_OIT_OCO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_JITHD_OIT_OCO-VETYP, sy-vline,
WA_JITHD_OIT_OCO-VEHID, sy-vline,
WA_JITHD_OIT_OCO-TEXHD, sy-vline,
WA_JITHD_OIT_OCO-SSPEZ, sy-vline,
WA_JITHD_OIT_OCO-NACHB, sy-vline,
WA_JITHD_OIT_OCO-ABTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_JITHD_OIT_OCO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_JITHD_OIT_OCO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_JITHD_OIT_OCO INTO WA_JITHD_OIT_OCO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_JITHD_OIT_OCO-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JITHD_OIT_OCO-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PKNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_JITHD_OIT_OCO-PKNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JITHD_OIT_OCO-PKNUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_JITHD_OIT_OCO_STR,
MANDT TYPE STRING,
JINUM TYPE STRING,
CUSTO TYPE STRING,
PRODN TYPE STRING,
SEQNR TYPE STRING,
VETYP TYPE STRING,
VEHID TYPE STRING,
TEXHD TYPE STRING,
SSPEZ TYPE STRING,
NACHB TYPE STRING,
ABTYP TYPE STRING,
ARCHI TYPE STRING,
DDATA TYPE STRING,
RANGE TYPE STRING,
OUTPO TYPE STRING,
OUTID TYPE STRING,
POSID TYPE STRING,
CNTRL TYPE STRING,
LIFNR TYPE STRING,
GRPIN TYPE STRING,
GRIND TYPE STRING,
INTST TYPE STRING,
INDAT TYPE STRING,
CRDAT TYPE STRING,
RDATE TYPE STRING,
FLAGS TYPE STRING,
TEXIT TYPE STRING,
JCPOS TYPE STRING,
PKNUM TYPE STRING,
QUANT TYPE STRING,
GRDON TYPE STRING,
ANLIE TYPE STRING,
TEXCO TYPE STRING,END OF T_EKKO_STR. DATA: WA_JITHD_OIT_OCO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_JITHD_OIT_OCO_STR-MANDT sy-vline
WA_JITHD_OIT_OCO_STR-JINUM sy-vline
WA_JITHD_OIT_OCO_STR-CUSTO sy-vline
WA_JITHD_OIT_OCO_STR-PRODN sy-vline
WA_JITHD_OIT_OCO_STR-SEQNR sy-vline
WA_JITHD_OIT_OCO_STR-VETYP sy-vline
WA_JITHD_OIT_OCO_STR-VEHID sy-vline
WA_JITHD_OIT_OCO_STR-TEXHD sy-vline
WA_JITHD_OIT_OCO_STR-SSPEZ sy-vline
WA_JITHD_OIT_OCO_STR-NACHB sy-vline
WA_JITHD_OIT_OCO_STR-ABTYP sy-vline
WA_JITHD_OIT_OCO_STR-ARCHI sy-vline
WA_JITHD_OIT_OCO_STR-DDATA sy-vline
WA_JITHD_OIT_OCO_STR-RANGE sy-vline
WA_JITHD_OIT_OCO_STR-OUTPO sy-vline
WA_JITHD_OIT_OCO_STR-OUTID sy-vline
WA_JITHD_OIT_OCO_STR-POSID sy-vline
WA_JITHD_OIT_OCO_STR-CNTRL sy-vline
WA_JITHD_OIT_OCO_STR-LIFNR sy-vline
WA_JITHD_OIT_OCO_STR-GRPIN sy-vline
WA_JITHD_OIT_OCO_STR-GRIND sy-vline
WA_JITHD_OIT_OCO_STR-INTST sy-vline
WA_JITHD_OIT_OCO_STR-INDAT sy-vline
WA_JITHD_OIT_OCO_STR-CRDAT sy-vline
WA_JITHD_OIT_OCO_STR-RDATE sy-vline
WA_JITHD_OIT_OCO_STR-FLAGS sy-vline
WA_JITHD_OIT_OCO_STR-TEXIT sy-vline
WA_JITHD_OIT_OCO_STR-JCPOS sy-vline
WA_JITHD_OIT_OCO_STR-PKNUM sy-vline
WA_JITHD_OIT_OCO_STR-QUANT sy-vline
WA_JITHD_OIT_OCO_STR-GRDON sy-vline
WA_JITHD_OIT_OCO_STR-ANLIE sy-vline
WA_JITHD_OIT_OCO_STR-TEXCO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.