ABAP Select data from SAP table JBP_DATA_FOR_ECATT_CHECK_W into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP JBP_DATA_FOR_ECATT_CHECK_W table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to JBP_DATA_FOR_ECATT_CHECK_W. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the JBP_DATA_FOR_ECATT_CHECK_W table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_JBP_DATA_FOR_ECATT_CHECK_W TYPE STANDARD TABLE OF JBP_DATA_FOR_ECATT_CHECK_W,
      WA_JBP_DATA_FOR_ECATT_CHECK_W TYPE JBP_DATA_FOR_ECATT_CHECK_W,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <JBP_DATA_FOR_ECATT_CHECK_W> TYPE JBP_DATA_FOR_ECATT_CHECK_W.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_JBP_DATA_FOR_ECATT_CHECK_W.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM JBP_DATA_FOR_ECATT_CHECK_W
  INTO TABLE IT_JBP_DATA_FOR_ECATT_CHECK_W.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM JBP_DATA_FOR_ECATT_CHECK_W
*  INTO TABLE @DATA(IT_JBP_DATA_FOR_ECATT_CHECK_W2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_JBP_DATA_FOR_ECATT_CHECK_W INDEX 1 INTO DATA(WA_JBP_DATA_FOR_ECATT_CHECK_W2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_JBP_DATA_FOR_ECATT_CHECK_W ASSIGNING <JBP_DATA_FOR_ECATT_CHECK_W>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<JBP_DATA_FOR_ECATT_CHECK_W>-IF_EQUNR = 1.
<JBP_DATA_FOR_ECATT_CHECK_W>-IF_ZWNUMMER = 1.
<JBP_DATA_FOR_ECATT_CHECK_W>-IF_ADATREAL = 1.
<JBP_DATA_FOR_ECATT_CHECK_W>-IF_ATIMREAL = 1.
<JBP_DATA_FOR_ECATT_CHECK_W>-IF_ADAT = 1.
ENDLOOP.

LOOP AT IT_JBP_DATA_FOR_ECATT_CHECK_W INTO WA_JBP_DATA_FOR_ECATT_CHECK_W.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ATIM, sy-vline,
WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ZWSTAND, sy-vline,
WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ABLESGR_NEUTRAL, sy-vline,
WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ANLAGE, sy-vline,
WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ABLESGR_ANLAGE, sy-vline,
WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ABLBELNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_JBP_DATA_FOR_ECATT_CHECK_W you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_JBP_DATA_FOR_ECATT_CHECK_W TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_JBP_DATA_FOR_ECATT_CHECK_W INTO WA_JBP_DATA_FOR_ECATT_CHECK_W. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field IF_EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HH_MM, internal->external for field IF_ATIMREAL CALL FUNCTION 'CONVERSION_EXIT_HH_MM_OUTPUT' EXPORTING input = WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ATIMREAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ATIMREAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HH_MM, internal->external for field IF_ATIM CALL FUNCTION 'CONVERSION_EXIT_HH_MM_OUTPUT' EXPORTING input = WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ATIM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ATIM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field IF_ANLAGE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ANLAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ANLAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field IF_ABLBELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ABLBELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_JBP_DATA_FOR_ECATT_CHECK_W-IF_ABLBELNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_JBP_DATA_FOR_ECATT_CHECK_W_STR,
IF_EQUNR TYPE STRING,
IF_ZWNUMMER TYPE STRING,
IF_ADATREAL TYPE STRING,
IF_ATIMREAL TYPE STRING,
IF_ADAT TYPE STRING,
IF_ATIM TYPE STRING,
IF_ZWSTAND TYPE STRING,
IF_ABLESGR_NEUTRAL TYPE STRING,
IF_ANLAGE TYPE STRING,
IF_ABLESGR_ANLAGE TYPE STRING,
IF_ABLBELNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_JBP_DATA_FOR_ECATT_CHECK_W_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_EQUNR sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ZWNUMMER sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ADATREAL sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ATIMREAL sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ADAT sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ATIM sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ZWSTAND sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ABLESGR_NEUTRAL sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ANLAGE sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ABLESGR_ANLAGE sy-vline
WA_JBP_DATA_FOR_ECATT_CHECK_W_STR-IF_ABLBELNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.