ABAP Select data from SAP table J_7LM11_V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP J_7LM11_V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to J_7LM11_V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the J_7LM11_V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_J_7LM11_V TYPE STANDARD TABLE OF J_7LM11_V,
      WA_J_7LM11_V TYPE J_7LM11_V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <J_7LM11_V> TYPE J_7LM11_V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_J_7LM11_V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM J_7LM11_V
  INTO TABLE IT_J_7LM11_V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM J_7LM11_V
*  INTO TABLE @DATA(IT_J_7LM11_V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_J_7LM11_V INDEX 1 INTO DATA(WA_J_7LM11_V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_J_7LM11_V ASSIGNING <J_7LM11_V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<J_7LM11_V>-MANDT = 1.
<J_7LM11_V>-MATNR = 1.
<J_7LM11_V>-VPGRP = 1.
<J_7LM11_V>-LAND1 = 1.
<J_7LM11_V>-VRKME = 1.
ENDLOOP.

LOOP AT IT_J_7LM11_V INTO WA_J_7LM11_V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_J_7LM11_V-ENTNR, sy-vline,
WA_J_7LM11_V-MOBJKEY, sy-vline,
WA_J_7LM11_V-VRSIO, sy-vline,
WA_J_7LM11_V-ENTNA, sy-vline,
WA_J_7LM11_V-MEKEY, sy-vline,
WA_J_7LM11_V-DATAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_J_7LM11_V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_J_7LM11_V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_J_7LM11_V INTO WA_J_7LM11_V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_J_7LM11_V-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LM11_V-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_J_7LM11_V-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LM11_V-VRKME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_J_7LM11_V-ENTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_J_7LM11_V-ENTNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_J_7LM11_V_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
VPGRP TYPE STRING,
LAND1 TYPE STRING,
VRKME TYPE STRING,
ENTNR TYPE STRING,
MOBJKEY TYPE STRING,
VRSIO TYPE STRING,
ENTNA TYPE STRING,
MEKEY TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,END OF T_EKKO_STR. DATA: WA_J_7LM11_V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_J_7LM11_V_STR-MANDT sy-vline
WA_J_7LM11_V_STR-MATNR sy-vline
WA_J_7LM11_V_STR-VPGRP sy-vline
WA_J_7LM11_V_STR-LAND1 sy-vline
WA_J_7LM11_V_STR-VRKME sy-vline
WA_J_7LM11_V_STR-ENTNR sy-vline
WA_J_7LM11_V_STR-MOBJKEY sy-vline
WA_J_7LM11_V_STR-VRSIO sy-vline
WA_J_7LM11_V_STR-ENTNA sy-vline
WA_J_7LM11_V_STR-MEKEY sy-vline
WA_J_7LM11_V_STR-DATAB sy-vline
WA_J_7LM11_V_STR-DATBI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.